Bottom Panel
Fuse
–
In the unlikely event that a tube fails, the amp is protected by a 1 Amp Slow Blow
fuse for 120v and 100v (US and Japan) models, and a 0.5 Amp Slow Blow fuse for 230v-
240v (Europe) models. Please consult us or a qualified tech for further instruction or
assistance in the event of a fuse blowing. The fuse is located on the bottom of the chassis by
the power cord.
Power Tube Bias
– The Raleigh is a self-bias amplifier and does
not
require adjustment
when changing power tubes. The new self- bias arrangement starts with serial number 711
February 2020.
Speaker Output Jack
– The Raleigh is designed for 8-ohm loads. Maximum power and
tone will be realized when running into an 8-ohm speaker or cabinet.
Carr Amplifiers selects and tests the finest current production tubes specifically for each
amplifier model. Caution should be used when buying replacement tubes from any dealer
who does not have a return policy as all tubes can have problems (NOS tubes are
susceptible to microphonics and failure too).