background image

R

(SHEET 2 OF 2)

IS1592B(04/17)

PLUMBERS INSTALLATION INSTRUCTIONS

WATER EFFICIENT TAPWARE

'G' SERIES PLUS- WALL SINK EXPOSED SET

Installing the outlet (Fig.5)

Determine if the outlet (19) is to be fixed or swivel.

1) For a fixed outlet select the retainer (18a) or if 100 restricted

swivel is required select the smaller retainer (18b). Fit the

retainer (18a or 18b) into the spigot groove, as shown.

Ensure suitable lubricant is applied to the retainer &

'O'rings, then carefully slide the outlet (19) onto the spigot

of breech (11). Rotate the outlet (19) to align the hole in the

outlet with the threaded hole in the retainer (18a or 18b) then

fit screw (17a or 17b) and tighten using the 2mm allen key (3).

Important: The correct retainer/screw combination must be

used (18a/17a) or (18b/17b), as shown.

2)

Changing the indicator (Fig.6)

Loosen screw (2) using a 2mm allen key (3) & remove

handle (1). Remove screw (23) & washer (24) using a

3mm allen key. Push out retainer (26) & indicator (25).

1)

2)Push in new indicator (25) followed by retainer (26). Assemble

screw (23) with washer (24) then screw into the retainer (26) &

tighten with the 3mm allen key. Align handle (1) as before then

engage with insert (6) & tighten screw (2) with 2mm allen key (3).

Cleaning the Aerator Insert (Fig.5)

1) Carefully remove housing (20) from outlet tube (19), taking care

    not to damage the decorative finish.

2) Remove 'O'ring (22) & aerator insert (21) from housing (20).

    Check that housing is clean. Deposits of lime can be removed

    by washing in a vinegar solution.

3) Fit aerator insert (21) into housing (20) followed by 'O'ring (22)

    then screw assembly onto outlet tube (19) & tighten securely

    (to prevent removal by hand).

Fig. 6

23

24

25

26

1

2

3

Fig. 5

11

18a

18b

19

20

21

22

Swivel outlet 

'O'Rings

Spigot

OR

Wall/tile face

3

Fixed Outlet 

17a

17b

Отзывы: