Carrier DC INVERTER FREE Скачать руководство пользователя страница 5

Do not touch the heat exchanger fins. 

These fins are sharp and could result in cutting injuries.

Do not place items which might be damaged by moisture 
under the indoor unit. 

Condensation may form if the humidity is above 80%, the 
drain outlet is blocked or the filter is polluted. 

After a long use, check the unit stand and fitting for 
damage.

 

If damaged, the unit may fall and result in injury.

To avoid oxygen deficiency, ventilate the room 
sufficiently if equipment with burner is used together 
with the air conditioner.

Arrange the drain hose to ensure smooth drainage.

Incomplete drainage may cause wetting of the building, 
furniture etc.

Never touch the internal parts of the controller.

 

Do not remove the front panel. Some parts inside are 
dangerous to touch, and a machine trouble may happen.

Do not operate the air conditioner with a wet hand. 

An electric shock may happen. 

Never expose little children, plants or animals directly to 
the air flow. 

Adverse influence to little children, animals and plants may 
result.

Do not allow a child to mount on the outdoor unit or 
avoid placing any object on it.

 

Falling or tumbling may result in injury.

Do not operate the air conditioner when using a room 
fumigation - type insecticide. 

Failure to observe could cause the chemicals to become 
deposited in the unit, which could endanger the health of 
those who are hypersensitive to chemicals.

Do not place appliances which produce open fire in 
places exposed to the air flow from the unit or under the 
indoor unit.

 

It may cause incomplete combuston or deformation of the unit 
due to the heat.

Do not install the air conditioner at any place where 
flammable gas may leak out. 

If the gas leaks out and stays around the air conditioner, a fire 
may break out. 

This appliance can be used by children age from 8 years 
and above and persons with reduced physical,sensory or 
mental capabilities or lack of experience and knowledge 
if they have been given supervision or instruction 
concerning use of the appliance in a safe way and 
understand the hazards involved,children should not play 
with This appliance.Cleaning and user maintenance 
should not  be made by children without supervision.

When capacity of indoor unit greater than the sum of 
100%, capacity of indoor unit will be attenuated.

When capacity of indoor unit greater than or equal to the 
sum of 120%, in order to ensure the effectiveness of 
machine, and then try to open the indoor units at 
different time.

The outdoor unit window-shades should be periodic 
cleaning in case of being jammed.

This window-shapes is heat dissipation outlet of components, if being 
jammed will cause the components shorten their service life spans because
of overheated for a long time. 

The air conditioner consists of the indoor unit, the 
outdoor unit, the connecting pipe and the remote 
controller.

(see Fig.1)

2

owner's manual

Force Cooling Control 

Force cooling control of outdoor unit be pressed once that a order 
to force cooling in indoor unit. When the frequency of outdoor unit 
change to 62Hz and then running it; indoor fan run in high speed. 
Press the button again will exit the Force Cooling Control.   

Display function

Force Cooling Control

2.    PARTS NAMES

Fig.2-1

MAIN BOARD

Force cooling 
control Button sw1

Display control button sw2

(OUTDOOR UNIT)

sw1

sw2

SW2 on the main control board of outdoor unit is the point 
inspection function button (as shown in Figure 2-1). Pressing this 
button once displays the first parameter of the digital pipe in the 
main control board.
Additional button presses will display other parameters following 
the sequence shown in Table 2-1.

Table 2-1(20kW)

The temperature of refrigerant circuit will be high, please 
keep the interconnection cable away from the copper tube.

5.Poor environmental conditions,  the appliance should be 
maintained a month and a half or so; If the environment con-
dition is good, may be extended appropriately maintenance 
cycle. 

Current frequency

Local capacity of outdoor units

Total capacity requirements of outdoor 
units

Total  requirements of  outdoor units 
corrected capacity

Operating mode

Operating FAN speed and FAN grade

T2B/T2 average temperature

T3 pipe temperature 

T4 environment temperature

Inverter exhaust temperature

Non-inverter exhaust temperature
 (reserved)

Heat dissipator surface temperature
 (reserved)

Electronic expansion valve aperture

Inverter input current

Non-inverter input current

Exhaust pressure (reserved)

Priority mode

Indoor unit quantity

Working indoor unit quantity

Last fault or protection code

--

Normal display

Displayed Content

0--

1--

2--

3--

4--

5--

7--

8--

9--

0--

1--

2--

3--

4--

5--

6--

7--

8--

9--

6--

Sequence

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

0--

Program Version

Содержание DC INVERTER FREE

Страница 1: ...OWNER S MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference DC INVERTER FREE ...

Страница 2: ......

Страница 3: ...om the air conditioner you purchased depend on model The actual shape shall prevail NOTE This air conditioner comprises an indoor unit outdoor unit and a connection pipe Outdoor unit Air outlet 1 2 3 4 Air inlet Fixing support Refrigerant pipe connector 1 2 3 4 Fig 1 Indoor unit 5 5 Connection pipe ...

Страница 4: ...s service angent or similarly qualified person in order to avoid a hazard WARNING The safty precautions listed here are divided into two categories In either case important safty information is listed which must be read carefully CAUTION Failure to observe a caution may result in injury or damage to the equipment Failure to observe a warning may result in death The appliance shall be installed in ...

Страница 5: ...pacity of indoor unit will be attenuated When capacity of indoor unit greater than or equal to the sum of 120 in order to ensure the effectiveness of machine and then try to open the indoor units at different time The outdoor unit window shades should be periodic cleaning in case of being jammed This window shapes is heat dissipation outlet of components if being jammed will cause the components s...

Страница 6: ...en the Air Conditioner is to be directed running compulsively When the Protection Equipment is activated the Operation Indicator still lights while the Air Conditioner is not running But the Check Indicatior Lights Ƶ NOTE 4 2 About power cut If power is cut during operation stop all the operation immediately Power comes again The lamp on the display panel of indoor unit flashes And then unit will ...

Страница 7: ...operation the fan motor in the outdoor unit may stop running under high temperature During Fan Operation if other Indoor Units are running on Heating Mode the fan may stop in order to prevent sending heat wind 4 7 Defrost in the heating operation During heating operation outdoor unit sometimes will frost To increase efficiency the unit will start defrosting automatically about 2 10 minutes and the...

Страница 8: ...tion Outdoor input current protection COMM Fault between DSP and chip COMM Fault between communication chip and main chip P1 P2 P3 Compressor discharge high protection Outdoor condenser high temperature protection Evaporator high temperature protection Inverter module protection P4 P5 P6 23 24 Typhoon protection Recovery Mode Recoverable Recoverable Irrecoverable Irrecoverable Recoverable Recovera...

Страница 9: ... is heard when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the system stops after heating operation Expansion and contraction of plastic parts caused by temperature change make this noise Symptom 4 2 Indoor unit outdoor unit A continuous low hissing sound is heard when the s...

Страница 10: ...nit and indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for the comeback of power Switch on the power ReplLocation Replace the batterises or check the controller Set the temperature properly...

Страница 11: ... is pressed Check whether the signal transmitter of the remote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse o...

Страница 12: ......