Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Printed in U.S.A.
Form 40RU-7-16-02SI Rev. A
Pg 1
1-22
Replaces: 40RU-7-16-01SI
Installation, Start-up and
Service Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . 1
PRE-INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Moving and Storage . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Rigging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Uncrating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Rated Indoor Airflow (cfm) . . . . . . . . . . . . . . . . . . . . 14
Unit Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Unit Isolation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Refrigerant Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Refrigerant and Chilled Water Piping Access . . . . 15
Chilled Water Piping . . . . . . . . . . . . . . . . . . . . . . . . . 19
Condensate Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Fan Motors and Drives . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Power Supply and Wiring . . . . . . . . . . . . . . . . . . . . . . . 21
Connecting Ductwork . . . . . . . . . . . . . . . . . . . . . . . . 26
• OUTDOOR-AIR INLET CONNECTIONS
Return-Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
40RUA and 40RUQ ONLY . . . . . . . . . . . . . . . . . . . . . 28
Adjusting TXV for Superheat (40RUA and 40RUQ
only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Fan Motor Lubrication . . . . . . . . . . . . . . . . . . . . . . . 28
Fan Shaft Bearings . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Centering Fan Wheel . . . . . . . . . . . . . . . . . . . . . . . . 29
Fan Shaft Position Adjustment . . . . . . . . . . . . . . . . 29
Individual Fan Wheel Adjustment . . . . . . . . . . . . . . 29
Fan Belts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Fan Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Fan Pulley Alignment . . . . . . . . . . . . . . . . . . . . . . . . 30
Pulley and Drive Adjustment . . . . . . . . . . . . . . . . . . 30
Condensate Drains . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Return-Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Chilled Water Coil Freeze Protection . . . . . . . . . . . 30
Coil Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Cleaning Cooling Coil . . . . . . . . . . . . . . . . . . . . . . . . 30
Cleaning Insulation . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Replacing Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
START-UP CHECKLIST . . . . . . . . . . . . . . . . . . . . .CL-1
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can be
hazardous due to system pressure and electrical components. Only
trained and qualified service personnel should install, repair, or
service air-conditioning equipment.
Untrained personnel can perform basic maintenance functions of
cleaning coils and filters and replacing filters. All other operations
should be performed by trained service personnel. When working
on air-conditioning equipment, observe precautions in the
literature, tags and labels attached to the unit, and other safety
precautions that may apply.
Follow all safety codes, including ANSI (American National
Standards Institute) Z223.1. Wear safety glasses and work gloves.
Use quenching cloth for unbrazing operations. Have fire
extinguisher available for all brazing operations.
It is important to recognize safety information. This is the safety-
alert symbol
. When you see this symbol on the unit and in
instructions or manuals, be alert to the potential for personal
injury.
Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which
will
result in
severe personal injury or death. WARNING signifies hazards
which
could
result in personal injury or death. CAUTION is used
to identify unsafe practices, which
may
result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which
will
result in enhanced installation, reliability,
or operation.
DANGER
ELECTRICAL SHOCK HAZARD
Failure to follow this warning will result in personal injury or
death.
Before performing service or maintenance operations on unit,
turn off main power switch to unit and install lock(s) and
lockout tag(s). Ensure electrical service to rooftop unit agrees
with voltage and amperage listed on the unit rating plate. Unit
may have more than one power switch.
WARNING
UNIT OPERATION AND SAFETY HAZARD
Failure to follow this warning could cause personal injury,
death and/or equipment damage.
R-410A refrigerant systems operate at higher pressures than
standard R-22 systems. Do not use R-22 service equipment or
components on R-410A refrigerant equipment.
40RU 07-16
Packaged Air-Handling Units
with Puron
®
(R-410A) Refrigerant
60 Hz
Содержание 40RU 07-16
Страница 4: ...4 Fig 2 Dimensions Sizes 07 12...
Страница 5: ...5 Fig 2 Dimensions Sizes 07 12 cont...
Страница 6: ...6 Fig 3 Dimensions Size 14 and 16...
Страница 7: ...7 Fig 3 Dimensions Size 14 and 16 cont...
Страница 27: ...27 Fig 18 Typical Fan Discharge Connections for Multiple Fan Units Fig 19 Duct Flange Installation...