NAMES OF PARTS
OPERATING INSTRUCTIONS
8. Connecting pipe
9. Connecting cable
10. Stop valve
Outdoor unit
Indication lamp
NOTE:
All the pictures in this manual are for
explanation purposes only. The actual shape
of the indoor unit you purchased may be slight
different on front panel and display window.The
actual shape shall prevail.
Air inlet(
rear)
Air inlet
(side)
Air outlet
1. Front panel
2. Air inlet
3. Air filter
4. Air outlet
5. Horizontal air flow grille
6. Vertical air flow louver(inside)
7. Display panel
Indoor unit
OPERATION indication lamp
This lamp illuminates when the air
conditioner is in operation.
TIMER indication lamp
Lights up during Timer operation.
DEFROST indication lamp
(Enabled on cooling & heating models only):
Lights up when the air conditioner starts
defrosting automatically or when the warm
air control feature is activated in heating
operation.
Special functions
Names of parts
Improving the quality of indoor air is one of the purposes of an air conditioner. This
air
conditioner is equipped with ionizer or Plasma Dust Collector(Depending on specific
configuration of the model). With the anions generated by Ionizer, the air circulation
of the air conditioner fills the room with refreshing, natural and healthy air. The Plasma
Dust Collector generates a high voltage ionization zone, through which the air is
converted to plasma. Inside the air most of the dust, smoke, and pollen particles are
captured by the electrostatic filter.
CLEAN AIR function(on some models)
Function used after the shut down of cooling operation to clean the Evaporator
,it keeps the air fresh for the next operation.
For cooling models, the unit will operate under FAN ONLY mode
at LOW fan speed for half an hour, and then turn off automatically.
For cooling & heating models, the unit will operate as in the below sequence :
FAN ONLY mode at Low fan speed--Heating operation with LOW fan speed
---FAN ONLY operation--Stop Operation---Turn off.
Note:
This function is only available under COOL(AUTO COOL, FORCED COOL) and
DRY mode.
Before selecting the function, it is recommended to run the air conditioner under
cooling operation for about half an hour. Once the Self Clean function is activated,
all TIMER setting will be cancelled.
During SELF CLEAN operation, when pressing the SELF CLEAN button on the remote
controller again,the unit will stop the operation and turn off the unit automatically.
SELF CLEAN function Optional
4
3
5
2
6
1
9
10
8
7
Signal receiver
A
B
Signal receiver
Refrigerant Leakage Detection
With this new technology, the dipsplay area will appear EC and the indication lamps
continue flashing when the outdoor unit detects refrigerant leakage.
Temperature indicator
Displays the temperature settings when the
air conditioner is operational.
Displays the malfunction code.
Anti-mildew function
Optional
When turns off the unit on COOL, DRY, AUTO (Cool) mode, the air conditioner will continue
operating for about 10 minutes (depending on models) with soft wind.This will help to
dry up the condensed water inside the evaporator, and prevent the breeding of mildew.
Under Anti-mildew operation, do not restart the air conditioner until the unit iscompletely off.
,
,
Louver Angle Memory Function(optional):
Within the scope of safety angle, it will memorize the open angle of horizontal louver.
If it exceeds, it will memorize the boundry of safety angle. In the following circumstances,
it will return to standard angle: 1) pressing the turbo or manual control button, 2)unplug
and then plug in the machine. So we strongly suggest that the open angle of the horizontal
louver should not be set too small, in case the condensed water forms and drops from the
horizontal louver.