5. INSTALLING YOUR CO ALARM:
CAUTION: This alarm should be installed by a
competent person.
The installation of this device should not be
used as a substitute for proper installation, use
and maintenance of fuel burning appliances,
including appropriate ventilation and exhaust
systems.
It does not replace a smoke alarm.
Installation with screw and plug:
Detach the alarm from the mounting base by twisting
counter clockwise.
Use the mounting base to mark up horizontally the
screw holes on the wall.
Attach the alarm by twisting clockwise.
Please note: The label in the product must not be
removed as it contains important information regard-
ing the product.
6.
TEST FUNCTION:
After installation and at least once per quarter, test
your alarm to make sure it is operating correctly.
It is recommended to check visually every week if the
green LED flashes correctly (every minute)
When the top button is pressed the alarm sounder
will sound, and when the button is released, the
alarm will make a self-test of the sensor and battery
for approximately 9 seconds. During this delay the
three LEDs will be flashed in sequence. The result
of the test will be indicated after the test has been
completed.
If the test passes, the green LED will emit for 3 sec.
If the test fails, a fault indication will be given (See
section 11).
After the test function is performed, the alarm will
need to recover for one minute before the next test
can be done (to allow the sensor chamber to re-set-
tle after the test current is applied).
The alarm will also do a self-test every 24 hour and
test the sensor for faulty sensor, drift or short circuit.
TIP: It is safe to cover the sound output hole with
your finger during the testing to minimize the sound
level emitted.
7.
OTHER INFORMATION:
Do not paint the alarm.
Disposal: Please dispose the product properly at the
end of life. This is electronic waste which should be
handled properly.
WARNING: Batteries shall not be exposed to exces-
sive heat such as shine, fire, or the like. Note the
local country regulations regarding installation.
WARNING: To prevent injury, this apparatus must be
permanently fixed to the ceiling/wall in accordance
with the installation instructions.
The CE mark affixed to this product confirms its
compliance with the European Directives which
apply to the product.
All Rights reserved: CAVIUS Aps assumes no re-
sponsibility for any errors, which may appear in this
manual. Furthermore, CAVIUS Aps reserves the
right to alter the hardware, software, and/or speci-
fications detailed herein at any time without notice,
and CAVIUS Aps does not make any com mitment
to update the information contained here in. All the
trademarks listed herein are owned by their respec-
tive owners. Copyright © CAVIUS Aps.
Developed by CAVIUS Aps Julsøvej 16, DK-8600
Manufactured in P.R.C.
Contact: CAVIUS Ltd, Edinburgh, Scotland, EH3 9DQ
Tel: +44(0)1506 896785, www.cavius.com
EN50291-1:2018
EN50291-2:2010
www.cavius.com
400148 rev3
Mark up screw holes with a pen
Use the enclosed screws
and plugs for installation
Peak ceiling
Minimum 30cm
from peak
Minimum 30cm
from wall
Wall
Ceiling
1 to 3m from fireplace
Wall