38VYM 

R-410A

GB - 4

• Carefully recover refrigerant within this unit before final disposal or

when servicing. Never vent refrigerant to atmosphere.
Use approved recovery equipment for R-410A refrigerant.
Do not use R-22 equipment.
The unit must then be delivered to an appropriate disposal center
or to the original equipment dealer.

• When lifting the unit, never use hooks inserted in the side

handles, use special equipment (e.g. lifting devices, trolleys,
etc.).

Choosing the installation site

Positions to avoid:
• Exposed to direct sun.
• Too close to sources of heat radiation, vapour or flammable gas.
• Particularly dusty areas.

Recommendations:
• Choose a position protected from opposing winds.
• Choose a position sheltered from direct sun.
• Choose an area where air outlet and unit noise will not bother

your neighbours.

• Choose a position that allows for the clearances required.
• Floor structure should be adequately strong to support unit weight

and minimize vibration transmission.

• Consider a position which will not obstruct passageways or doors.

• For heat pump models, unit must be adequately raised above

floor surface.

• To drain the condensate water to a drain while operating in

heating mode, insert the drain fitting into the hole underneath on
the left of the basin and use a vinyl pipe with a 16 mm internal
diameter. It must not be used at temperatures lower than 0

°

C.

• If the unit is installed in areas where heavy snowfalls may

occur, it is necessary to raise its level at least 200 mm
above the usual snow level or alternatively use the outdoor
unit bracket kit.

General information

Unit installation

R-410A systems operate at higher pressures than standard
R-22 systems. Do not use R-22 service equipment or
components on R-410A equipment.

Read this instruction manual thoroughly before starting the
installation.

• This unit complies with low-voltage (EEC/73/23) and electro-

magnetic compatibility (EEC/89/336) directives.

• Check that the impedance of the mains power supply is in

conformance with the unit power input indicated in the
electric data table III, on page 11 (EN 61000-3-11).

• The installation must be carried out by a qualified installer.

• Follow all current national safety code requirements. In

particular ensure that a properly sized and connected ground
wire is in place.

• Check that voltage and frequency of the mains power supply are

those required; the available power must be adequate to operate
any other possible appliances connected to the same line.
Also ensure that national safety code requirements have been
followed for the mains supply circuit.

• The  mains supply must be connected to the outdoor unit.

• Connect indoor and outdoor units with field-supplied copper

pipes by means of flare connections. Use insulated seamless
refrigeration grade pipe only, (Cu DHP type according to
ISO1337), degreased and deoxidized, suitable for operating
pressures of at least 4200 kPa and for burst pressure of at
least 20700 kPa. Under no circumstances must sanitary type
copper pipe be used.

• After installation thoroughly test the system operation and explain

all system functions to the owner.

• Leave this manual with the owner for consultation during future

periodic maintenance.

• Use this unit only for factory approved applications: the unit is

suitable for outdoor installation.

• This installation manual describes the installation procedures of

the outdoor unit of a residential split system consisting of units
manufactured by Carrier. Consult the Carrier stockist to check the
possibility of connecting your multisplit unit to indoor units other
than those foreseen by the manufacturer. Do not connect this unit
to any other manufacturer's indoor unit. Coupling units which have
different control systems, may cause irreversible damage and void
the warranty protection. The manufacturer declines any liability for
system malfunction resulting from unapproved coupling.

IMPORTANT:
During unit installation make first refrigerant connections and
then electrical connections. If the unit is uninstalled first
disconnect electrical cables, then refrigerant connections.

WARNING:
Disconnect the mains power supply switch before servicing
the system or handling any internal parts of the unit.

• The manufacturer declines any liability for damage resulting from

modifications or errors in the electrical or refrigerant connections.

• Failure to observe the installation instructions or use of the unit

under conditions other than those indicated in Table II “Operating
limits”, will immediately void the unit warranty.

• Failure to observe electric safety codes may cause a fire hazard in

case of short circuits.

• Inspect equipment for damage due to improper transportation or

handling: file an immediate claim with the shipping company.
Do not install or use damaged units.

• In case of any malfunctioning turn the unit off, disconnect the

mains power supply and contact a qualified service engineer.

• This equipment contains R-410A refrigerant, a substance that

does not deplete the ozone layer.

• All manufacturing and packaging materials used for your new

appliance are compatible with the environment and can be
recycled.

• Dispose of the packaging material in accordance with local

requirements.

100 mm min.

mm gradient

Gravel-filled trench.

Snow

Drain fitting

Vinyl pipe

Содержание 38VYM Series

Страница 1: ...38VYM L L O Y D S R E G I S TER QUALIT Y A S S U R A N C E IS O 900 1 R 410A INSTALLATION MANUAL...

Страница 2: ...70 higher than R 22 Be sure that servicing equipment and replacement components are designed to operate with R 410A R 410A refrigerant cylinders are pink R 410A refrigerant cylinders have a dip tube...

Страница 3: ...A mm 800 800 800 B mm 590 800 800 C mm 300 300 300 D mm 508 508 508 E mm 146 146 146 F mm 330 330 330 kg kg 50 64 65 38VYM 28 38VYM 32 Model 38VYM 18 28 32 A mm 100 100 100 B mm 250 250 250 C mm 500...

Страница 4: ...s designed with chargeless specification For 38VYM 28 and 38VYM 32 models connection of only one indoor unit is not allowed Two or more units must be connected A4 A3 A2 A1 H Table I Connections 38VYM...

Страница 5: ...owed for the mains supply circuit The mains supply must be connected to the outdoor unit Connect indoor and outdoor units with field supplied copper pipes by means of flare connections Use insulated s...

Страница 6: ...wet before connection Disconnecting the refrigerant connections after installation as this will cause refrigerant leaks Connecting the condensate drain pipe to the outdoor unit Predominant head winds...

Страница 7: ...otect copper tubes during storage Use tools designed for R 410A higher pressure Keep inside clean 2 stage vacuum pump Replace oil regularly No moisture No dust No leak No mineral oil Neat Dry nitrogen...

Страница 8: ...the wall using the bracket kit Connect tubing in accordance with the limits shown on Table II Connections Finger tighten the fitting several turns then tighten it with a wrench by applying the tighten...

Страница 9: ...vacuum with a vacuum pump connected to the service connection of the suction shut off valve as shown keeping the shut off valves completely shut until a 50 Pa 0 5 mbar vacuum has been reached Now ope...

Страница 10: ...1 2 3 A1 A2 1 2 3 1 2 3 A3 A4 A3 1 2 3 Terminal box legend Earth L Live power supply N Neutral power supply 1 Connection indoor outdoor unit 2 Connection indoor outdoor unit 3 Connection indoor outdo...

Страница 11: ...th L Live power supply N Neutral power supply 1 Connection indoor outdoor unit 2 Connection indoor outdoor unit 3 Connection indoor outdoor unit Indoor unit Outdoor unit Main switch Time delay fuse or...

Страница 12: ...rs to indoor unit A4 This only refers to model 38VYM 32 Make certain the refrigerant pipes and the electrical connection lines between the indoor unit and the outdoor unit have the same colours and re...

Страница 13: ...as flashing turns OFF Reconnect the red connector At the end of the test if there is a fault code the yellow LED D800 flashes and the red LEDs that indicate the defect remain ON see table The compress...

Страница 14: ...posal in this case after removal the unit must be delivered to an appropriate disposal centre or the original dealer Shut off the liquid valves with the Allen wrench Turn the indoor units ON in coolin...

Страница 15: ...io 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice Order No 13812 74M10 January 2003 Supersedes Order No 13812 74M10...