b. Jumper R, W/W1 and W2 thermostat connections on
control to run furnace in high heat. (See Fig. 32 and 51.)
c. Turn high-heat adjusting screw (5/64 hex Allen wrench)
counterclockwise (out) to decrease input rate or clockwise
(in) to increase rate.
d. Re-install high-heat adjustment caps.
NOTE:
DO NOT set high-heat manifold pressure less than 3.2-in.
wc or more than 3.8-in. wc for natural gas. If manifold pressure is
outside this range, change main burner orifices.
7. Verify natural gas high fire input rate by clocking meter.
NOTE:
Gas valve regulator adjustment caps must be in place for
proper input to be clocked.
a. Turn off all other gas appliances and pilots.
b. Run for 3 minutes in high-heat operation.
c. Measure time (in sec) for gas meter to complete 1 revolu-
tion and note reading.
d. Refer to Table 9 for cubic ft of gas per hr.
e. Multiply gas rate cu ft/hr by heating value (Btu/cu ft) to
obtain input.
NOTE:
Using the 2 cu. ft. or 5 cu. ft. gas meter dial provides
greater accuracy in verifying gas input rate.
If clocked rate does not match required input from Step 1, increase
manifold pressure to increase input or decrease manifold pressure
to decrease input. Repeat steps b through e until correct high fire
input is achieved. Re-install high-fire regulator seal cap on gas
valve.
8. Set high heat temperature rise.
Jumper R to W/W1 and W2 to check high-gas-heat tempera-
ture rise. Do not exceed temperature rise ranges specified on
unit rating plate for high fire.
NOTE:
Blower access door must be installed when taking tem-
perature rise reading. Leaving blower access door off will result in
incorrect temperature measurements.
a. Verify the unit is operating in high fire per Step 6. Place
thermometers in return and supply ducts as close to furnace
as possible. Be sure thermometers do not see radiant heat
from heat exchangers. Radiant heat affects temperature rise
readings. This practice is particularly important with
straight-run ducts.
b. When thermometer readings stabilize, subtract return-air
temperature from supply-air temperature to determine air
temperature rise.
Recheck temperature rise. It must be within limits specified
on the rating plate. Operation is within a few degrees of the
mid-point of rise range when setup switch SW1-4 is OFF.
When setup switch SW1-4 is ON, operation will be near the high
end of the rise range for improved comfort.
This furnace is capable of automatically providing proper airflow
to maintain the temperature rise within the range specified on unit
rating plate.
NOTE:
If the temperature rise is outside this range, first check:
1.) Gas input for low-and high-fire opeation.
2.) Derate for altitude if applicable.
3.) Return and supply ducts for excessive restrictions causing static
pressures greater than 0.50-in. wc.
4.) Make sure proper model plug is installed.
c. Remove thermostat jumpers and release blower access door
switch.
d. Repeat Steps a through c as required to adjust for proper
rise.
e. When correct high heat input rate and temperature rise is
achieved, turn gas valve ON/OFF switch to OFF.
f. Release blower access door switch.
g. Remove manometer or similar device from gas valve.
h. Re-install manifold pressure tap plug in gas valve. (See
Fig. 47.)
Failure to reinstall manifold pressure tap plug in gas valve
will result in fore, explosion, personal injury, property dam-
age or death.
i. Remove thermostat jumper wire from furnace control
board.
j. Turn gas valve ON/OFF switch to ON.
Table 9–GAS RATE (CU FT/HR)
SECONDS
FOR 1
REVOLUTION
SIZE OF TEST DIAL
SECONDS
FOR 1
REVOLUTION
SIZE OF TEST DIAL
1
Cu Ft
2
Cu Ft
5
Cu Ft
1
Cu Ft
2
Cu Ft
5
Cu Ft
10
360
720
1800
50
72
144
360
11
327
655
1636
51
71
141
355
12
300
600
1500
52
69
138
346
13
277
555
1385
53
68
136
340
14
257
514
1286
54
67
133
333
15
240
480
1200
55
65
131
327
16
225
450
1125
56
64
129
321
17
212
424
1059
57
63
126
316
18
200
400
1000
58
62
124
310
19
189
379
947
59
61
122
305
20
180
360
900
60
60
120
300
21
171
343
857
62
58
116
290
22
164
327
818
64
56
112
281
23
157
313
783
66
54
109
273
24
150
300
750
68
53
106
265
25
144
288
720
70
51
103
257
26
138
277
692
72
50
100
250
27
133
267
667
74
48
97
243
28
129
257
643
76
47
95
237
29
124
248
621
78
46
92
231
30
120
240
600
80
45
90
225
31
116
232
581
82
44
88
220
32
113
225
563
84
43
86
214
33
109
218
545
86
42
84
209
34
106
212
529
88
41
82
205
35
103
206
514
90
40
80
200
36
100
200
500
92
39
78
196
37
97
195
486
94
38
76
192
38
95
189
474
96
38
75
188
39
92
185
462
98
37
74
184
40
90
180
450
100
36
72
180
41
88
176
439
102
35
71
178
42
86
172
429
104
35
69
173
43
84
167
419
106
34
68
170
44
82
164
409
108
33
67
167
45
80
160
400
110
33
65
164
46
78
157
391
112
32
64
161
47
76
153
383
116
31
62
155
48
75
150
375
120
30
60
150
49
73
147
367