
AGAGC9PNS01B Gas Conversion Kit, Propane to Natural: Installation Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
2
This instruction covers the installation of gas conversion kit to convert
the following furnaces from propane gas usage to natural gas usage.
NOTE: See appropriate sections for your furnace type.
Table 1 – Kit Contents
SINGLE-STAGE GAS VALVE
Condensing Furnaces with 40,000 to 140,000 BTUH (not all models
have 140,000 BTUH) gas input rates and a.) Single-Stage, 4-Way
Multipoise, Hot Surface Ignition with PSC blower motor or b.)
Single-Stage gas valve with Fixed-Speeds Constant Torque ECM (FCT)
blower motor.
TWO-STAGE & MODULATING GAS VALVE
Condensing Furnaces with 40,000 through 120,000 BTUH gas input rate
and a.) Modulating gas valve with Variable-Speed Constant Airflow
ECM (VCA), b.) Two-Stage gas valve with Variable-Speed Constant
Airflow ECM (VCA), or c.) Two-Stage gas valve with Variable-Speed
Constant Torque ECM (VCT) blower motor.
DESCRIPTION AND USAGE
This kit is designed for use in the furnaces listed in
or
,
see
for kit contents. To accommodate many different furnace
models, more parts are shipped in kit than will be needed to complete
conversion. When installation is complete, discard extra parts.
SINGLE-STAGE CONDENSING FURNACES
Table 2 – Single Stage Model Numbers
* Except 26,000 BTUH models.
TWO-STAGE & MODULATING CONDENSING
FURNACES
Table 3 – Two-Stage & Modulating Model Numbers
INSTALLATION
1. Set room thermostat to lowest setting or “OFF”
2. Disconnect power at external disconnect, fuse or circuit breaker.
3. Turn off gas at external shut-off or gas meter.
4. Remove outer doors and set aside.
5. Turn electric switch on gas valve to OFF.
A190014
Fig. 1 – Representative Furnace Drawing
MANIFOLD/ORIFICE/BURNER REMOVAL
NOTE:
Use a back-up wrench on the gas valve to prevent the valve
from rotating on the manifold or damaging the mounting to the burner
box.
1. Disconnect the gas pipe from gas valve and remove pipe from the
.
2. Disconnect the connector harness from gas valve Disconnect wires
from Hot Surface Igniter (HSI) and Flame Sensor.
WARNING
!
ELECTRICAL SHOCK, FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death or
property damage.
Before installing, modifying, or servicing system, main electrical
disconnect switch must be in the OFF position and install a lockout tag.
There may be more than one disconnect switch. Lock out and tag
switch with a suitable warning label. Verify proper operation after
servicing.
CAUTION
!
UNIT OPERATION HAZARD
Failure to follow this caution may result in unit damage or improper
operation.
Do NOT use this kit with furnaces with an input of 26,000 BTUH; the
unit will be severely over-fired. This could result in delayed ignition,
sooting or premature heat exchanger failure.
QUANTITY
DESCRIPTION
2
REGULATOR SPRINGS
4
ORIFICES (BAG ASSEMBLIES)
1
LABELS 346162-201 through 346162-209
1
PLUG, PIPE
1
INSTRUCTIONS
BEGINNING WITH:
59SP
59SC
912S
915S
922S
925S
926S
PG95S
PG95ES
PG92ES
(F/G)9MXE
(N/R)92ES
N96VSN
PG92S
R9MS
N9MS
WF(A/H/S)
(N/R)95ES
BEGINNING WITH:
59MN
59T(N/P)
PG96V
PG95X
987M
986T
925T
926T
(F/G)97C
(F/G)9MA
(F/G)9MV
(F/G)96V
(F/G)9MXT
(F/G)96C
CAUTION
!
UNIT OPERATION HAZARD
Failure to follow this caution may result in unit damage or improper
operation.
Label all wires prior to disconnection when servicing controls.
ATTENTION
!
D’EQUIPEMENT D’OPERATION
Toute erreur de câblage peut être une source de danger et de panne.
Lors des opérations d’entretien des commandes, étiqueter tous les fils
avant de les déconnecter.