![Carrier 59CU5A Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/carrier/59cu5a/59cu5a_installation-start-up-operating-and-service-and-maintenance-instructions_2562894006.webp)
59CU5A: Installation, Start-up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
6
load estimates and select the furnace. Excessive oversizing of the
furnace may cause the furnace and/or vent to fail prematurely, customer
discomfort and/or vent freezing.
Failure to follow these guidelines is considered faulty installation and/or
misapplication of the furnace; and resulting failure, damage, or repairs
may impact warranty coverage.
For accessory installation details, refer to the applicable instruction
literature.
NOTE:
Remove all shipping materials, loose parts bags, and literature
before operating the furnace, see
. The Ultra Low NOx
condensing furnaces also contain an additional parts bag for the
condensate trap, see Condensate Trap section.
A190256
Fig. 4 – Prohibited Installations
Downflow not permitted with any return air configuration.
A93044
Fig. 5 – Installation in a Garage
Table 2 – Loose Parts Bag
CODES AND STANDARDS
Follow all national and local codes and standards in addition to these
instructions. The installation must comply with regulations of the
serving gas supplier, local building, heating, plumbing, and other codes.
In absence of local codes, the installation must comply with the national
codes listed below and all authorities having jurisdiction.
In the United States, follow all codes and standards for the following:
Safety
• Current edition of US: National Fuel Gas Code (NFGC) NFPA
54/ANSI Z223.1 and the Installation Standards, Warm Air Heating
and Air Conditioning Systems ANSI/NFPA 90B
General Installation
• US: NFGC and the NFPA 90B. For copies, contact the National Fire
Protection Association Inc., Batterymarch Park, Quincy, MA 02269;
or for only the NFGC contact the American Gas Association, 400 N.
Capitol, N.W., Washington DC 20001
Combustion and Ventilation Air
• US: Current edition of Section 9.3 of the NFPA54/ANSI Z223.1 Air
for Combustion and Ventilation
Duct Systems
• US: Current edition of Air Conditioning Contractors Association
(ACCA) Manual D, Sheet Metal and Air Conditioning Contractors
National Association (SMACNA), or American Society of Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE)
Fundamentals Handbook Chapter 35
Acoustical Lining and Fibrous Glass Duct
• US: Current edition of SMACNA, NFPA 90B as tested by UL
Standard 181 for Class I Rigid Air Ducts
Gas Piping and Gas Pipe Pressure Testing
• US: Current edition of NFPA 54/ANSI Z223.1 NFGC; Chapters 5, 6,
7, and 8 and national plumbing codes.
In the state of Massachusetts:
• This product must be installed by a licensed plumber or gas fitter.
• When flexible connectors are used, the maximum length shall not
exceed 36 in. (914 mm).
• When lever type gas shutoffs are used they shall be T-handle type.
• The use of copper tubing for gas piping is not approved by the state of
Massachusetts.
Electrical Connections
• US: Current edition of National Electrical Code (NEC) NFPA 70
Condensate Drain Connection
• US: Current edition of National Standard Plumbing Code, Section 8.7.
WARNING
!
FIRE HAZARD
Failure to follow this warning could result in personal injury, death
and/or property damage.
Do not install the furnace on its back or hang furnace with control
compartment facing downward. Safety control operation will be
adversely affected. Never connect return-air ducts to the back of the
furnace, see
.
BACK POSITIONED
DOWNWARD
AIR RETURN
CUT IN BACK
BACK POSITIONED
UPWARD
18-IN. (457.2 mm)
MINIMUM TO BURNERS
DESCRIPTION
QTY
Air Intake Pipe Flange
1
Vent Pipe Flange
1
Pipe Flange Gaskets
2
Sharp Tip Screws (Vent and Inlet Flanges)
10
Vent Pipe Coupling
1
Vent Pipe Coupling Clamps
2
Gas Line Grommet
1
Junction Box Cover
1
Junction Box Base
1
Green Ground Screw
1
Blunt Tip Screws (Junction Box)
3
Thermostat Wire Grommet
1
Rubber Drain Elbow
1
Drain Tube Clamps
2
1/2-in. CPVC to 3/4-in. PVC Pipe Adapter
1