7.
Remove (2) screws securing drip pan using Phillips screwdriver bit as shown
below.
Note: Retain screws.
8.
Pull drip pan downward as shown below.
Note: If necessary use flatblade
screwdriver to pry drip pan down as shown below.
9.
Remove and discard old atomizers using (2) 8″crescent wrenches as shown below.
10.
Install new atomizers.
11.
Reinstall drip pan.
Note: If necessary use flatblade screwdriver to install drip pan.
12.
Secure drip pan with retained (2) screws using Phillips screwdriver bit.
13.
Align tabs on intake diffuser with drip pan.
14.
Secure intake diffuser with retained (4) screws using Phillips screwdriver bit.
15.
Reinstall false floor.