23
DIMENSIONS − Y − TYPE BRANCH TUBE KIT KSAUI0501AAA
(LIQUID AND GAS TUBES INCLUDED WITH THE KIT)
.51 in. (12.9mm)
.63 in. (16.1mm)
.62 in. (15.9mm)
2.63 in. (67mm)
.47 in.
(12mm)
.94 in.
(24mm)
11.03 in. (281mm) ± .20 in. (5mm)
.76 in. (19.2mm)
.63 in. (16.1mm)
.51 in. (12.9mm)
.38 in. (9.7mm)
.51 in. (12.9mm)
.63 in. (16.1mm)
.62 in. (15.8mm)
.59 in.
(15mm)
.59 in.
(15mm)
2.13 in. (54mm)
9.53 in. (242mm) ± .20 in.(5mm)
3.347 in. (85 mm)
.47in.
(12mm)
.94 in.
(24mm)
.98 in.
(25mm)
.94 in.
(24mm)
.79 in.
(20mm)
.39 in.
(10mm)
Unit: in (mm)
Fig. 20 – Branch Pipe − Gas Pipe
2.36 in (60mm)
.26 in (6.5mm)
.26 in (6.5mm)
.38 in (9.7mm)
.38 in (9.7mm)
ni
1
3. (8mm)
ni
1
7. (18mm)
ni
1
7. (18mm)
ni
7
4. (12mm)
)
m
m
5
6(
ni
6
5.
2
)
m
m
5(
.
ni
0
2.
±)
m
m
4
3
1(
ni
8
2.
5
.38 in (9.7mm)
.
ni
5
3.
)
m
m
9(
)
m
m
5(
ni
0
2.
±
)
m
m
3
7
1(
ni
1
8.
6
125°
Fig. 21 – Branch Pipe − Liquid Pipe
Содержание 38GJQ Series
Страница 16: ...16 DIMENSIONS INDOOR CONT 8 4 in 215mm 23 6in 600mm 27 5in 700mm 7 87in 200mm Fig 7 Floor Console Dimensions...
Страница 19: ...19 DIMENSIONS OUTDOOR CONT Fig 12 Outdoor Dimensions Size 48 56...
Страница 25: ...25 CLEARANCES INDOOR CONT Fig 24 Ducted Clearance Fig 25 Floor Console Clearance...