T-318
3
−
1
SECTION 3
MICROPROCESSOR
3.1 TEMPERATURE CONTROL
MICROPROCESSOR SYSTEM
The temperature control Micro-Link 3 microprocessor
system (see Figure 3-1) consists of a keypad, display
module, control module (controller), and
interconnecting wiring. The controller houses the
temperature control software and the DataCORDER
Software. The temperature control software functions to
operate the unit components as required to provide the
desired cargo temperature and humidity.
The DataCORDER software functions to record unit
operating parameters and cargo temperature
parameters for future retrieval. Coverage of the
temperature control software begins with paragraph
3.2. Coverage of the DataCORDER software is
provided in paragraph 3.8.
The keypad and display module serve to provide user
access and readouts for both of the controller functions,
temperature control, and DataCORDER. The functions
are accessed by keypad selections and viewed on the
display module. The components are designed to
permit ease of installation and removal.
TO
DISPLAY
CONTROL MODULE
DISPLAY MODULE
KEYPAD
CONFIGURATION
SOFTWARE
CONFIGURATION
VARIABLE
(CnF##)
TEMPERATURE CONTROL SOFTWARE
ALARMS
(AL<70)
Pre-trip
INTERROGATION
CONNECTOR
DATAREADER
Computer Device
With DataLINE
Software
DataCORDER SOFTWARE
OPERATIONAL
SOFTWARE
FUNCTION
CODE (Cd)
TO
DISPLAY
CONFIGURATION
SOFTWARE
CONFIGURATION
VARIABLE
(dCF## read only)
ALARMS
(AL>68)
DATA
STORAGE
MEMORY
OPERATIONAL
SOFTWARE
FUNCTION
CODE (dC)
TO
DISPLAY
(Scrollback)
Operation/Config.
PCMCIA CARD
Data Bank
PCMCIA CARD
Figure 3-1 Temperature Control System
Содержание 69NT40-541-300
Страница 2: ......
Страница 4: ......
Страница 20: ......
Страница 32: ......
Страница 128: ......
Страница 131: ...7 3 T 318 Based on Drawing 62 66058 Figure 7 2 SCHEMATIC DIAGRAM Units with 3 Phase Evaporator Motors...
Страница 133: ...7 5 T 318 6 Heater FCCH FCCH Figure 7 4 SCHEMATIC DIAGRAM Units with Normal Evaporator Fan Capability...
Страница 134: ...7 6 T 318 FCCH FCCH Figure 7 5 SCHEMATIC DIAGRAM Units with Single Evaporator Fan Capability...
Страница 136: ...7 8 T 318 To ST10 To TRX2 To QC1 To QC1 To QC1 To MC6 CONTROLLER Figure 7 7 SCHEMATIC DIAGRAM Emergency Bypass...
Страница 138: ...7 10 T 318 Based on Drawing 62 66058 Figure 7 9 UNIT WIRING DIAGRAM Units with 3 Phase Evaporator Motors Sheet 1 of 2...
Страница 139: ...7 11 T 318 Based on Drawing 62 66058 Figure 7 10 UNIT WIRING DIAGRAM Units with 3 Phase Evaporator Motors Sheet 2 of 2...
Страница 144: ......
Страница 150: ......
Страница 151: ......