GB - 12

42PHQ. . . P 

R-410A

Operating features and care - Troubleshooting

Operating conditions

• Temperature ranges suitable for unit operation are as follows.

• If the unit operates beyond max. temperature conditions for a

long time, system diagnostics may detect a malfunction and the
unit will not operate properly.

• If the unit operates for a long time under abnormal conditions

with extremely high humidity, condensed water may drip from the
unit.

Time delay

• If you start operation after the power is turned off, there will be a

3/5 minute time delay until the compressor turns on.

• When heating operation starts, hot air delivery might be delayed

due to a warm-up period.

Minimum operation time

• In normal operation, there is a minimum operation time of 5~7

minutes between the compressor turning on and turning back off.

Heating features
(for heat pump models only)

• If the unit starts in heating mode, there will be a preheating

period before the unit is ready to deliver warm air.

• If the outdoor temperature is low, heating capacity will be

reduced. If the room air is not warm enough during severe winter
conditions, use additional heating devices.

Defrost operation
(for heat pump models only)

• In heating mode, if the outdoor coil is frosted, the indoor fan and

outdoor fan will turn off while the compressor will turn on to
remove the frost on the outdoor coil.

• The system will operate again when frost is removed from the

outdoor unit

Auto recovery

• If the power fails while the unit is operating, the unit memorizes

the operating condition, and it will start operation automatically
when the power is restored or turn off, depending on the
configuration of the remote control.

Indoor unit frost prevention

If the unit operates at a low ambient temperature, frost may
appear on the indoor coil. If the indoor coil temperature is near
0

°

C, the microcomputer stops the compressor to protect the unit

from frost

Normal operation

Any of the following can occur during normal operation:
• A gurgling noise can sometimes be heard during operation or

when the unit stops.

- This is the sound of the refrigerant flowing through the unit.

• Bad odours can come from the unit.

- Odours such as smoke or cosmetics can accumulate while

room air circulates through the unit.

- Cleaning the filters will reduce this problem.

• The outdoor fan does not rotate during heating operation.

(For heat pump models only).
- The unit is in defrost mode.

• A crackling sound can sometimes be heard during operation or

when the unit turns on.

- It is the sound of plastic expanding due to an abrupt

temperature change.

MODE

INDOOR

OUTDOOR

COOL/DRY

21~32

°

C

21~43

°

C

HEAT

Max. 27

°

C

Max. 24

°

C

Troubleshooting

Trouble / Check points / Action /

Unit does not operate:

• Has the circuit breaker tripped or the fuse blown?

RESET

 

THE

 

CIRCUIT

 

BREAKER

 

OR

 

REPLACE

 

THE

 

FUSE

 

WITH

 

THE

 

SPECIFIED

REPLACEMENT

 

FUSE

.

• Has there been a power failure?

RESTART

 

OPERATION

 

WHEN

 

THE

 

POWER

 

IS

 

RESTORED

.

• Does the green light flash on and off?

CALL

 

YOUR

 

SERVICE

 

REPRESENTATIVE

.

• Is the voltage too low?

CONFIRM

 

THE

 

AVAILABLE

 

VOLTAGE

.

Cooling is abnormally low:

• Is the filter blocked with dust?

CLEAN

 

THE

 

AIR

 

FILTER

.

• Has the temperature been set properly?

CHECK

 

AND

 

RESET

 

IT

 

IF

 

NECESSARY

.

• Are the windows or doors open?

CLOSE

 

THE

 

WINDOWS

 

AND

 

DOORS

.

• Is anything obstructing the outdoor unit?

REMOVE

 

THE

 

OBSTRUCTION

.

• Is the fan speed too low?

CHANGE

 

THE

 

FAN

 

SPEED

 

SELECTION

.

• Is the operation mode FAN or AUTO?

CHANGE

 

TO

 

COOLING

 

OPERATION

 

OR

 

RESET

Heating is abnormally low (for heat pump models only):

• Is the filter blocked with dust?

CLEAN

 

THE

 

AIR

 

FILTER

.

• Has the temperature been set too low?

CHECK

 

AND

 

RESET

 

IT

 

IF

 

NECESSARY

.

• Are the windows or doors open?

CLOSE

 

THE

 

WINDOWS

 

AND

 

DOORS

.

• Is anything obstructing the outdoor unit?

REMOVE

 

THE

 

OBSTRUCTION

.

Unit stops during operation:

• Is the OFF timer operating?

RESTART

 

THE

 

OPERATING

 

MODE

.

• Does the green light flash on and off?

CALL

 

YOUR

 

SERVICE

 

REPRESENTATIVE

.

ATTENTION:
If the above actions do not correct the problem, consult the dealer
from whom you bought the unit.

Содержание 42PHQ P Series

Страница 1: ...42PHQ P OWNER S MANUAL L L O Y D S R E G I S TER QUALIT Y A S S U R A N C E IS O 900 1 R 410A...

Страница 2: ...frared remote controller 4 Display of selected functions 5 Unit protection devices 5 Unit display and switch panel 6 Periodical checks 6 Use of the remote controller 7 9 Air cleaning system 10 Optimum...

Страница 3: ...ssible damage In case of malfunction contact a qualified service engineer This unit contains rotating parts fan Ensure that this is out of reach for children Be conscious of the room temperature and g...

Страница 4: ...or unit B Indoor unit System description 1 Automatic swinging louvre 2 Air return 3 Air filters 4 Air outlet 5 Unit operating status indicators 6 Remote control signal receiver 7 Unit nameplate 8 Inte...

Страница 5: ...l reception The control must be directed toward the unit receiver when pressing the buttons of the desired functions An acoustical acknowledgement sound beep will indicate that signal has been receive...

Страница 6: ...n devices WARNING During heat pump operation the unit will undergo several defrost cycles to remove ice that might collect on the outdoor unit in very low ambient temperatures In these cycles the indo...

Страница 7: ...ervals may vary depending on the installation environment e g dusty zones etc 1 Increase frequency in dusty zones 2 Operations to be carried out by qualified service personnel Refer also to Installati...

Страница 8: ...m temperature the unit will not start the same applies for the heating mode if the selected temperature is lower than the room temperature Selecting direction of air flow louvre button H The air flow...

Страница 9: ...ization will be repeated every day To disactivate the daily function press again the button Combination of ON OFF and DAILY timer procedure If you want operation to start at 5 30 P M and stop at 10 30...

Страница 10: ...r Current time adjusting and reset buttons buttons K and O Press current time adjusting button for more than 5 seconds to adjust the current time Press reset button O with a sharp object if the remote...

Страница 11: ...and the conditioning effect resulting in unit malfunction Ensure that the air distribution in the room is uniform by properly adjusting the air flow direction Correct cleaning Turn the unit off and s...

Страница 12: ...nal parts Switch the electric mains supply off Take the batteries out of the controller Clean indoor and outdoor units Filter cleaning Clean filters in accordance with the actual operating conditions...

Страница 13: ...ormal operation Any of the following can occur during normal operation A gurgling noise can sometimes be heard during operation or when the unit stops This is the sound of the refrigerant flowing thro...

Страница 14: ...42KU5A54020 Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice December 2003 Printed in Korea...

Отзывы: