3–11
62-11640
3.7
CHANGING SETPOINT
1. Verify that the system is powered up (START/RUN-OFF switch in the START/RUN position) or in PC Mode
and the default screen displayed (press the Back soft key if required):
2. Press the
▲
or
▼
key to bring the displayed setpoint to the desired value.
TIP
The setpoint will change one degree with each press and release of an Arrow key or the setpoint will
scroll if the key is pressed and held.
3. Press the “=” key to save the new setpoint. The MessageCenter will display “SETPOINT CHANGED” for 10
seconds.
4. If the “=” key is not pressed the setpoint screen will flash, the MessageCenter will display “SETPOINT NOT
CHANGED” and then return to original setpoint.
By default, setpoints of -22°F to +95°F (-30°C to
+35°C) may be entered using the display mounted
keys. The control system always retains the last
entered setpoint in memory. The setpoint will change
1° (one full degree)
OR
0.1° (one tenth of a degree - if
configured to do so) for each press and release of the
UP ARROW or DOWN ARROW key.
NOTE
The control system may be configured with a
minimum and/or maximum setpoint other
than the default values listed above. “MAX
SETPOINT HAS BEEN REACHED” or “MIN
SETPOINT HAS BEEN REACHED” will dis-
play in the MessageCenter when either of
these conditions is reached.
Setpoint may be changed any time the START/RUN -
OFF switch is in the START/RUN position, or when the
unit is in PC Mode EXCEPT when:
• Viewing the Alarm List, Data List or Functional
Parameters
OR
• When the unit is in Pretrip
OR
• When the unit is in Sleep Mode.
Pressing the = key will cause the new displayed set-
point value to become active and “SETPOINT
CHANGED” will be displayed. If the new value is not
entered, after 10 seconds of no display mounted key
activity, the entire display and Light Bar will flash (with
“SETPOINT NOT CHANGED” displayed) and then
revert back to the last entered setpoint. All other keys
are active at this time and if a key is pressed while the
display is flashing, the flashing will stop, and the
requested function will be performed.
TIP
The setpoint may be changed quickly by
pressing and holding the UP ARROW or
DOWN ARROW key until the desired set-
point is reached. The longer the key is held,
the faster the setting will change.
CONTINUOUS
START/STOP
MENU
ALARM
COOL
DIESEL
START/STOP
INTELLISET
Viewing Menu Soft Key
Selections
Press Menu Key to Scroll
PRETRIP HOUR
METERS
UNIT
DATA
DEFROST
IntelliSets (2 of 7)
BACK
EXIT
IntelliSet Off
Banana Active
Flowers
Lettuce
Cheese
PRETRIP MENU
BACK
EXIT
Start Pretrip
View Results of Last Pretrip
COOL
DIESEL
START/STOP
STATUS OK
36
36
.2
BOX TEMPERATURE F
SETPOINT F
2
3
2
Содержание Vector 8500
Страница 23: ...62 11640 1 6 1 3 SAFETY DECALS ...
Страница 24: ...1 7 62 11640 62 03958 ...
Страница 25: ...62 11640 1 8 ...
Страница 26: ...1 9 62 11640 ...
Страница 27: ...62 11640 1 10 ...
Страница 125: ...62 11640 SECTION 6 MESSAGECENTER PARAGRAPH NUMBER Page 6 1 MESSAGECENTER MESSAGES 6 1 ...
Страница 321: ......
Страница 322: ......