23
Multipliers for Determining the Performance With Other Indoor Sections.
See notes on pg. 25.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
–3
7
17
27
37
47
57
67
EDB CFM
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Total Int*
Kw† Total Int*
Kw† Total Int*
Kw† Total Int*
Kw† Total Int*
Kw† Total Int*
Kw† Total Int*
Kw† Total Int*
Kw†
38YZA042-30 Outdoor Section With FX4ANF042 Indoor Section
65
1225 18.7 17.2 2.86 22.4 20.6 2.94 26.5 24.1 3.04 30.9 27.4 3.15 35.9 32.7 3.28 41.4 41.4 3.43 40.7 40.7 3.64 39.9 39.9 3.57
1400 19.0 17.5 2.93 22.7 20.9 2.98 26.9 24.5 3.06 31.3 27.8 3.16 36.4 33.1 3.27 42.1 42.1 3.40 41.4 41.4 3.59 40.6 40.6 3.50
1575 19.2 17.7 3.01 23.0 21.1 3.05 27.2 24.8 3.11 31.7 28.2 3.19 37.0 33.6 3.28 42.6 42.6 3.39 42.0 42.0 3.57 41.3 41.3 3.47
70
1225 18.5 17.1 2.99 22.2 20.4 3.08 26.2 23.9 3.19 30.5 27.1 3.31 35.4 32.3 3.46 40.8 40.8 3.61 40.1 40.1 3.83 39.2 39.2 3.75
1400 18.8 17.3 3.06 22.5 20.7 3.13 26.6 24.3 3.22 31.0 27.5 3.32 36.0 32.7 3.44 41.5 41.5 3.58 40.8 40.8 3.78 40.0 40.0 3.68
1575 19.1 17.5 3.14 22.8 21.0 3.19 26.9 24.6 3.26 31.4 27.9 3.35 36.5 33.2 3.45 42.1 42.1 3.57 41.4 41.4 3.76 40.7 40.7 3.64
75
1225 18.4 16.9 3.12 22.0 20.2 3.23 26.0 23.7 3.36 30.2 26.8 3.49 35.0 31.9 3.64 40.3 40.3 3.80 39.5 39.5 4.03 38.5 38.5 3.94
1400 18.9 17.4 3.20 22.3 20.5 3.28 26.3 24.0 3.38 30.7 27.2 3.49 35.5 32.3 3.62 40.9 40.9 3.76 40.2 40.2 3.98 39.3 39.3 3.87
1575 18.9 17.4 3.27 22.6 20.8 3.34 26.7 24.3 3.42 31.1 27.6 3.52 36.0 32.8 3.63 41.5 41.5 3.75 40.8 40.8 3.95 40.0 40.0 3.83
Indoor
Section
Size
Heating
Indoor
Section
Size
Heating
Capacity
Power
Capacity
Power
FX4ANF
042
1.02
1.01
COILS + 58MVP080-20 VARIABLE SPEED FURNACE
40FKA/FK4CNF
003
0.99
1.00
CD5AA
048
1.00
1.01
005
0.99
0.93
CJ5A/CK5A/CK5BA
048
1.00
1.01
CC5A/CD5AC
048
0.98
1.08
CK3BA
048
1.00
1.01
CC5A/CD5AW
048
1.00
1.02
COILS + 58MVP100-20 VARIABLE SPEED FURNACE
CD3(A,B)A
048
1.00
1.02
CD5AA
048
1.00
1.00
CD5A/CD5BA
048
1.00
1.02
CJ5A/CK5A/CK5BA
048
1.00
1.00
CE3AA
048
1.02
1.04
CJ5A/CK5A/CK5BW
048
1.00
1.01
CJ5A/CK5A/CK5BA
048
1.02
1.03
CK3BA
048
1.00
1.00
CJ5A/CK5A/CK5BW
048
1.02
1.03
COILS + 58MVP120-20 VARIABLE SPEED FURNACE
CK3BA
048
1.02
1.03
CC5A/CD5AW
048
1.00
1.00
F(A,B)4AN(F,B,C)
048
1.02
1.03
CJ5A/CK5A/CK5BW
048
1.00
1.00
FC4BN(F,B)
048
1.02
1.02
COILS + 58U(H,X)V080-16 VARIABLE SPEED FURNACE
FV4ANF
003
1.00
1.00
CD5AA
048
1.00
1.01
005
0.99
0.93
CJ5A/CK5A/CK5BA
048
1.00
1.01
COILS + 58MVP040-14 VARIABLE SPEED FURNACE
CK3BA
048
1.00
1.01
CC5A/CD5AW
048
1.00
1.01
COILS + 58U(H,X)V100-20 VARIABLE SPEED FURNACE
CJ5A/CK5A/CK5BW
048
1.00
1.01
CC5A/CD5AW
048
1.00
0.99
COILS + 58MVP080-14 VARIABLE SPEED FURNACE
CJ5A/CK5A/CK5BW
048
1.00
0.99
CD5AA
048
1.00
1.01
COILS + 58U(H,X)V120-20 VARIABLE SPEED FURNACE
CJ5A/CK5A/CK5BA
048
1.00
1.01
CC5A/CD5AW
048
1.00
0.99
CK3BA
048
1.00
1.01
CJ5A/CK5A/CK5BW
048
1.00
0.99
Heat pump heating performance continued