– 37 –
FILE NO. SVM-05010
8-2. Installation Diagram of Indoor and Outdoor Units
For installation of the indoor unit, use the paper pattern
Shield pipe
Air filte
r
Hook
Hook
65 mm or more
1
Installation
plate
170 mm
or more
For the rear left and left
piping
Insert the cushion between
the indoor unit and wall, and
lift the indoor unit for better
operation.
Wall
The auxiliary piping can be
connected the left, rear left,
rear, right or bottom.
Insulate the refrigerant
pipes separately with
insulation, not together.
6 mm thick heat resisting
polyethylene foam
Left
Rear left
Right
Rear
Bottom
170 mm
or more
Do not allow the drain hose
to get slack.
Cut the piping
hole sloped
slightly
Make sure to run the drain
hose sloped downward.
6
Nano-silver filter
(Atta
ch to the f
ront panel) (Attac
h to the air filter)
Pan head wood screw
4
Remote control holder
Before installing the
wireless remote control
• With the remote control cover
open, load the batteries supplied
correctly, observing their
polarity.
2
Wireless remote control
3
Batteries
2
Wireless remote control
5
Nano-Photo filter
8
on the back of the installation manual.
18 Class Heat pump 24 Class
100 m
m or
m ore
600 m
m
or m
ore
600
mm
or
mo
re
600
mm
or
mo
re
600 m
m
or m
ore
600 m
m
or m
ore
100 m
m or
m ore
600 mm or more
600 mm or more
10
0 m
m
or
m
or
e
Electric
parts cover
Extension
drain hose
(Not available,
provided by
installer)
Saddle
Vinyl tape
Apply after carrying
out a drainage test.
100 mm
or
m
ore
Extension
drain hose
(Not available,
provided by
installer)
18 Class Cooling
Loop the connecting cable (about 100 mm
in diameter and 300 - 350 mm long).
Electric
parts cover
Loop the connecting cable (about 100 mm
in diameter and 300 - 350 mm long).