Carrier 42VQV Скачать руководство пользователя страница 7

42VQV

GB - 6

Unit warning lights and controls

: Green LED

: Red LED

: Yellow LED

: Remote control

signal receiver

: “Emergency” and

“reset” button

S

P

Q R

T

For a good operation of the
air conditioner it is
recommended to carry out
checks and maintenance
as indicated.
Recommended
maintenance intervals may
vary depending on the
installation environment,
e.g. dusty zones, etc.

(1) Increase frequency in

dusty zones.

(2) Operations to be

carried out by qualified
service personnel.
Refer also to
“Installation Manual”.

Table II: Periodical checks

Indoor unit

Every month

Every 4 months

Every year

Clean air filter (2)

(1)

Clean drain pipe (2)

Change controller batteries

Outdoor unit

Every month

Every 4 months

Every year

Clean outdoor coil from outside (2)

Clean outdoor coil from inside (2)

Blow air over electric parts (2)

Check electric connection tightening (2)

Clean fan wheel (2)

Check fan tightening (2)

Clean drain pan (2)

Indoor unit LEDs

Information concerning indoor unit operation, timer status and
diagnostic is given by 3 LEDs located on the unit.

• The GREEN LED (P) indicates the following conditions:

-  The LED remains ON during the normal operation.

• THE RED LED (Q) gives the following information:

- During normal operation, the LED is OFF;
- During defrost the LED is lit;

• THE YELLOW LED (R) shows the operation in timer mode.

During this operation in this operating mode, the LED is lit.

If the timer mode is active and the unit is immediately restarted
after a stop, this LED flashes until a new signal is sent to the
unit.

The GREEN LED (P) and the YELLOW LED (R) indicate the
following conditions:
  - Error codes (troubleshooting).
When an error code is detected, the LEDs blink one after the other
(First the  GREEN LED (P) that flashes for several times, then the
YELLOW LED (R) for as many times as the other). To identify the
detected error refer to the error code table in the installation manual.

Button T: “EMERGENCY”

Can be used when the remote control is lost or inoperative.
Use a screwdriver to press the push-button.

Emergency operation:

When the unit is in the OFF mode and the T button is pressed for
5 seconds, the unit will operate as follows:

- Automatic mode

- Temperature preset to 22

°

C

- Automatic fan speed

- Louvres set automatically according to the operating mode

- OFF timer

When a signal is received by the remote control, the unit operates
accordingly.

Содержание 42VQV

Страница 1: ...42VQV Console Underceiling T h e S t andards Institutiono f I s r a e l Q u ality Assured Fi r m SI ISO 9001 OWNER S MANUAL...

Страница 2: ...ed in the relevant manuals The installation instructions for both the indoor and the outdoor unit are given in the manuals for each unit Contents Page General information 2 System description 3 Infrar...

Страница 3: ...y qualified personnel Do not open the electronic remote controller to avoid possible damage In case of malfunction contact a qualified service engineer This unit contains rotating equipment fan Ensure...

Страница 4: ...oor unit B Indoor unit 1 Remote control signal receiver 2 Unit operating status LEDs 3 Louvre 4 Air return 5 Air filters 6 Air outlet 7 Characteristics nameplate 8 Interconnecting tubing 9 Condensate...

Страница 5: ...eceiver may interfere with good signal reception The control must be directed toward the unit receiver when pressing the buttons of the desired functions An acoustical acknowledgement sound beep will...

Страница 6: ...and current time 15 OFF timer selected Table I Unit protection devices WARNING During heat pump operation the unit will undergo several defrost cycles to remove ice that might collect on the outdoor u...

Страница 7: ...he following conditions The LED remains ON during the normal operation THE RED LED Q gives the following information During normal operation the LED is OFF During defrost the LED is lit THE YELLOW LED...

Страница 8: ...g The unit will only emit a beep when the signals are received correctly Selection of the operating mode button A With this button the operating mode of the air conditioner can be selected By repeated...

Страница 9: ...n will stop flashing 7 Louvre positioning Now this icon is flashing Use button to select desired position Press button for confirmation Now all icons are fixed on display If you want to cancel selecti...

Страница 10: ...Press the Everyday button daily button Cancellation of ON OFF and DAILY timer procedure 1 If you want to cancel On or OFF timer setting press the following buttons in sequence button or button To deac...

Страница 11: ...it in operation for half a day in the ventilation fan only mode in order to dry all its internal parts Switch electric mains supply off Take batteries out of the controller Clean indoor and outdoor un...

Страница 12: ...operating modes of the air conditioner such as Turning the unit on and off Changing the operation modes Temperature selection Directional louvre control for optimizing the air flow direction Leave the...

Страница 13: ...by severe interference from an electromagnetic field avoid sending signals when computers or household appliances food processors coffee grinders etc are operating close by Cellular or cordless teleph...

Страница 14: ...H18 0604 Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice June 2004 Supersedes September 2003 Printed in...

Отзывы: