TESTED AHRI* COMBINATION RATINGS

NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory

www.ahridirectory.org

Additional ratings and system combinations can be accessed via the Carrier database at:

www.MyCarrierRatings.com

For performance data at specific application &/or design conditions with various indoor unit combinations, the
equipment performance calculator can be accessed at :

http://rpmob.wrightsoft.com/

Model Number

Coil Model Number

Furnace

Model

Number

Cooling

Capacity

EER

SEER

High Temp

HSPF

Low Temp

Capacity

47

˚

F (8

_

C)

COP

Capacity

17

˚

F ( ---8

_

C)

COP

25HCD318(A,W)**30

FB4CNF018

17,400

11.0

13.0

16,700

3.60

7.7

9,400

2.24

25HCD324(A,W)**30

FB4CNF024

23,400

11.0

13.0

22,000

3.48

7.7

13,000

2.28

25HCD330(A,W)**30

FB4CNF030

28,600

11.0

13.0

29,600

3.50

7.7

17,700

2.34

25HCD330(A,W)**50

FB4CNF030

28,600

11.0

13.0

29,600

3.50

7.7

17,700

2.34

25HCD336(A,W)**31

FB4CNF036

33,600

11.0

13.0

33,000

3.50

7.7

20,200

2.40

25HCD336(A,W)**50

FB4CNF036

33,600

11.0

13.0

33,000

3.54

7.7

20,200

2.40

25HCD336(A,W)**60

FB4CNF036

33,600

11.0

13.0

33,000

3.54

7.7

20,200

2.40

25HCD342(A,W)**31

FB4CNF042

42,000

11.0

13.0

39,500

3.60

8.0

24,400

2.40

25HCD342(A,W)**50

FB4CNF042

42,000

11.0

13.0

39,500

3.62

8.0

24,000

2.44

25HCD348(A,W)**31

FB4CNF048

47,000

11.0

13.0

45,000

3.48

8.0

28,600

2.44

25HCD348(A,W)**50

FB4CNF048

47,000

11.0

13.0

45,000

3.58

8.0

28,200

2.50

25HCD348(A,W)**60

FB4CNF048

47,000

11.0

13.0

45,000

3.58

8.0

28,200

2.50

25HCD360(A,W)**30

FY5BNB060

58,500

10.8

13.0

57,000

3.52

7.7

37,000

2.50

25HCD360(A,W)**50

FY5BNB060

58,500

10.8

13.0

57,000

3.52

7.7

37,000

2.50

25HCD360(A,W)**60

FY5BNB060

58,500

10.8

13.0

57,000

3.52

7.7

37,000

2.50

*

AHRI = Air Conditioning, Heating & Refrigeration Institute

* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:

Cooling Standard:

80

_

F (27

_

C) db 67

_

F (19

_

C) wb indoor entering air temperature and 95

_

F (35

_

C) db air entering outdoor unit.

High---Temp Heating Standard:

70

_

F (21

_

C) db indoor entering air temperature and 47

_

F (8

_

C) db 43° F (6

_

C) wb air entering outdoor unit.

Low---Temp Heating Standard:

70

_

F (21

_

C) db indoor entering air temperature and 17

_

F (---8

_

C) db 15° F (---9

_

C) wb air entering outdoor unit.

COP

— Coefficient of Performance

EER

— Energy Efficiency Ratio

HSPF

— Heating Seasonal Performance Factor

SEER

— Seasonal Energy Efficiency Ratio

25

HCD3

Содержание 25HCD3

Страница 1: ...ion system S Indoor air quality accessories available Sound S Sound level as low as 69 dBA S Sound levels as low as 69 dBA with accessory sound blanket Comfort S System supports Edger Thermidistatt or...

Страница 2: ...M Mark indicates a manufacturer s participation in the program For verification of certification for individual products go to www ahridirectory org STANDARD FEATURES Feature 18 24 30 36 42 48 60 Puro...

Страница 3: ...e avoiding excessive capacity loss The suction line diameters shown in the chart below are acceptable for HP systems with Puron refrigerant Vapor Line Sizing and Cooling Capacity Losses Puronr Refrige...

Страница 4: ...0 250 250 250 250 24000 HP with Puron 3 8 250 250 250 250 250 250 250 30000 HP with Puron 3 8 250 250 250 250 250 250 250 36000 HP with Puron 3 8 250 250 250 250 250 250 250 42000 HP with Puron 3 8 25...

Страница 5: ...X X X X X KHALS0401LLS SOLENOID VALVE X X X X X X X X X X X X X X KHASS0606MPK SNOW STAND RACK X X X X X X X X X X X X X KSASH0601COP SOUND BLKT X X X X X X X X X X X X KSASH2101COP SOUND BLKT X X KA...

Страница 6: ...mproves compressor lubrication on restart and minimizes the chance of liquid slugging Usage Guideline Required in low ambient cooling applications Required in long line applications Suggested in all c...

Страница 7: ...allow for drainage from unit base Usage Guideline Suggested in the following applications Heat pump installations in heavy snowfall areas Heat pump installations in snow drift locations Heat pump ins...

Страница 8: ...OTE Control circuit is 24 V on all units and requires external power source Copper wire must be used from service disconnect to unit All motors compressors contain internal overload protection Complie...

Страница 9: ...9 DIMENSIONS ENGLISH 25HCD3...

Страница 10: ...10 DIMENSIONS SI 25HCD3...

Страница 11: ...0 80 10 0 0 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 kW BUILDING HEAT LOSS UNIT INTEGRATED HEATING CAPACITY MBTUH OUTDOOR TEMPERATURE 25HCD324 FB4CNF024 25HCD330 FB4CNF030 25HCD336 FB4CNF036 25HCD360...

Страница 12: ...2 24 609 6 Service 6 152 4 12 304 8 24 609 6 Service 24 609 6 Service 24 609 6 Service Note Numbers in mm 18 457 2 18 457 2 12 304 8 IMPORTANT When installing multiple units in an alcove roof well or...

Страница 13: ...13 0 33 000 3 54 7 7 20 200 2 40 25HCD342 A W 31 FB4CNF042 42 000 11 0 13 0 39 500 3 60 8 0 24 400 2 40 25HCD342 A W 50 FB4CNF042 42 000 11 0 13 0 39 500 3 62 8 0 24 000 2 44 25HCD348 A W 31 FB4CNF048...

Страница 14: ...88 11 57 1 28 20 86 11 27 1 44 19 69 10 90 1 62 18 34 10 46 1 82 16 73 9 90 2 04 14 63 9 20 2 23 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES F C 75 23 9 85 29 4 95 35 105 40 6 115 46 1 125 51 7...

Страница 15: ...2 2 35 66 17 95 2 19 34 05 17 45 2 42 32 19 16 87 2 69 30 14 16 21 2 99 27 89 15 49 3 33 25 30 14 64 3 72 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES F C 75 23 9 85 29 4 95 35 105 40 6 115 46 1...

Страница 16: ...22 2 51 25 27 56 3 02 49 14 26 89 3 39 46 67 26 10 3 81 43 93 25 24 4 25 40 90 24 23 4 73 37 53 23 06 5 25 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES F C 75 23 9 85 29 4 95 35 105 40 6 115 46...

Страница 17: ...02 39 75 7 46 72 22 2 72 25 37 51 4 66 68 77 36 22 5 11 65 08 34 87 5 61 61 18 33 45 6 17 56 96 31 94 6 81 52 49 30 36 7 54 2250 57 13 9 61 41 61 41 4 61 58 94 58 94 5 06 56 30 56 30 5 57 53 46 53 46...

Страница 18: ...83 10 51 1 33 14 25 12 96 1 37 16 64 16 64 1 41 18 48 18 48 1 45 19 85 19 85 1 47 INDOOR AIR OUTDOOR COIL ENTERING AIR TEMPERATURES F C 3 19 4 7 13 9 17 8 3 27 2 i8 37 2 8 47 8 3 57 13 9 67 19 4 EDB F...

Страница 19: ...32 21 33 18 95 2 38 24 75 22 52 2 43 28 47 28 47 2 48 32 48 32 48 2 52 35 27 35 27 2 55 INDOOR AIR OUTDOOR COIL ENTERING AIR TEMPERATURES F C 3 19 4 7 13 9 17 8 3 27 2 i8 37 2 8 47 8 3 57 13 9 67 19...

Страница 20: ...1 77 3 12 28 69 25 48 3 18 34 39 31 29 3 27 38 75 38 75 3 29 43 56 43 56 3 29 48 57 48 57 3 25 INDOOR AIR OUTDOOR COIL ENTERING AIR TEMPERATURES F C 3 19 4 7 13 9 17 8 3 27 2 i8 37 2 8 47 8 3 57 13 9...

Страница 21: ...43 65 43 5 01 72 49 72 49 5 17 2000 24 22 22 28 4 16 30 94 28 43 4 27 37 68 34 36 4 36 44 80 39 79 4 49 52 40 47 68 4 65 58 81 58 81 4 79 66 40 66 40 4 93 73 04 73 04 5 08 2250 24 72 22 74 4 23 31 51...

Страница 22: ...scharging air upward Condenser fan motors will be totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Shafts will be corrosion resistant Fan blades will be static...

Страница 23: ...rconnecting refrigerant tube lengths greater than 80 ft 23 4 m and or elevation differences between indoor and outdoor units greater than 20 ft 6 1 m consult Residential Piping and Longline Guideline...

Страница 24: ...orp S 7310 W Morris St S Indianapolis IN 46231 Edition Date 03 13 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No 25H...

Отзывы: