EN
ENGLISH
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
2
Shield pipe
Air filte
r
Hook
Hook
(Atta
ch to
the f
ront p
anel.)
65 mm or more
170 m
m or more
100 mm or more
600 mm or more
B m
m o
r mo
re
600 mm or more
A m
m o
r m
ore
1
Installation
plate
Saddle
Extension
drain hose
(Not available,
provided by installer)
170 mm or more
Vinyl tape
Apply after carrying
out a drainage test.
5
Filter
6
Filter
Wall
Do not allow the drain hose to
get slack.
Make sure to run the drain
hose sloped downward.
Cut the piping
hole sloped
slightly.
The auxiliary piping can be
connected to the left, rear left,
rear right, right, bottom right
or bottom left.
Insulate the refrigerant pipes
separately with insulation, not
together.
6 mm thick heat resisting
polyethylene foam
For the rear left and left piping
Insert the cushion between
the indoor unit and wall, and
tilt the indoor unit for better
operation.
Rear
left
Left
Bottom left
Right
Rear right
Bottom
right
2
Wireless remote control
4
Remote control holder
8
Pan head
wood screw
Fixing bolt arrangement of outdoor unit
Optional Installation
Parts
Parts name
Refrigerant piping
Liquid side :
∅
6.35 mm
Gas side
:
∅
9.52 mm (42HQV025,
42HQV035)
:
∅
12.70 mm (42HQV045)
Pipe insulating material
(polyethylene foam, 6 mm thick)
Putty, PVC tapes
Q’ty
One
each
1
One
each
Part
code
A
B
C
38VYX025
38VYX035,
38VYX045
A
400 mm
600 mm
B
45 mm
100 mm
Remark :
•
Detail of accessory and installation
parts can see in the accessory sheet.
3
Batteries
600 mm
90 mm
125 mm
115 mm
32.5 mm
73 mm
102 mm
310 mm
7 mm
3
0
500 mm
97 mm
60 mm
275 mm
•
Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be
exposed to a strong wind.
•
Use
∅
8 mm or
∅
10 mm anchor bolts and nuts.
•
If it is necessary to drain the defrost water, attach drain nipple
9
and cap
water proof
!
to the bottom plate of the outdoor unit before installing it.
Drain outlet
Air outlet
Air inlet
38VYX025
Air outlet
Air inlet
Drain outlet
38VYX035, 38VYX045