Table 9—Model 58UXT Orifice Size and Manifold Pressure for Correct Input—Continued
(Tabulated Data Based on 20,000 Btuh High Heat/13,000 Btuh Low Heat per Burner
Derated 4 Percent for Each 1000 Ft Above Sea Level)*
ALTITUDE
RANGE
(FT)
AVG GAS
HEAT VALUE
(BTU/CU FT)
SPECIFIC GRAVITY OF NATURAL GAS
0.58
0.60
0.62
0.64
0.66
Orifice
No.
Manifold
Pressure
High/Low
Orifice
No.
Manifold
Pressure
High/Low
Orifice
No.
Manifold
Pressure
High/Low
Orifice
No.
Manifold
Pressure
High/Low
Orifice
No.
Manifold
Pressure
High/Low
U.S.A.
Only
4001
to
5000
725
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
44
3.8/1.6
42
3.4/1.4
750
44
3.2/1.3
44
3.3/1.4
44
3.4/1.4
44
3.5/1.5
42
3.6/1.5
775
45
3.6/1.5
45
3.7/1.6
44
3.2/1.3
44
3.3/1.4
43
3.4/1.4
800
45
3.4/1.4
45
3.5/1.5
45
3.6/1.5
45
3.7/1.6
43
3.2/1.3
825
45
3.2/1.3
45
3.3/1.4
45
3.4/1.4
45
3.5/1.5
44
3.6/1.5
850
47
3.6/1.5
47
3.7/1.6
45
3.2/1.4
45
3.3/1.4
44
3.4/1.4
875
47
3.8/1.6
47
3.5/1.5
47
3.6/1.5
47
3.7/1.6
44
3.2/1.4
900
48
3.6/1.5
48
3.8/1.6
47
3.4/1.4
47
3.5/1.5
45
3.6/1.5
925
48
3.4/1.5
48
3.6/1.5
48
3.7/1.6
48
3.8/1.6
45
3.4/1.5
950
48
3.8/1.6
48
3.4/1.4
48
3.5/1.5
48
3.6/1.5
45
3.7/1.6
ALTITUDE
RANGE
(FT)
AVG GAS
HEAT VALUE
(BTU/CU FT)
SPECIFIC GRAVITY OF NATURAL GAS
0.58
0.60
0.62
0.64
0.66
Orifice
No.
Manifold
Pressure
High/Low
Orifice
No.
Manifold
Pressure
High/Low
Orifice
No.
Manifold
Pressure
High/Low
Orifice
No.
Manifold
Pressure
High/Low
Orifice
No.
Manifold
Pressure
High/Low
U.S.A.
Only
5001
to
6000
700
44
3.2/1.3
44
3.3/1.4
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
725
45
3.6/1.5
45
3.7/1.6
45
3.8/1.6
44
3.3/1.4
44
3.4/1.4
750
45
3.4/1.4
45
3.5/1.5
45
3.6/1.5
45
3.7/1.6
45
3.8/1.6
775
45
3.2/1.3
45
3.3/1.4
45
3.4/1.4
45
3.5/1.5
45
3.6/1.5
800
47
3.5/1.5
47
3.6/1.5
45
3.2/1.3
45
3.3/1.4
45
3.4/1.4
825
48
3.8/1.6
47
3.4/1.4
47
3.5/1.5
47
3.7/1.5
45
3.2/1.3
850
48
3.6/1.5
48
3.7/1.6
48
3.8/1.6
47
3.4/1.5
47
3.5/1.5
875
48
3.4/1.4
48
3.5/1.5
48
3.6/1.5
48
3.7/1.6
48
3.8/1.6
900
49
3.7/1.6
49
3.8/1.6
48
3.4/1.4
48
3.5/1.5
48
3.6/1.5
925
49
3.5/1.5
49
3.6/1.5
49
3.8/1.6
48
3.3/1.4
48
3.4/1.4
950
49
3.3/1.4
49
3.5/1.5
49
3.6/1.5
49
3.7/1.6
49
3.8/1.6
975
50
3.7/1.6
49
3.3/1.4
49
3.4/1.4
49
3.5/1.5
49
3.6/1.5
1000
50
3.6/1.5
50
3.7/1.6
50
3.8/1.6
49
3.3/1.4
49
3.4/1.4
ALTITUDE
RANGE
(FT)
AVG GAS
HEAT VALUE
(BTU/CU FT)
SPECIFIC GRAVITY OF NATURAL GAS
0.58
0.60
0.62
0.64
0.66
Orifice
No.
Manifold
Pressure
High/Low
Orifice
No.
Manifold
Pressure
High/Low
Orifice
No.
Manifold
Pressure
High/Low
Orifice
No.
Manifold
Pressure
High/Low
Orifice
No.
Manifold
Pressure
High/Low
U.S.A.
Only
6001
to
7000
650
44
3.2/1.4
44
3.3/1.4
44
3.4/1.4
44
3.5/1.5
44
3.6/1.5
675
45
3.6/1.5
45
3.7/1.6
45
3.8/1.6
44
3.3/1.4
44
3.4/1.4
700
45
3.3/1.4
45
3.5/1.5
45
3.6/1.5
45
3.7/1.6
45
3.8/1.6
725
47
3.7/1.6
45
3.2/1.4
45
3.3/1.4
45
3.4/1.5
45
3.5/1.5
750
47
3.5/1.5
47
3.6/1.5
47
3.7/1.6
45
3.2/1.4
45
3.3/1.4
775
48
3.7/1.6
48
3.8/1.6
47
3.5/1.5
47
3.6/1.5
47
3.7/1.6
800
48
3.5/1.5
48
3.6/1.5
48
3.7/1.6
48
3.8/1.6
47
3.5/1.5
825
49
3.8/1.6
48
3.4/1.4
48
3.5/1.5
48
3.6/1.5
48
3.7/1.6
850
49
3.6/1.5
49
3.7/1.6
48
3.3/1.4
48
3.4/1.4
48
3.5/1.5
875
49
3.4/1.4
49
3.5/1.5
49
3.6/1.5
49
3.8/1.6
48
3.3/1.4
* Orifice numbers 45 are factory installed
19