background image

42

Adit 3500  - Release 1.6

Quick Start Guide

Basic Configuration

4. Select the 

Enable

 button, to configure the WAN Ethernet up (or in-service).

5. Select the 

Settings

 button. 

6. Set

 Network 

type to

 WAN

.

7. Set 

Internet Protocol 

option (method of IP address assignment).   

8. Select 

OK

 to apply the new settings and exit this window.

9. Select 

OK

 again to return to the 

Network Connections

 window.

Содержание Adit 3500

Страница 1: ...Adit 3500 QUICK START GUIDE Part Number 002 0250 0010 Product Release 1 6 September 2007 ...

Страница 2: ...ate into any medium electronic mechanical magnetic optical chemical manual or otherwise any part of this manual or software supplied with the Adit 3500 for any purpose other than the purchaser s personal use without the express written permission of Carrier Access Corporation The Carrier Access Logo and Adit are registered trademarks of Carrier Access Corporation All other brand or product names a...

Страница 3: ...nting Rack Mounting Battery Backup Chassis Overview Interface Connectors Reset Button Alarm Status LEDs Web Based Management Setting up a CLI Connection Log in Key Enabled Software Features Basic Configuration Web Based Management Restore Factory Defaults Modify Default Admin User Configure WAN Interface for Internet Connectivity Configure the Adit 3500 as a SIP Gateway ...

Страница 4: ...tainer and store in a safe place until ready to install Electrostatic Discharge ESD Precautions ESD can damage processors circuit cards and other electronic components Always observe the following precautions before installing a system component 1 Do not remove a component from its protective packaging until ready to install it 2 Wear a wrist grounding strap and attach it to a metal part of the sy...

Страница 5: ...LOWED TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK AND INJURY TO PERSONS INCLUDING THE FOLLOWING z Do not use this product near water for example near a bathtub washbowl kitchen sink or laundry tub in a wet basement or near a swimming pool z Avoid using a telephone other than a cordless type during an electrical storm There may be a remote risk of electric shock from lightning z Do not use the teleph...

Страница 6: ...RECT CONNECTION TO PUBLIC DIGITAL NETWORKS TO PREVENT EQUIPMENT DAMAGE FROM LIGHTNING SURGES AC INDUCTION OR POWER LINE CONTACT UTILIZE LISTED PRIMARY PROTECTORS AT THE BUILDING ENTRANCE WITH MINIMUM 4 OHM CURRENT LIMITING AND MAXIMUM 600V IMPULSE BREAKDOWN AT 1000V USEC THE ADIT 3500 DS1 PORTS COME EQUIPPED WITH SECONDARY OVERVOLTAGE AND OVERCURRENT PROTECTION THE INSTALLATION IS REQUIRED TO MEET...

Страница 7: ...N OF USERS AND SERVICE PERSONNEL REFER TO Grounding the Unit ON PAGE 3 FOR DETAILED INSTRUCTIONS 4 Connect DS1 T1 and Ethernet connections as needed 5 Connect RS 232 connector and connect via HyperTerm on your PC Note With this running before power is enabled you can monitor the boot process 6 Attach PBX and phone line cables 7 Connect Power to the unit 8 Monitor the boot process on your PC when c...

Страница 8: ... with EMI standards FCC Part 15 and ICES 003 Class A Ferrite beads shipped with Adit chassis For additional information on Ferrite beads and their installation on the Adit 3500 please contact Carrier Access Customer Support at 800 786 9929 Ferrite Provided Part Number Intended For 1 large P N 010 0051 Power cable which requires a loop through the bead see drawing 12V Power Cord Loop through Ferrit...

Страница 9: ...own in the illustration above To install the unit to the wall 1 Attach the wall mount brackets to the Adit 3000 with wall attachment flange pointing away from the unit as shown above Attach with 4 screws provided 2 for each bracket 2 Mount the unit to the wall using appropriate mounting screws not included Note it is acceptable to mount on drywall with suitable anchor type mounting screws NOTE The...

Страница 10: ...ws on each side The Mounting Ears can be used for both a 19 or 23 inch rack The drawing below shows a top view of the 2 versions 2 Attach the Rack Mounting Tray assembly with mounting ears attached to rack using four 10 32 x 1 4 screws two on each mounting ear 3 Remove wall mount and screws if attached from Adit 3500 unit Note Adit 3500 and wall mounting bracket are not assembled from the factory ...

Страница 11: ...s removed in step 2 5 Slide the assembled piece Adit 3000 and Tray Slide onto the installed Rack Mounting Tray 6 Secure the Tray Slide to the Rack Mounting Tray with the attached screws on the Tray Slide NOTE The mounting brackets are designed to not allow units to be mounted closer than recommended Tray Slide screws screws ...

Страница 12: ...or wall mounting Installation There are two possible configurations to wall mount the Adit 3500 and the Battery Backup NOTE It is recommended that the BBU be mounted to a wooden backboard using 4 6 screws or to drywall using 4 6 screws with anchors These screws are not provided 1 Battery Backup attached to wall with Adit 3500 mounted on the Battery Backup 2 Adit 3500 and Battery Backup attached to...

Страница 13: ... slip over screw head z Attach the BBU by slipping the screw heads through the keyhole slots of the BBU and let unit drop slightly to allow screwheads to enter top of the keyhole z Screw bottom 2 screws into mounting holes at the bottom of the unit z Tighten all screws to the wall 2 Attach Adit 3500 Wall Mounting Brackets to the BBU Note Brackets are provided with the Adit 3500 unit z Each bracket...

Страница 14: ... BBU and brackets z Each bracket attaches to the side of the Adit 3500 Note the orientation of the Adit in the graphic 5 Attach power cords z Connect cord from BBU to the Adit 3500 2 pin connector z Connect 12V power cord to Adit 3500 Front of Adit Screws into side of Adit Second bracket here ...

Страница 15: ...ng the screw heads through the keyhole slots at the left of the BBU and slide unit to the right to allow screwheads to enter the narrow end of the keyhole z Screw the second set of 2 screws into mounting holes on the right of the unit z Tighten all screws to the wall 2 Insert Adit 3500 Power cord through the holder on the top of the BBU This supports the weight of the adapter portion of the power ...

Страница 16: ... hard wired to the Adit 3500 Battery Backup and connects the Adit 3500 Chassis Overview The following illustrations show all connectors on the Adit 3500 Pinout Wire Definition Red 12V Black 12V 2 10 100Base T 4 DS1 E1 4 Analog FXS connectors Alarm Status Reset RS 232 Management Port Power Ground Back Front Battery E1 Future ...

Страница 17: ...onnector Back of Adit z RS 232 craft port connector for local management z Power input connector z Battery input connector z Ground connector Grounding the Unit WARNING THE ADIT 3500 IS REQUIRED TO BE PERMANENTLY GROUNDED FOR THE PROTECTION OF USERS AND SERVICE PERSONNEL Chassis ground is located on the back of the unit To ground the unit 1 Connect a minimum 14 AWG ground wire with a 8 ring tongue...

Страница 18: ...y Backup on page 10 for additional information Item Specification Input Rate input voltage AC100V 240V Vibration input voltage range AC90V 255V Frequency Rated 50 60 Hz Frequency Vibration 47 63Hz Input rated current 15A max at 115VAC cool start 30A max at 230VAC cool start Leakage current 0 25mA Efficiency 70 Min Output Output voltage 13 5VDC Output max current 2 2A 150mA V out 9VDC 13VDC Output ...

Страница 19: ...follows left LED only Pin Name Description 1 Receive Ring Receive from DS1 network 2 Receive Tip Receive from DS1 network 3 N C Not connected 4 Transmit Ring To DS1 network 5 Transmit Tip To DS1 network 6 8 N C Not connected State Description Off Off line Green Normal Red Loss of Signal LOS Yellow Bipolar Violation BPV Flashing Green Loopback active Flashing Yellow Yellow Alarm Remote Alarm Indica...

Страница 20: ...nout you will need a straight cable to connect to a PC The LEDs are as follows Pin Name Description 1 Receive Receive from network 2 Receive Receive from network 3 Transmit Transmit to network 4 5 N C Not connected 6 Transmit Transmit to network 7 8 N C Not connected LED State Description Left LED The left LED shall show Link Status Off Link Down Green Link Up Flashing Green Traffic on Link Yellow...

Страница 21: ...e Adit 3500 The pinouts are as follows RJ 11 Connector There are four RJ 11 female connectors for the FXS ports The pinouts are as follows Reset Button The system can be reset by pressing the reset button located on the front panel Pin Direction Description 1 Outbound Carrier Detect 2 Outbound Receive Data 3 Inbound Transmit Data 4 Inbound Data Terminal Ready 5 N A Signal Ground 6 Outbound Data Se...

Страница 22: ...LOF DS1 LOS WAN fault Ethernet fault and dead card alarms Minor Off No minor alarms present Red Minor alarms present Minor alarms include user configured manor environmental inputs DS1 excessive line code violations Status Off No power to system Green Application running no detected system problems Green Flashing Power On Self Test POST successful System booted Loading Application Green Yellow Fla...

Страница 23: ...te to display the current IP address of the systems use the following CLI command show interface ethernet 1 LAN show interface ethernet 2 Eth WAN 3 Login to the unit Enter User Name and Password Note these setting should be changed from the default settings after the initial login z Default user name is admin z Default password is admin 123 NOTE After a few minutes of inactivity the session will a...

Страница 24: ...ram to access the CLI This requires an IP address of the unit Note to display the current IP address of the unit use the ifconfig command z If connecting via RS 232 the port settings should be set to Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow control None z Set your Terminal Emulation to VT100 NOTE When using Tera Term Telnet program TCP IP CLI commands will not be recognized ...

Страница 25: ...ase system These features can be purchased with the product or added later as needed These features are enabled via a Software Key example G 729 The number of keyed features may expand with the development of the product therefore to see a list of current keyed features or to purchase a key contact Carrier Access Customer Service or Sales To enter a software key use the following CLI command Synta...

Страница 26: ...ication Version 1 5 0 Compilation Time Thu Jun 14 2007 18 07 22 FPGA Version 1 00 Board Version 5 003 1215 0300 IXP400 Software Release 1_4 SQA4_1 MSP 82530 60 channels Image File Name TGW_v5_05 axf API Version 2 1 0 Source IP Addr 192 168 1 1 Voice Slot 1 FXS Card Present Rev 3 00 Vendor Carrier Access CLEI Code IPMHX00LRA Product Features SIP enabled G729A enabled ...

Страница 27: ...00 as a SIP Gateway Setup Adit 3500 for access via Web Browser The following steps will configure the Adit 3500 to allow access to the Web Browser for configuration through the LAN 1 or WAN 2 10 100Base T Ethernet connections Note for LAN access no additional configuration is required to access the Adit using the web browser To configure the WAN access 1 Connect to the CLI via the DB 9 RS 232 See ...

Страница 28: ... If the unit is not out of the box you may want to verify that the unit is set to defaults Note this will reset the IP address back to the default setting of 192 168 1 1 In the web browser z Select Advanced from the Navigation bar z Select Restore Defaults z Select OK to restore defaults ...

Страница 29: ...ault Admin User For security purposes it is recommended that the Administrator User be changed from the default settings Modify the Administrator User in the web browser z Select Advanced from the Navigation bar z Select Users icon z Select Administrator to open the profile ...

Страница 30: ...you need to have a minimum of one user with Administrative Privileges For users with other access levels use the New User to add additional users on the system Note For security purposes the password should be changed from the default setting z You will be required to login again if you have modified the User Profile that you are logged in with ...

Страница 31: ... z Multiple T1s Multilink z Ethernet WAN Single T1 PPP To configure a single T1 utilizing PPP 1 Select Network Connections from the Navigation bar 2 Select click a T1 Interface from T1 1 T1 4 to configure T1 1 is recommended Note Using T1 1 and the preconfigured Serial 1 makes this configuration very simple If you use T1 2 T1 4 you will need to delete the preconfigured Serial 1 and make a New Conn...

Страница 32: ...ck Start Guide Basic Configuration 3 Select the Settings button 4 Set the proper Framing Type and Line Coding 5 Select OK to apply the new settings and exit this window 6 Select OK again to return to the Network Connections window ...

Страница 33: ...Adit 3500 Release 1 6 33 Quick Start Guide Basic Configuration 7 Select click the Serial 1 connection 8 Select the Settings button ...

Страница 34: ...et the following on the Configure Serial 1 window Network Type to WAN this is the default setting PPP Authentication to your required preferences 10 Select OK to apply the new settings and exit this window 11 Select OK again to return to the Network Connections window ...

Страница 35: ...Guide Basic Configuration Multiple T1s Multilink To configure Multiple T1s utilizing Multilink PPP 1 Select Network Connections from the Navigation bar 2 Select click a T1 Interface from T1 1 T1 4 to configure 3 Select the Settings button ...

Страница 36: ...g 5 Select OK to apply the new settings and exit this window 6 Select OK again to return to the Network Connections window 7 Repeat steps 1 6 for additional T1s required for the ML PPP 8 Select click the delete icon associated with the Serial 1 connection Select OK to confirm the deletion of this connection ...

Страница 37: ...t 3500 Release 1 6 37 Quick Start Guide Basic Configuration 9 Select click New Connection to create the ML PPP connection 10 Select the Multilink Point to Point Protocol over DS0 Multilink and select Next ...

Страница 38: ...uick Start Guide Basic Configuration 11 Enter User Name and Password 12 Select the T1s for this Multilink and the channel ranges 13 Select Next 14 A summary of the Multilink connection will be displayed If correct select Finish ...

Страница 39: ...500 Release 1 6 39 Quick Start Guide Basic Configuration 15 The new Multilink connection will display on the Network Connections window 16 Select click the Multilink 1 connection 17 Select the Settings button ...

Страница 40: ...t the following on the Configure Multilink 1 window Network Type to WAN this is the default setting PPP Authentication to your required preferences 19 Select OK to apply the new settings and exit this window 20 Select OK again to return to the Network Connections window ...

Страница 41: ...nfigure the WAN utilizing Ethernet feed 1 Select Network Connections from the Navigation bar 2 Select click the delete icon associated with the Serial 1 connection Select OK to confirm the deletion of this connection 3 Select click the Ethernet 2 WAN Ethernet connection to configure ...

Страница 42: ...on to configure the WAN Ethernet up or in service 5 Select the Settings button 6 Set Network type to WAN 7 Set Internet Protocol option method of IP address assignment 8 Select OK to apply the new settings and exit this window 9 Select OK again to return to the Network Connections window ...

Страница 43: ...Adit 3500 Release 1 6 43 Quick Start Guide Basic Configuration Configure the Adit 3500 as a SIP Gateway 1 Select Voice Over IP from the Navigation bar ...

Страница 44: ... 2 On the IP Telephony tab under Proxy Servers Set Proxy Type to Generic custom BroadSoft or Sylantro Example BroadSoft Select Use SIP Proxy and enter SIP Proxy IP address Select supported Codecs 3 Select Apply to save the new settings 4 Select the Advanced button ...

Страница 45: ...Adit 3500 Release 1 6 45 Quick Start Guide Basic Configuration 5 Modify any advanced VoIP settings as needed and select Apply 6 Select OK to exit window ...

Страница 46: ...46 Adit 3500 Release 1 6 Quick Start Guide Basic Configuration 7 If using the FXS ports select the Phone Settings tab 8 Select the Action icon on line 1 to edit ...

Страница 47: ...ation 9 Enter the Phone Number in the User ID field 10 Enter Authentication information as needed 11 Select OK to apply and exit this window 12 Select OK to acknowledge that with these changes active calls will be dropped 13 Repeat this step for each FXS Line ...

Страница 48: ... Select the Line Monitoring tab This window displays the SIP status of the FXS ports Note When a telephone port is successfully registered the Registration Status column displays Registered in green 16 Select the Trunk Settings tab 17 Select click on the trunk to configure 18 Set the Trunk Signaling type to PRI or CAS ...

Страница 49: ...Adit 3500 Release 1 6 49 Quick Start Guide Basic Configuration 19 Set the Signaling Type 20 Select New Entry to assign numbers to your PRI interface s ...

Страница 50: ...P calls on the Call Destination window Use Strip and Prefix entries to translate the incoming destination number from SIP to the destination number to be sent to the PRI CAS interface 22 Select OK to save and exit this window Note this information will display at the bottom of the Trunk Settings window 23 Select OK again to return to the Voice Over IP window ...

Страница 51: ...Adit 3500 Release 1 6 51 Quick Start Guide Basic Configuration 24 Select the Trunk Monitoring tab to view the status of any calls on the PRI ...

Страница 52: ...52 Adit 3500 Release 1 6 Quick Start Guide Basic Configuration ...