Carrier 50JB034 Скачать руководство пользователя страница 7

50JB054,064

(EXTENDED

CHASSIS)

UNIT
SIZE

WEIGHT

A

B

C

D

E

F

lb

kg

mm

ft-in.

mm

ft-in.

mm

ft-in.

mm

ft-in.

mm

ft-in.

mm

ft-in.

50JB054 8800 3990 2959 9-8

1

2

6940 22-9

3

4

6393 20-11

11

16

1163 3-9

25

32

11 780 38-7

13

16

12 164

39-10

7

8

50JB064 9100 4127 2959 9-8

1

2

6940 22-9

3

4

6393 20-11

11

16

1163 3-9

25

32

11 780 38-7

13

16

12 164 39-10

7

8

NOTES:
1.

Dimensions in [

] are in millimeters.

2.

Center of Gravity includes economizer. Unit weight does not include economizer or
heating coil.

3. Unit clearances:

Top — Do not restrict condenser fans
Control Box End — 6

8

-0

9

Sides — 6

8

-0

9

Economizer End — 6

8

-0

9

For smaller service and operating clearances, contact Carrier Application Engineering
Department.

4. Suggested field connections to be made inside or outside of 1.28 in. (32.5 mm) flange.
5. When the unit is slab mounted, plug the factory drilled auxiliary condensate drain holes.
6. Auxiliary heating coil is field supplied and installed.
7. Auxiliary heating coil dimensions (maximum):

Length (header included), 7

8

-0

1

4

9

[2140]

Width, 0

8

-9

5

8

9

[244]

Height, 4

8

-5

15

16

9

[1370]

8. Economizer side hoods are folded inside unit for

shipping.

CERTIFIED DIMENSION PRINT

7

CUT ALONG DOTTED LINE

CUT ALONG DOTTED LINE

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

Содержание 50JB034

Страница 1: ...T VOLUME VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS 50JB 1SB R...

Страница 2: ...ish Text Control of a two speed supply fan motor on CV applications Two speed motor available on Special Order Building Purge Mode flushes building interior with outdoor air to remove contaminants bef...

Страница 3: ...er Air Temp F Gross Sensible Capacity Btuh Compressor Power Input kW Indoor Fan Motor Size Hp Return Fan Motor Size Hp Cfm External Static Pressure in wg Curb Weight lb HEATING NO UNIT MOUNTED HEAT AV...

Страница 4: ...LD CONTROL WIRING TYPICAL SPACE TEMPERATURE SENSOR WIRING LEGEND CCN Carrier Comfort Network COM Communications GND Ground SW Switch T Terminal TB Terminal Block TH Thermostat Heating Constant Volume...

Страница 5: ...its 108 09 For smaller service and operating clearances contact Carrier Application Engineering Department 4 Suggested field connections to be made inside or outside of 2 28 in 32 5 mm flange 5 When t...

Страница 6: ...xcept power exhaust units 108 09 For smaller service and operating clearances contact Carrier Application Engineering Department 4 Suggested field connections to be made inside or outside of 1 28 in 3...

Страница 7: ...ances Top Do not restrict condenser fans Control Box End 68 09 Sides 68 09 Economizer End 68 09 For smaller service and operating clearances contact Carrier Application Engineering Department 4 Sugges...

Страница 8: ...ROOF CURB 50JB034 038 EXTENDED CHASSIS CERTIFIED ROOF CURB DIMENSION PRINT 8...

Страница 9: ...ROOF CURB 50JB044 048 EXTENDED CHASSIS CERTIFIED ROOF CURB DIMENSION PRINT 9 CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE...

Страница 10: ...ROOF CURB 50JB054 064 EXTENDED CHASSIS CERTIFIED ROOF CURB DIMENSION PRINT 10...

Страница 11: ...ACCESSORY ROOF CURB 50JB054 064 CERTIFIED ACCESSORY ROOF CURB DIMENSION PRINT 11 CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE...

Отзывы: