SECTION 2
DESCRIPTION
2.1 GENERAL DESCRIPTION
2.1.1 Refrigeration Unit
−
Front Section
The unit is designed so that the majority of the
components are accessible from the front (see
Figure 2-1). The unit model number, serial number, and
parts identification number can be found on the serial
plate to the left of the compressor.
2.1.2 Fresh Air Makeup Vent
The function of the upper or lower makeup air vent is to
provide ventilation for commodities that require fresh air
circulation. A manually operated venting system is
located in the upper left access panel.
The optional eAutoFresh vent system is to moderate the
atmospheric level in the container in response to cargo
respiration. When transporting frozen cargo loads the
vent will be closed. The upper left access panel contains
the vent slide and motor assembly. It may be removed to
allow entry into the evaporator section where the CO
2
sensor and drive pack are located.
1. Access Panel (Evap Fan #1) / TXV / HTT)
2. Fork Lift Pockets
3. Control Box
4. Compressor
5. Unit Serial Number, Model Number, and
Parts Identification Number (PID) Plate
6. Condenser Fan
7. TransFRESH Communications Connector
8. Interrogator Connector (Front Left)
9.
Temperature Recorder
10. Lower Fresh Air Makeup Vent Location
(Blank Cover Shown)
11. TIR (Transports Internationaux Routiers)
Sealing Provisions - Typical All Panels
12. Upper Fresh Air Makeup Vent or eAutoFresh
(Automatic Vent) panel
13. Access Panel (Evaporator Fan #2)/ Humidity
Sensor / Return Temperature Sensor
Figure 2-1 Refrigeration Unit
−
Front Section
Содержание 69NT40-541-300
Страница 2: ......
Страница 4: ......
Страница 20: ......
Страница 32: ......
Страница 128: ......
Страница 131: ...7 3 T 318 Based on Drawing 62 66058 Figure 7 2 SCHEMATIC DIAGRAM Units with 3 Phase Evaporator Motors...
Страница 133: ...7 5 T 318 6 Heater FCCH FCCH Figure 7 4 SCHEMATIC DIAGRAM Units with Normal Evaporator Fan Capability...
Страница 134: ...7 6 T 318 FCCH FCCH Figure 7 5 SCHEMATIC DIAGRAM Units with Single Evaporator Fan Capability...
Страница 136: ...7 8 T 318 To ST10 To TRX2 To QC1 To QC1 To QC1 To MC6 CONTROLLER Figure 7 7 SCHEMATIC DIAGRAM Emergency Bypass...
Страница 138: ...7 10 T 318 Based on Drawing 62 66058 Figure 7 9 UNIT WIRING DIAGRAM Units with 3 Phase Evaporator Motors Sheet 1 of 2...
Страница 139: ...7 11 T 318 Based on Drawing 62 66058 Figure 7 10 UNIT WIRING DIAGRAM Units with 3 Phase Evaporator Motors Sheet 2 of 2...
Страница 144: ......
Страница 150: ......
Страница 151: ......