background image

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

PC 111

Catalog No. 533-352

Printed in U.S.A.

Form 33CS-35SI

Pg 1

105

9-00

Replaces: New

Book 1

4

Tab

11a 13a

Installation, Start-Up and

Operating Instructions

Part Numbers 33CS250-FS

and 33CS220-FS

CONTENTS

Page

SAFETY CONSIDERATIONS

. . . . . . . . . . . . . . . . . . . . . . 1

GENERAL

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7

Select Thermostat Location

. . . . . . . . . . . . . . . . . . . . . . 2

Install Thermostat (With Junction Box)

. . . . . . . . . . . 2

Install Thermostat (Without Junction Box)

. . . . . . . 3

Set Clock

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Configure Advanced Setup

. . . . . . . . . . . . . . . . . . . . . . . 4

Install Accessories

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Program Thermostat Schedules

. . . . . . . . . . . . . . . . . . 6

Factory Defaults

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Calibrate Sensor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Check Thermostat Operation

. . . . . . . . . . . . . . . . . . . . . 7

Final Checklist

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

OPERATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9

Auto-Changeover

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Two-Stage Operation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Clock Backup

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Fan Operation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Emergency Heat

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Electric Heat

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Holiday Mode

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Remote Temperature Sensor

. . . . . . . . . . . . . . . . . . . . . 8

Keypad Lock

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Dry Contact Switch/External Control

. . . . . . . . . . . . . 8

10-Watt Resistor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Outside Temperature Sensor (Optional)

. . . . . . . . . . 9

TROUBLESHOOTING

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

SAFETY CONSIDERATIONS

Read and follow manufacturer instructions carefully. Fol-

low all local electrical codes during installation. All wiring
must conform to local and national electrical codes. Improper
wiring or installation may damage thermostat.

Recognize safety information. This is the safety alert sym-

bol

. When the safety alert symbol is present on equipment

or in the instruction manual, be alert to the potential for person-
al injury.

Understand the signal words DANGER, WARNING, and

CAUTION. These words are used with the safety alert symbol.
DANGER identifies the most serious hazards which will result
in severe personal injury or death. WARNING signifies a haz-
ard which could result in personal injury or death. CAUTION
is used to identify unsafe practices which would result in minor
personal injury or property damage.

GENERAL

The commercial, 7-day, programmable thermostats are

wall-mounted, low-voltage thermostats which maintain room
temperature by controlling the operation of an HVAC (Heating,
Ventilation, and Air Conditioning) system. Separate heating
and cooling set points and auto-changeover capability allow 4
different programming time periods for energy savings.

All thermostats allow up to 4 time/temperature settings to

be programmed per 24-hour period. Each thermostat stores
programs for 7 independent days. Batteries are not required.
During power interruption the internal NEVER-LOST™
memory stores programmed schedules for an unlimited
amount of time while the clock continues to run for at least
48 hours.

The thermostat can be configured to accept several different

equipment configurations, including heat pump operation.
NOTE: The thermostat is not factory-configured for use in heat
pump applications. The advanced setup must be performed to
configure the thermostat for use with heat pump units.
NOTE: The 33CS250-FS thermostats have wiring connections
for a remote room sensor and dry contacts. The 33CS220-FS
thermostats do not have these connections.

PACKAGE CONTENTS

IMPORTANT: Read entire instructions before starting
the installation.

ITEM

QUANTITY

Thermostat

1

Cutout Template

1

1-in. Screws (Junction Box Installation)

2

1

1

/

2

-in. Self-Tapping Screws

(Non-Junction Box Installation)

2

Plastic Tabs

2

Power Resistor (270 ohm, 10 Watt)

1

Debonair®

33CS

Flush-Mounted FlatStat

Commercial Programmable Thermostat

Содержание DEBONAIR 33CS

Страница 1: ...most serious hazards which will result in severe personal injury or death WARNING signifies a haz ard which could result in personal injury or death CAUTION is used to identify unsafe practices which would result in minor personal injury or property damage GENERAL The commercial 7 day programmable thermostats are wall mounted low voltage thermostats which maintain room temperature by controlling t...

Страница 2: ... is a hazardous waste and must be disposed of properly 3 Install 2 x 4 in junction box field supplied in wall See Fig 1 4 Route thermostat wires through back of junction box Re move outer sheath from wires for added flexibility Standard solid or multi conductor thermostat wire should be used from the thermostat to the unit Size and length considerations are as follows for a maximum distance from u...

Страница 3: ...o prevent adjacent wires from shorting together Match and connect wires to terminals on the thermostat See Fig 2 and Table 1 5 Attach thermostat to wall On paneling installations see Fig 4 a Push thermostat into hole in wall Make sure tabs on paneling match up with mounting holes on thermostat b Using two 11 2 in self tapping screws attach thermostat to wall Make sure thermostat cover is flush aga...

Страница 4: ...ing UP ARROW or DOWN AR ROW To ensure the schedules are properly followed make sure that AM or PM is correct for the time chosen When the correct time is shown press the Mode button to modify the day of the week The current day will blink on and off Press the UP ARROW and DOWN ARROW buttons until the correct day is shown Press the and hold the Mode and Override buttons at the same time again to ex...

Страница 5: ...an application The soft start staggers the start up times of the units in the event of power loss and restart Each unit should be assigned a unit ID number The 30 second delay time is multiplied the unit ID number to get the total soft start delay time for each unit For example if the unit ID number is 10 set the Soft Start function to 10 the start up delay time is 30 seconds x 10 300 seconds 5 mi...

Страница 6: ...wer the cooling set point until the desired tem perature is shown The range of acceptable values is 35 to 99 F 1 to 37 C or OF no unoccupied cooling To configure the Unoccupied Cooling set point to OF press the UP ARROW button until 99 F is displayed Press the UP ARROW button again to display OF Press the Mode button to continue 5 The heating set point for Unoccupied will be displayed Use the UP A...

Страница 7: ...Press the UP or DOWN ARROW buttons until the flashing number equals room temperature 4 Press the Mode button again to return to normal operation Check Thermostat Operation To check thermo stat operation perform the following procedure 1 Press the Mode button repeatedly until the Heat icon ap pears on the display The thermostat is now in Heating mode 2 Press the UP ARROW button until the heating se...

Страница 8: ...ore the remaining config ured days have passed press the Mode and UP ARROW but tons simultaneously to enter into Programming mode Press the Override button to enter into Holiday Programming mode Press the DOWN ARROW to set the number of days to zero Holiday mode will be disabled Remote Temperature Sensor 33CS250 FS Only A remote temperature sensor is available to read the temperature from a space ...

Страница 9: ...check the unit wiring diagram See Fig 10 SOFT START When multiple thermostats are controlled by the same external device a Soft Start option can be used to stagger the turn on times of the HVAC equipment This feature may cause a delay in operation after entering Unoccupied mode 10 Watt Resistor A 10 watt 270 ohm resistor is pro vided with the thermostat This resistor should only be used in applica...

Страница 10: ...ac is not present replace the thermostat When using 4 wires R G W Y the cooling equipment tries repeatedly to turn on but cannot At times the display dims or disappears There is not enough power available Connect a 270 ohm 10 watt power resistor supplied with thermostat at the air conditioning equipment between terminals W and C non heat pump applications only When using 4 wires R G W Y the heatin...

Страница 11: ......

Страница 12: ...inue or change at any time specifications or designs without notice and without incurring obligations PC 111 Catalog No 533 352 Printed in U S A Form 33CS 35SI Pg 12 105 9 00 Replaces New Book 1 4 Tab 11a 13a Copyright 2000 Carrier Corporation ...