Unit Size: 070V21--20
Clg/CF Switch settings
External Static Pressure (ESP)
Clg Switches:
SW2-8
SW2-7
SW2-6
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Clg Default:
OFF
OFF
OFF
1930
1895
1855
1815
1775
1740
1700
1665
1630
1595
Cooling
(SW2-8,7,6)
OFF
OFF
ON
810
735
660
585
505
See Note 4
OFF
ON
OFF
1010
945
885
820
760
695
625
565
510
455
OFF
ON
ON
1205
1150
1090
1040
985
930
875
820
760
705
ON
OFF
OFF
1400
1345
1295
1245
1200
1155
1105
1060
1005
960
ON
OFF
ON
1580
1540
1495
1445
1405
1360
1320
1275
1235
1190
ON
ON
OFF
1930
1895
1855
1815
1775
1740
1700
1665
1630
1595
ON
ON
ON
2245
2195
2145
2095
2045
1995
1935
1885
1835
1785
Maximum Clg Airflow
2
2245
2195
2145
2095
2045
1995
1935
1885
1835
1785
CF Switches
SW2-5
SW2-4
SW2-3
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Low-Clg Default:
OFF
OFF
OFF
810
735
660
585
505
See Note 4
Low-Cooling
(SW2-5,4,3)
OFF
OFF
ON
585
490
See Note 4
OFF
ON
OFF
810
735
660
585
505
See Note 4
OFF
ON
ON
1010
945
885
820
760
695
625
565
510
455
ON
OFF
OFF
1205
1150
1090
1040
985
930
875
820
760
705
ON
OFF
ON
1400
1345
1295
1245
1200
1155
1105
1060
1005
960
ON
ON
OFF
1580
1540
1495
1445
1405
1360
1320
1275
1235
1190
ON
ON
ON
1930
1895
1855
1815
1775
1740
1700
1665
1630
1595
Cont. Fan Default:
OFF
OFF
OFF
810
735
660
585
505
See Note 4
Continuous Fan
(SW2-5,4,3)
OFF
OFF
ON
585
490
See Note 4
OFF
ON
OFF
810
735
660
585
505
See Note 4
OFF
ON
ON
1010
945
885
820
760
695
625
565
510
455
ON
OFF
OFF
1205
1150
1090
1040
985
930
875
820
760
705
ON
OFF
ON
1400
1345
1295
1245
1200
1155
1105
1060
1005
960
ON
ON
OFF
1400
1345
1295
1245
1200
1155
1105
1060
1005
960
ON
ON
ON
1400
1345
1295
1245
1200
1155
1105
1060
1005
960
Heating (SW1)
Heat Airflow
3
1435
1385
1335
1290
1245
1195
1145
1100
1050
1000
Unit Size: 090V21--20
Clg/CF Switch settings
External Static Pressure (ESP)
Clg Switches:
SW2-8
SW2-7
SW2-6
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Clg Default:
OFF
OFF
OFF
1985
1935
1885
1835
1785
1735
1685
1630
1583
1532
Cooling
(SW2-8,7,6)
OFF
OFF
ON
860
755
650
545
445
See Note 4
OFF
ON
OFF
1085
1000
910
830
735
655
565
485
405
310
OFF
ON
ON
1255
1180
1105
1025
950
870
790
715
640
570
ON
OFF
OFF
1425
1355
1290
1220
1150
1085
1015
940
870
800
ON
OFF
ON
1630
1575
1515
1455
1395
1330
1270
1210
1155
1090
ON
ON
OFF
1985
1935
1885
1835
1785
1735
1685
1630
1583
1532
ON
ON
ON
2100
2055
2010
1960
1915
1870
1820
1775
1715
1640
Maximum Clg Airflow
2
2100
2055
2010
1960
1915
1870
1820
1775
1715
1640
CF Switches
SW2-5
SW2-4
SW2-3
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Low-Cooling
(SW2-5,4,3)
OFF
OFF
ON
700
575
See Note 4
OFF
ON
OFF
860
755
650
545
445
See Note 4
OFF
ON
ON
1085
1000
910
830
735
655
565
485
405
310
ON
OFF
OFF
1255
1180
1105
1025
950
870
790
715
640
570
ON
OFF
ON
1425
1355
1290
1220
1150
1085
1015
940
870
800
ON
ON
OFF
1630
1575
1515
1455
1395
1330
1270
1210
1155
1090
ON
ON
ON
1985
1935
1885
1835
1785
1735
1685
1630
1583
1532
Cont. Fan Default:
OFF
OFF
OFF
860
755
650
545
445
See Note 4
Continuous Fan
(SW2-5,4,3)
OFF
OFF
ON
700
575
See Note 4
OFF
ON
OFF
860
755
650
545
445
See Note 4
OFF
ON
ON
1085
1000
910
830
735
655
565
485
405
310
ON
OFF
OFF
1255
1180
1105
1025
950
870
790
715
640
570
ON
OFF
ON
1425
1355
1290
1220
1150
1085
1015
940
870
800
ON
ON
OFF
1630
1575
1515
1455
1395
1330
1270
1210
1155
1090
ON
ON
ON
1630
1575
1515
1455
1395
1330
1270
1210
1155
1090
Heating (SW1)
Heat Airflow
3
1830
1775
1725
1675
1625
1570
1520
1465
1410
1360
Table 13 – Air Delivery - CFM (With Filter)* (Continued)
COOLING
4
AND HEATING AIR DELIVERY - CFM (Bottom Return
5
with Filter)
(SW1-5 and SW2-2 set to OFF, except as indicated. See Notes 1 and 2.)