Carbon monoxide alarm device
Commercial reference : 4002-008
Developed by CAVIUS
This Cavius carbon monoxide (CO) alarm is de-
signed and tested to detect CO in private homes,
camping trailers, mobile homes and caravans. It will
provide early warning of the presence of CO.
PLEASE READ THE USER GUIDE
CAREFULLY BEFORE INSTALLATION AND
RETAIN FOR FUTURE USE.
SAFETY INSTRUCTIONS:
The device comes with a 3V lithium battery. Batteries
are to be handled with care and battery powered de-
vices should be kept out of reach of children. Do not
try to recharge or burn the batteries.
INFORMATION ABOUT CARBON MONOXIDE:
CO - Carbon monoxide - is known as the “silent killer”
because it is odourless, tasteless and colourless.
It can kill in few minutes.This apparatus may not
prevent the chronic effects of Carbon Monoxide ex-
posure.
All people are at risk for CO poisoning. Unborn ba-
bies, infants, the elderly, and people with chronic
heart disease, anemia, or respiratory problems are
generally more at risk than others. The apparatus will
not fully safeguard individuals at special risks
Breathing CO can cause headache, dizziness, vom-
iting, and nausea. If CO levels are high enough, you
may become unconscious or die.
1. TECHNICAL INFORMATION:
Diameter: 40mm Height: 38m.
Type of alarm: Type B apparatus with elec-
tro-chemical CO sensor.
Battery: Powered by a non-replaceable 3V CR123
Lith ium battery with 10-year life (included).
IMPORTANT: Do not try to replace the bat-
tery. Replace the product if the battery fails.
Product Life: 10 years after manufacturing date.
Complies to standards: EN50291-1:2018,
EN50270, EN50271, EN60335, RoHs, REACH.
Working condition: -10 to +40
0
C, 30 to 95% non-con-
densing.
Storage/Transport: -20 to +50
0
C, 10 to 95% non-
condensing.
Alarm Sound Level: The minimum sound level is 85
dB at 3 meters.
2. THE BEST AREAS TO INSTALL YOUR CO ALARM:
• Ideally, an apparatus should be installed in every
room containing a fuel-burning appliance.
• Near bedrooms and living areas.
• On each level of your home.
• 1 to 3 meter away from all fuel burning appliances.
• At eye level to allow optimum monitoring of the
in dicator lights.
• Install as High as possible as CO rises when mixed
with heat.
• You can fit on a wall but as high as possible.
3. AREAS WHERE NOT TO INSTALL CO ALARMS:
• In an enclosed space (for example in a cupboard or
behind a curtain).
• Where it can be obstructed (for example by
furniture).
• Directly above a sink.
• Next to a door or window.
• Next to an extractor fan.
• Next to an air vent or other similar ventilation
openings.
• In an area where the temperature may drop below -10
°C or exceed 40 °C.
• Where dirt and dust may block the sensor.
• In a damp or humid location.
• In the immediate vicinity of a cooking appliance.
4. PLACEMENT:
The CO alarm is designed to be installed on the wall
or a ceiling.
UK
INSTALLATION
G U I D E
Sounder
Yellow LED
Fault indicator
Green LED
Power indicator
Test/ hush
button
Mounting
base
Red LED
Alarm indicator
Siting of CO alarms
CO
Minimum 15cm from ceiling
Wall
Ceiling
Minimum 1,20m to 1,50m from the floor
Floor