background image

Installation Instructions

Part No. 30HW900007

SAFETY CONSIDERATIONS

Installing, starting up, and servicing air-conditioning equip-

ment can be hazardous due to system pressures, electrical
components, and equipment location.

Only trained, qualified installers and service technicians

should install, start up, and service this equipment.

When working on air-conditioning equipment, observe pre-

cautions in the literature and on tags, stickers, and labels at-
tached to the equipment.

ELECTRICAL SHOCK HAZARD
To avoid the possibility of electrical shock,
open all disconnects before installing or
servicing this equipment.

GENERAL

The accessory sound enclosure package consists of a set

of insulated sheet metal panels for mounting on 30HW units,
in order to achieve additional sound reduction where needed.
After all panels are mounted, the compressor compartment
will be completely enclosed with sound insulation panels.

Check Package Contents —

Check package for miss-

ing parts or shipping damage. If damage is found, or any
part is missing, file a claim with the shipper immediately.
See Table 1.

Table 1 — Accessory Package Contents

ITEM

DESCRIPTION

PART NO.

QTY

1

Insulated Basepan

Assembly (perforated)

30HW400027

4

2

Support Angle

30HW500020

4

3

Insulated Side

Panel Assembly

35

7

8

x 26

3

4

in.

(911 x 679 mm)

30HW400023

2

4

Insulated Front/Rear

Panel Assembly

30 x 26

3

4

in.

(762 x 679 mm)

30HW400025

2

5

Self-Tapping Screws

1

4

-20 x

3

4

in. long

AK92AB168

40

NOTE: Insulated basepans (Item 1) are constructed of 16-gage per-
forated steel plate.

INSTALLATION

To avoid the possibility of personal injury, obtain as-
sistance when installing this equipment. A minimum of
2 persons is required.

Step 1 — Read Instructions Carefully

before pro-

ceeding with installation. See Fig. 1 and 2 for proper ori-
entation of assembled parts.

30HWA, HWB018-040

Accessory Sound Enclosure

50/60 Hz

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 2
Tab

5c

PC 903

Catalog No. 563-003

Printed in U.S.A.

Form 30HW-2SI

Pg 1

9-93

Replaces: New

Содержание 30HWA Series

Страница 1: ...ge for miss ing parts or shipping damage If damage is found or any part is missing file a claim with the shipper immediately See Table 1 Table 1 Accessory Package Contents ITEM DESCRIPTION PART NO QTY 1 Insulated Basepan Assembly perforated 30HW400027 4 2 Support Angle 30HW500020 4 3 Insulated Side Panel Assembly 357 8 x 263 4 in 911 x 679 mm 30HW400023 2 4 Insulated Front Rear Panel Assembly 30 x...

Страница 2: ... cut away areas permit the insulated basepan assembly to fit around the control box conduit on one side and around the suction and discharge tubes on the other side The remaining 2 in sulated basepan assemblies for the unit lower section do not require any modification UNIT UPPER BASEPAN WITH PRE DRILLED SCREW HOLES CUT AWAY INSULATION SLOT 1 PRE DRILLED SCREW HOLES UPPER SUPPORT ANGLE ONE EA SIDE...

Страница 3: ...anels to Unit Bottom Section IMPORTANT If you removed the factory installed 100 or 200 amp non fused disconnect switch described in Step 2 it must be mounted on the insulated side panel Item 3 using the pre drilled mounting holes located near the bottom center of the panel When mounting the panel be sure it is turned so that the mounting holes are toward the bottom of the panel Remount the disconn...

Страница 4: ...NEL MOUNTED INSULATED SIDE PANEL 30 IN 762 mm 26 3 4 IN 679 mm Fig 6 Installing Insulated Front Rear Panels to Bottom Section Copyright 1993 Carrier Corporation Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations Book 2 Tab 5c PC 903 Catalog No 563 003 Printed in U S A Form 30HW 2SI Pg 4 9 93 Replaces New ...

Отзывы: