background image

GB - 4

42PQV

Ensure that the air distribution in the room is uniform by properly
adjusting the air flow direction.

Correct cleaning

• Turn the unit off and switch the mains supply off.

Use only a clean, damp and soapy cloth.
Do not pour any liquids on the unit.
Do not use flammable liquids, solvents or abrasive powders.

Keep heat sources away from the unit and do not place anything
hot on it; panels may be damaged.
The remote control should only be cleaned with a dry cloth.

Occasionally clean the area around the outdoor (leaves etc.) to
avoid reduced air circulation.

Air cleaning system

a

Standard air filters:

 they eliminate dust and lint.

b

Electrostatic photocatalytic filter:

 this effectively

eliminates microscopic dust and cigarette smoke in the room air.

Optimum comfort and lowest consumption

Keep room temperature at comfort levels.
Do not open doors and windows more frequently than necessary.

When cooling, avoid direct sun in the room: if possible, shut
curtains or shades.

Do not obstruct the air intake or outlet of the unit.
Obstructions will cause a reduction of the air quantity and the
conditioning effect, resulting in unit malfunction.

Air cleaning system, optimum comfort and lowest consumption, correct cleaning

a

     a

b

c

Содержание 42PQV

Страница 1: ...42PQV OWNER S MANUAL L L O Y D S R E G I S TER QUALIT Y A S S U R A N C E IS O 900 1...

Страница 2: ...re contained in the relevant manuals The installation instructions for both the indoor and the outdoor unit are given in the manuals for each unit Contents Page General information 2 System descriptio...

Страница 3: ...e control to avoid possible damage In case of malfunction contact a qualified service engineer This unit contains moving parts Ensure that these parts are kept out of the reach of children Maintain th...

Страница 4: ...fied service personnel Refer also to Installation Manual Table I Periodical checks Indoor unit Every month Every 4 months Every year Clean air filter 1 Clean drain pipe Change controller batteries Out...

Страница 5: ...leaves etc to avoid reduced air circulation Air cleaning system a Standard air filters they eliminate dust and lint b Electrostatic filter photocatalytic filter this effectively eliminates microscopi...

Страница 6: ...rnal parts Switch the electric mains supply off Take the batteries out of the controller Clean indoor and outdoor units Filter cleaning Clean filters in accordance with the actual operating conditions...

Страница 7: ...ive 11 ON timer selected 12 Night timer active 13 DAILY timer active Everyday 14 ON timer OFF timer and current time 15 OFF timer selected Table II Unit protection devices WARNING During heat pump ope...

Страница 8: ...unit receiver when pressing the buttons of the desired functions An acoustical acknowledgement sound beep will indicate that signal has been received 1 A B D E G H J K M N C F I L O A AM PM A B 1 2 F...

Страница 9: ...nit will only emit a beep when the signals are received correctly Selection of the operating mode button A With this button the operating mode of the air conditioner can be selected By repeatedly pres...

Страница 10: ...on will stop flashing 7 Louvre positioning Now this icon is flashing Use button to select desired position Press button for confirmation Now all icons are fixed on display If you want to cancel select...

Страница 11: ...oid overcooling or overheating during operation The set temperature will change as follows DAILY timer Everyday button J Push the button when the ON or OFF timer is active The icon will appear on disp...

Страница 12: ...receiver turn the remote control OFF and repeat the operation pointing the remote control in the correct direction There are obstacles curtains partitions etc between the remote control and the unit...

Страница 13: ...42PQV OM Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice May 2003 Printed in Korea...