2. Pressing the FAN button alternately selects AUTO or ON fan

operation. Fan annunciator displays the current selection.

3. Pressing the MODE button will select OFF, HEAT, COOL,

and AUTO. Heat pumps also have an EHEAT mode. Mode
annunciator displays the current selection.

4. Operation of other buttons is explained in the Homeowner’s

Guide.

Step 6—Check Thermostat Operation

SELECT HOLD

1. Press HOLD button to select

hold

feature. This will prevent

the setpoint from changing until the desired time/temperature
schedule is entered.

FAN OPERATION

1. Press FAN button, starting fan operation. Fan annunciator

switches from AUTO to ON.

2. Press FAN button, stopping fan operation. Fan annunciator

switches from ON to AUTO.

HEATING OPERATION

1. Press MODE button until HEAT is displayed under the mode

annunciator.

2. Press up button until LCD readout reads 10 degrees above

room temperature. Heating system should begin to operate
within 7 minutes.

COOLING OPERATION

1. Press MODE button until COOL is displayed under the mode

annunciator.

2. Press down button until LCD readout reads 10 degrees below

room temperature. Cooling system should begin to operate
within 7 minutes.

Step 7—Select Desired Operation

1. Press FAN button to select AUTO or ON position. Fan

annunciator displays current selection.

2. Press MODE button to select OFF, HEAT, COOL, AUTO.

Heat pumps will also have an EHEAT mode. Mode annun-
ciator displays current selection.

3. Press up or down buttons to select desired temperature.

4. If daily cycles are to be programmed now, refer to Homeown-

er’s Guide for programming instructions.

5. If thermostat has not been programmed, press HOLD button to

retain desired temperature setting.

NOTE:

If HOLD button is not left ON, temperature setting will

be lost until time/temperature program is entered.

Step 8—Checklist

1. Put away tools and instruments, and clean up debris.

2. Review Homeowner’s Guide with owner.

3. Leave literature packet with owner.

Fig. 2—Single-Speed Air Conditioner with Single-

Stage Furnace

A94217

24 VAC HOT

FAN

HEAT STAGE 1

COOL STAGE 1

N/A

N/A

R

G

W/W1

Y/Y2

O/W2

Y1/W2

R

G

W

Y

24 VAC COMM.

N/A

N/A

OUTDOOR

SENSOR

CONNECTION

C

B

L

S1

S2

C

Y

C

MODEL AC

THERMOSTAT

SINGLE-STAGE

FURNACE

SINGLE-SPEED

AIR CONDITIONER

Fig. 3—Single-Speed Air Conditioner with 2-Stage

or Variable-Speed Furnace

A94218

24 VAC HOT

FAN

HEAT STAGE 1

COOL STAGE 1

N/A

N/A

R

G

W/W1

Y/Y2

O/W2

Y1/W2

R

G

24 VAC COMM.

N/A

N/A

OUTDOOR

SENSOR

CONNECTION

C

B

L

S1

S2

C

Y

C

MODEL AC

THERMOSTAT

TWO-STAGE OR

VARIABLE-SPEED

FURNACE

SINGLE-SPEED

AIR CONDITIONER

See note 1

W/W1

Y/Y2

W2

3

Содержание A94134

Страница 1: ...ly HP 1 stage cool 2 stage heat for either HP or AC with 2 stage heat 2S 2 stage cool 2 stage heat for 2 speed AC systems or 2 stage cool 3 stage heat for 2 speed HP systems or 1 stage cool 4 stage heat for 1 speed HP with special 3 stage electric heat Use each only for its intended purpose See Table 1 INSTALLATION Step 1 Thermostat Location Thermostat should be mounted Approximately 5 ft 1 5m fro...

Страница 2: ... wires to the correct terminals of the thermostat connector See Table 1 and Fig 2 through 14 Both R and C must be connected for proper thermostat operation Improper wiring or installation may damage the thermostat Check to make sure wiring is correct before proceeding with installation or turning on unit 9 Push excess wiring into wall Seal hole in wall to prevent drafts 10 Snap hinge back together...

Страница 3: ...ed Operation 1 Press FAN button to select AUTO or ON position Fan annunciator displays current selection 2 Press MODE button to select OFF HEAT COOL AUTO Heat pumps will also have an EHEAT mode Mode annun ciator displays current selection 3 Press up or down buttons to select desired temperature 4 If daily cycles are to be programmed now refer to Homeown er s Guide for programming instructions 5 If...

Страница 4: ... B L S1 S2 C Y C MODEL AC THERMOSTAT TYPICAL FAN COIL SINGLE SPEED AIR CONDITIONER See notes 3 and 7 W2 Y Y2 W3 Y1 O L E Fig 6 Single Speed Air Conditioner with Typical Fan Coil Dual Stage Heat Control A94274 24 VAC HOT FAN HEAT STAGE 1 COOL STAGE 1 HEAT STAGE 2 N A R G W W1 Y Y2 O W2 Y1 W2 R G 24 VAC COMM N A N A OUTDOOR SENSOR CONNECTION C B L S1 S2 C Y C MODEL HP THERMOSTAT TYPICAL FAN COIL SIN...

Страница 5: ...T TWO STAGE OR VARIABLE SPEED FURNACE TWO SPEED AIR CONDITIONER See note 5 R Y1 R G L W W1 Y Y2 W2 Fig 10 Two Speed Air Conditioner with Typical Fan Coil A94223 24 VAC HOT FAN HEAT STAGE 1 COOL STAGE 2 HEAT STAGE 2 COOL STAGE 1 R G W W1 Y Y2 O W2 Y1 W2 R G 24 VAC COMM N A TROUBLE OUTDOOR SENSOR CONNECTION C B L S1 S2 C Y2 C MODEL 2S THERMOSTAT TYPICAL FAN COIL TWO SPEED AIR CONDITIONER See notes 5...

Страница 6: ...fer to furnace instructions for proper setup 2 On HP models 1 stage cool 2 stage heat O W2 can control second stage heat Refer to indoor unit instructions for proper setup 3 On AC models 1 stage cool 1 stage heat O W2 is not connected Thermostat can only control 1 stage of heat 4 Refer to outdoor unit installation instructions for latent kit requirements 5 O W2 can control second stage heat Refer ...

Страница 7: ...emain for 15 seconds after proper line voltage is restored If the AC line voltage disappears completely the display will immediately go blank Energy Savings Icon This icon is displayed under these conditions 1 speed HP heating without auxiliary heat 2 speed HP on LO or HI speed heating without auxiliary heat 2 speed HP or AC on LO speed cooling Smart Recovery With Smart Recovery selected the trans...

Страница 8: ...6231 49008c Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations Book 1 4 Tab misc misc PC 101 Catalog No 92 33TS TA1C Printed in U S A Form TSTAT 1SI Pg 8 9 94 Replaces New ...

Отзывы: