Fig. 8-4-6
FILE NO. SVM-10031
Wire type : H07RN-F or more
Use stranded wire only.
NOTE
Taking out the power cord
•
Put the power supply cord through the notch.
For the air conditioner with the power supply cord
CAUTION
· If the power supply cord is damaged, it must
be replaced by the manufacturer, the service
agency, or another similarly qualified person
in order to avoid hazard.
Stripping length of the power supply cord
Earth line
N
L
40 mm
10 mm
30 mm
10 mm
<How to connect the connecting cable>
Wiring of the connecting cable can be carried out
without removing the front panel.
1.
Remove the air inlet grille.
Open the air inlet grille upward and pull it toward
you.
2.
Remove the terminal cover and cord clamp.
3.
Insert the connecting cable (according to the local
cords) into the pipe hole on the wall.
4.
Take out the connecting cable through the cable
slot on the rear panel so that it protrudes about
15 cm from the front.
5.
Insert the connecting cable fully into the terminal
block and secure it tightly with screws.
6.
Tightening torque : 1.2 N·m (0.12 kgf·m)
7.
Secure the connecting cable with the cord clamp.
8.
Fix the terminal cover, rear plate bushing and air
inlet grille on the indoor unit.
CAUTION
•
Be sure to refer to the wiring system diagram
labeled inside the front panel.
•
Check local electrical cords and also any specific
wiring instructions or limitations.
8-4-4. Wiring connection
<How to install the air inlet grille on the indoor unit>
•
When attaching the air inlet grille, the contrary of
the removed operation is performed.
Fig. 8-4-7
Earth line
Terminal
block
Cord clamp
Screw
Screw
Screw
Power cord connect cover
Power supply cord
3
1
2
Air inlet grille
Front panel
Notch
Wire type : H07RN-F or more
Use stranded wire only.
NOTE
80 mm
10 mm
10 mm
10 mm
70 mm
50 mm
Connecting
cable
Terminal cover
Cord clamp
Terminal block
Earth line
Connecting
cable
Screw
Screw
about 15 cm
Earth line
Stripping length of
the connecting cable
Screw
−
33
−