background image

8

TIMER FUNCTION

TIMER ON (to start the unit) and TIMER OFF (to stop the unit)
can be used separately or together.

Timer ON only

This function allows the unit to start automatically at the set time.

The TIMER ON can be set while the unit is on or off.

UNIT ON

a. Press the TIMER ON

button to initiate the auto-on time

sequence. The set time is displayed in the remote control
display. Every time the TIMER ON button is pressed, the

time increases by 30 minutes, up to 10 h. It increases by 60
minutes, afterwards, until the time setting reaches 24 h.

b. When the TIMER ON is set, the TIMER light on unit

illuminates. The unit continues to run at the set time.

UNIT OFF

a. Set the timer described in the UNIT ON section.

b. The unit starts at the set time.

Adjust the TIMER ON settings to 0.0 to cancel this option.

Timer OFF only

This function allows the unit to stop automatically at the set time.

The timer can be set while the unit is on or while it is off.

UNIT ON

a. Press the TIMER OFF

button to initiate the auto--off time

sequence. The set time appears on the remote control display.
Every time the TIMER OFF button is pressed, the time
increases by 30 minutes, up to 10 h. It increases by 60

minutes, afterwards, until the time settings reach 24 h.

b. When the TIMER OFF is set, the timer light on the unit

illuminates and the unit turns off automatically at the set time.

UNIT OFF

a. Set the TIMER off as described in the UNIT ON section.

The TIMER display on the unit illuminates and the unit
remains off.

b. Adjust the TIMER ON settings to 0.0 to cancel this option.

Timer ON and Timer OFF

Use both functions to program the unit to turn on and shut off at
specified times.

UNIT OFF

a. Set TIMER ON as previously described.

b. Set TIMER OFF as previously described. The unit starts

automatically at the set TIME ON and turns off at the set

TIME OFF.

UNIT ON

a. Set TIME OFF as previously described.

b. Set TIME ON as previously described. The unit turns off

automatically at the set TIME OFF and turns on at the set
TIME ON.

Sleep Mode

SLEEP mode is used to conserve energy and can be used when the

unit is in the COOL, HEAT or AUTO mode only.

Cool Mode

a. Push the SLEEP button. After 1 hour the set point raises

by 1.8

_

F (1

_

C). After another hour, the set point raises by

another 1.8

_

F (1

_

C) and the fan runs in a low speed. The

unit shuts off 5 hours after setting the SLEEP mode. The

SLEEP mode cancels if either the “Mode”, “TEMP”,
“Fan”, “Timer”, or “On/Off” buttons on the remote control

is pressed.

Heat Mode

Same as cooling mode however set points are lowered by 1.8

_

F

(1

_

C).

Turbo Mode

Use the TURBO mode to cool or heat the room rapidly.

a. Press the TURBO button. An audible “beep” is heard if the

indoor unit supports this function. The fan runs on super high
speed. The TURBO mode terminates automatically 20

minutes after pushing the Turbo mode button. It can be
terminated immediately by selecting the Turbo mode again.

When the Turbo mode is terminated, the unit reverts to the
original setting.

Self Clean Mode

Press the “Self Clean” button to activate or deactivate the

self--cleaning function. Under this function, the air conditioner

automatically cleans and dries the evaporator. The cleaning cycle
takes 30 minutes, after which the unit turns off automatically. Press

SELF CLEAN

on the middle of the cycle cancels the operation

and turn off the unit. This function can be activated only on

COOL or DRY mode.

Follow Me Mode

Press the “Follow Me” button to activate or deactivate this

function. Under this setting, the temperature that appears in the
remote control is the actual temperature at its location. The remote

control sends this signal to the air conditioner every 3 minutes.

This function is not available for DRY and FAN modes.

Freeze Protection Mode

Press the “FP” button for approximately 2 seconds to activate or
deactivate the freeze protection mode (heating set back). The

indoor unit displays “FP”.

NOTE: This function is only available in the heating mode.

Under this function, the unit operates at high fan speed and the coil

temperature automatically sets to 46

_

F (8

_

C). This mode can also

be deactivated by pressing the “On/Off”, “Sleep”, “Mode”, “Fan”,

or either “TEMP” buttons.

Silence Mode

NOTE: The Silence Mode (SLC Button) is not available on this
model.

LED Light

Press the LED button to turn the display light on and off.

Resetting the Remote Control

If the batteries in the remote control are removed, the current settings
will be cancelled and the control returns to the initial settings and will

be in standby mode. Push the ON/OFF button to activate it.

Time Delay

If the On/Off button is pressed too soon after a stop, the

compressor will not start for 3 to 4 minutes due to the inherent
protection against frequent compressor cycling. The unit only

emits an audible beep when the signals are received correctly.

Heating Features

If the unit is in the heating mode, there is a delay when the fan

starts. The fan starts only after the coil is warmed up to prevent
cold blow.

Auto Defrost Operation

In heating mode, if the outdoor coil is frosted, the indoor fan and
outdoor fan turns off while the system removes the frost on the

outdoor coil. The system automatically reverts to normal operation
when frost is removed from the outdoor unit.

Auto Start

If the power fails while the unit is operating, the unit stores the

operating condition, and it will start operation automatically under

those conditions when the power is restored.

Содержание 40MBF/38MAQ

Страница 1: ...your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFORMATION Model ___________________________________ Serial ___________________________________ INSTALLATION INFORMATION Date Installed _____________________________ DEALERSHIP CONTACT INFORMATION Company ...

Страница 2: ...ng and or heating the floor console fan coil unit matched with an outdoor condensing unit filters and dehumidifies the air in the room to provide maximum comfort IMPORTANT The floor console fan coil unit should be installed by authorized personnel only using approved tubing and accessories If technical assistance service or repair is needed contact the installer The floor console fan coil unit can...

Страница 3: ...3 PART NAMES A150654 Fig 1 Indoor Outdoor Unit ...

Страница 4: ...s the ON and OFF settings of the TIMER Displayed by pressing the ON OFF button Press the ON OFF button again to remove Displays the selected fan speed AUTO no display and three fan speed levels LOW HIGH can be indicated The fan speed is AUTO when the operating mode is either AUTO or DRY MED Displayed under sleeping operation Press the SLEEP button again to remove Note All indicators shown in the f...

Страница 5: ...ntrol must be reprogrammed after insertion of new batteries Remote Control Operation Quick Start NOTE When transmitting a command from the remote control to the unit be sure to point the control toward the right side of the unit The unit confirms receipt of a command by sounding an audible beep 1 Turn the unit on by pushing the ON OFF button 2 If there is a preference for _C rather than _F default...

Страница 6: ...ature is lower than the room temperature Selecting the Fan Speed AUTO LOW MED HIGH A14362 Fig 8 Fan Speeds The fan speed can be selected by pressing the FAN button NOTE When the unit is on the fan runs continuously in cooling or heating When in heating there might be situations where the fan will slow down or shut off to prevent cold blow Selecting the Horizontal Direction Louver Position To optim...

Страница 7: ...y determines the appropriate blowing pattern based on the operating mode or situation Table 1 Operating Mode OPERATING MODE COOL MODE HEAT MODE Situation When the room totally cools or when one hour has passed since turning on the air conditioner At the start of the operation or other times when the room is not totally cooled At times other than below normal time At the start or when the air tempe...

Страница 8: ...pidly a Press the TURBO button An audible beep is heard if the indoor unit supports this function The fan runs on super high speed The TURBO mode terminates automatically 20 minutes after pushing the Turbo mode button It can be terminated immediately by selecting the Turbo mode again When the Turbo mode is terminated the unit reverts to the original setting Self Clean Mode Press the Self Clean but...

Страница 9: ...age to the coil fins Air Filters Remove and clean the air filters once a month NOTE If air filters show signs of excessive wear or are torn they must be replaced Contact your local dealer for replacement filters 1 Open the front panel A150660 Fig 14 Open the Front Panel 2 Remove the air filter A150661 Fig 15 Remove the Air Filter 3 Remove the carbon filter Hold the frame s tabs and remove the four...

Страница 10: ...ries S S S S OUTDOOR UNIT EVERY MONTH EVERY 6 MONTHS EVERY YEAR Clean Outdoor Coil from Outside Clean Outdoor Coil from Inside Blow Air Over Electric Parts Check Electric Connection Tightening Clean Fan Wheel Check Fan Tightening Clean Drain Pans S S S S S S S Increase frequency in dusty zones Maintenance to be carried out by qualified service personnel Refer to the Installation Manual Table 3 Tro...

Отзывы: