12
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
Low-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit.
† Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations are determined
under DOE computer simulation procedures.
‡ Based on computer simulation. TXV must be Puron compatible and hard shutoff type.
** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Carrier furnaces are equipped with TDR except for the 58GFA.
†† Indoor Airflow
‡‡ Must replace factory-supplied R-22 TXV with Puron TXV.
UNIT SIZE-
SERIES
INDOOR
UNIT
ARI STANDARD RATINGS*
Cooling
Heating
TC
Seasonal Efficiency SEER
EER
High-Temp
Low-Temp
HSPF
Factory-
Supplied
Enhance-
ment
Standard
Rating
Field-Supplied
Accessory‡
Puron
TXV
Puron TXV
& TDR**
TC
COP
TC
COP
060-30, 31,
50
FX4ANB060† 57,000
TDR+TXV
12.00
—
—
9.95
60,000
3.34
37,800
2.38
7.80
40FKA/FK4CNB006
57,500
TDR‡‡
—
12.50
—
10.50
59,500
3.44
37,000
2.46
8.00
FB4ANB070
57,000
TDR
—
12.00
—
9.95
60,000
3.34
37,800
2.38
7.80
FC4BNB070
57,000
TDR‡‡
—
12.00
—
9.95
60,000
3.34
37,800
2.38
8.00
FV4ANB006
57,500
TDR+TXV
12.50
—
—
10.50
59,500
3.44
37,000
2.44
8.00
CC5A/CD5AW060
55,000
NONE
—
—
12.00
9.80
59,000
3.10
37,000
2.28
7.50
CK5A/CK5BX060
55,000
NONE
—
—
12.00
9.95
59,000
3.26
37,200
2.34
7.60
COILS + 58U(H,X)V100-20 VARIABLE SPEED FURNACE
CC5A/CD5AW060
55,000
TDR
—
12.50
—
10.10
58,000
3.16
36,600
2.32
7.50
CK5A/CK5BX060
56,500
TDR
—
12.50
—
10.35
59,000
3.32
36,800
2.40
7.80
COILS + 58U(H,X)V120-20 VARIABLE SPEED FURNACE
CC5A/CD5AW060
55,000
TDR
—
12.00
—
9.90
58,000
3.12
36,800
2.28
7.50
CK5A/CK5BX060
56,000
TDR
—
12.50
—
10.20
59,000
3.30
37,000
2.38
7.80
SEER — Seasonal Energy Efficiency Ratio
TC — Total Capacity (Btuh)
COP — Coefficient of Performance
TDR — Time-Delay Relay
HSPF — Heating Seasonal Performance Factor
TXV — Thermostatic Expansion Valve
EER — Energy Efficiency Ratio
Combination ratings* continued