Carrier 38QH30-C Скачать руководство пользователя страница 10

9

10. PART LIST OF OUTDOOR UNIT 

QTY./UNIT

38QH-H 38QH-C

SR.

DESCRIPTION

PART 

NUMBER

30 36 30 36 

COMPRESSOR COMPLETE WITH GROMMETS & SPACERS 

 

 

 

 

 

1.1 Copeland 

Comp. 

CR37KQ-PFT 

01500256 

 

 

1.2 Copeland 

Comp. 

CR47KQ-PFZ 

01500172 

 

 

2 COND. 

BASE 

08107402 

SUPPORTING LEG ASSY 

36314043 

4 COND. 

PARTITION 

06307407 

 

 

06307436  

 

CONDENSER COIL SUBASSY. 

 

 

 

 

 

5.1  Cond. Coil 2 Row – 33.15” x 22” - 14FPI 

02600234 

 

 

5.2  Cond. Coil 2 Row – 33.15” x 28” - 15FPI 

02600231 

 

 

CONDENSER MOTOR SUPPORT SUBASSY. 

36313880 

7 CONDENSER 

MOTOR 

 

 

 

 

 

7.1  Motor 1/10 HP-880 RPM 

02400154 

 

 

7.2  Motor 1/5 HP-860 RPM 

02400179 

 

 

PROPELLER C/W SOCKET SET SCREW 8 X 8 MM 

02600441 

9 ORIFICE 

PROPELLER 

02803112 

10

 COND. 

SHROUD 

08107406  1   1  
06307435  

 

21 CARRIER 

LOGO 

02900615 

12 HANDLE 

 

02803110 

13 

GUARD PROPELLER  

02803113 

14 

COND. BACK PANEL  

06307409 

 

 

  

06307434 

 

 

15 COUPLING 

PANEL 

06307410 

16 SERVICE 

DOOR 

02803106 

17 COIL 

GUARD 

02803114 

 

 

  

02803115 

 

 

18 COND. 

COVER 

 

08107400 

19 

ELECTRICAL BOX SUBASSY 

36314125 

 

 

 

36314097  

 

 

36314223  

 

 

36314222  

 

 

19.1 DUAL 

CAPACITOR 

 

 

 

 

 

 

19.1.1 Dual Capacitor 50 + 5 MFD/440 VAC  

02400379 

 

 

 

19.1.2 Dual Capacitor 60 + 5 MFD/440 VAC 

02400377 

 

 

19.2  CONTACTOR FOR COMPRESSOR 

 

 

 

 

 

 

19.2.1 Contactor 2 poles – 25 Amps 

02400580 

 

 

 

19.2.2 Contactor 2 poles – 30 Amps 

02400572 

 

 

19.3 TERMINAL 

BLOCKS 

 

 

 

 

 

 

19.3.1 Terminal Block 6 Poles-30 Amps 

02501433 

 

 

 

19.3.2 Terminal Block 4 Poles-30 Amps 

02501405 

 

 

 

19.3.3 Terminal Block 3 Poles-30 Amps 

02501315 

19.4  COND. ELECTRICAL BOX 

06307405 

19.5 CAPACITOR 

CLAMP 

02804078 

19.6 SUPPORT 

CABLE 

02802523 

19.7  WIRE HARNESS SET 

02500879 

 

 

  

02500872 

 

 

19.8  PTC STARTER FOR COMPRESSOR 

 

 

 

 

 

 

19.8.1 PTC Starter Model SPP POW-R-PAK 

02501579 

 

 

 

19.8.2 PTC Starter Model SPP5 

02501578 

 

 

19.9  LOW PRESSURE CONTROL 

02400638 

19.10  PILOT LIGHT FOR LOW PRESSURE CONTROL 

02502315 

20 

REVERSING VALVE & ELECTRIC COIL 

 

 

 

 

 

02200404 1 

   

02200406  

 

 

21 ACCUMULATOR 

02301012 

 

 

 

  

02301013 

 

 

 

22 

SENSOR – OUTDOOR COIL 

02503015 

 

 

23 TUBING 

36314124 

 

 

 

36314096  

 

 

36313934  

 

 

36314193  

 

 

Содержание 38QH30-C

Страница 1: ...2005 SERVICE MAINTENANCE MANUAL...

Страница 2: ...ions 5 7 Exploded View of Indoor Unit 6 8 Part List of Indoor Unit 7 9 Exploded View of Outdoor Unit 9 10 Part List of Outdoor Unit 10 11 Wiring Diagrams 11 12 Field Electrical Connections Matching 13...

Страница 3: ...egligence 2 Failure due to Accident Weather Natural catastrophe accident due to bad weather Hail Storm Sand Storm lightning Flooding Acid Rain and Air Borne fallout etc 3 Failure due to Damages during...

Страница 4: ...d temperature timer and swing and sleep functions b OUTDOOR UNIT x Mounted outside the space to be air conditioned x It contains compressor fan motor condenser coil copper tubing and electrical compon...

Страница 5: ...6303188 H 42QH30 C 46303186 C 42QH36 H 46303189 H 42QH36 C 46303187 C OUTDOOR UNIT Heat Pump Cool Only Model P N ID Model P N ID 38QH30 H 46302173 H 38QH30 C 46302179 C 38QH36 H 46302177 H 38QH36 C 46...

Страница 6: ...Cold draft prevention Indoor fan off Heating mode During unit operation Defrost cycle Indoor fan off Heating mode During unit operation Indoor coil Freeze protection Compressor off Cooling mode Durin...

Страница 7: ...6 7 EXPLODED VIEW OF INDOOR UNIT 23 22 22 20 21 19 18 17 16 15 14 13 10 11 12 9 6 7 4 3 2 7 5 8 1 25 24 5 24 6 24 4 24 7 24 3 24 2 24 1...

Страница 8: ...6 17 Bar Gang 02802431 4 4 4 4 18 Deflector with Arm 02802429 4 4 4 4 19 Evap Coil 3R x 5C x 3 8 02600159 1 1 1 1 20 Frame Grille 02802436 1 1 1 1 21 Screw Cover 02802400 4 4 4 4 22 Air Filter 0280240...

Страница 9: ...8 9 EXPLODED VIEW OF OUTDOOR UNIT 18 5 2 9 8 6 10 12 13 7 1 14 16 15 4 20 3 11 17 20 19 5 19 2 19 3 19 3 19 1 19 6...

Страница 10: ...1 1 17 COIL GUARD 02803114 1 1 02803115 1 1 18 COND COVER 08107400 1 1 1 1 19 ELECTRICAL BOX SUBASSY 36314125 1 36314097 1 36314223 1 36314222 1 19 1 DUAL CAPACITOR 19 1 1 Dual Capacitor 50 5 MFD 440...

Страница 11: ...10 INDOOR UNIT 42QH H SERIES HEAT PUMP WIRING DIAGRAM INDOOR UNIT 42QH C SERIES COOL ONLY WIRING DIAGRAM 11 WIRING DIAGRAMS 0350151...

Страница 12: ...11 OUTDOOR UNIT 38QH H SERIES HEAT PUMP WIRING DIAGRAM OUTDOOR UNIT 38QH C SERIES COOL ONLY WIRING DIAGRAM WIRING DIAGRAMS CONT...

Страница 13: ...Earth L Live power supply N Neutral power supply 6 Live connection indoor outdoor unit 5 Neutral connection indoor outdoor unit 4 Compressor control 3 Reversing valve control Only for heat pump syste...

Страница 14: ...13 13 REFRIGERATION CYCLE HEAT PUMP SYSTEM...

Страница 15: ...14 REFRIGERATION CYCLE Cont COOL ONLY SYSTEM...

Страница 16: ...or timer led as per malfunction 14 2SELF DIAGNOSTIC FUNCTION The self diagnostic function included in the control system detects malfunctions of the following components 1 Return Air Sensor 2 Indoor...

Страница 17: ...ANING Open the return grille without removing the two screws and the central clamp from their position Remove acrylic fiber filters for cleaning CLEANING OF ACRYLIC FIBRE STANDARD FILTERS First clean...

Страница 18: ...it Every Month Every 4 Months Every Year Clean air filter 1 Clean drain pipe 2 Change controller batteries Outdoor Unit Every Month Every 4 Months Every Year Clean outdoor coil from outside 2 Clean ou...

Страница 19: ...Outdoor fan stopped Detective run capacitor Faulty fan motor of outdoor section Restriction in refrigerant system Capillary or Accurate restricted or ice clogged Blow refrigerant evacuate system and r...

Страница 20: ...or have the wrong polarity Replace batteries or check polarity When pressing the recessed lock adjustment button hour figures on display do not flash Recessed button has not been pressed correctly Pre...

Страница 21: ...ation after having removed the obstacles Receiver on the indoor unit or the remote control is under intense sum radiation Avoid direct sun on the unit shut curtains or shades When pressing any functio...

Страница 22: ...coming from the indoor unit Unpleasant smells can be caused by substances accumulated in the air filters Switch the system OFF and contact an authorized service center to have the filters cleaned Res...

Отзывы: