
4
EQUIPMENT SIZING GUIDELINES
If primary load is cooling, size the same as any other air conditioning system. If primary load is heating, use the chart below for maximum
size for heating.
MAXIMUM RECOMMENDED EQUIPMENT SIZE -- HEATING
COOLING LOAD (tons)
MAXIMUM RECOMMENDED EQUIPMENT SIZE FOR HEATING*
2
36
2.5
36
3
48
3.5
60
4
60
5
60
* Make sure duct work is capable of delivering required airflow . Make sure combination rating exists for desired combination.
MIN/MAX AIRFLOW TABLES
The indoor airflow delivered by this system varies significantly
based on outdoor temperature, indoor unit combination, and
system demand. The airflows on these tables are for duct design
considerations. Duct systems capable of these ranges will ensure
the system will deliver full capacity at all outdoor temperatures.
Minimum and maximum airflows can be adjusted from these
numbers in the Infinity Control Heat Pump Setup screen.
Cooling --- Comfort Mode
Minimum Cooling
(Dehum or Zoning)
Size
Max Capacity
Min Capacity
24
726
651
398
36
1168
651
398
48
1394
1186
693
60
1650
1186
693
Cooling --- Efficiency Mode
Size
Max Capacity
Min Capacity
24
949
830
36
1334
830
48
1593
1355
60
1885
1355
Heating --- Comfort Mode
Size
Max Capacity
Min Capacity
24
698
440
36
1140
451
48
1354
751
60
1354
751
Heating --- Efficiency Mode
Size
Max Capacity
Min Capacity
24
900
750
36
1350
750
48
1600
890
60
1750
901
25V
N
A
Содержание 25VNA
Страница 8: ...8 DIMENSIONS ENGLISH 25VNA ...
Страница 9: ...9 DIMENSIONS SI 25VNA ...