Fire Zone
Your Security System has a “FIRE” zone which can be used for fire detection (when connected to a
Smoke/Heat detector) in certain jurisdictions. If fire detection equipment has been added and the audible fire alarm
siren sounds, you should follow your emergency evacuation plans. (NOTE: If you do not yet have emergency plans,
contact your local fire department or Red Cross for suggestions)
If your fire system has been activated, you silence the audible fire alarm siren by entering your code. Once
all smoke has cleared, you
press "star" then seven
[* 7]; this will reset your system. After 10 seconds the “FIRE”
light and the light on the affected smoke detector should turn off. If you are unable to reset the fire system after the
smoke detector chamber has been cleared of smoke, call Carolina for service help at the top the numbers on reverse
side of this sheet.
Understanding Your Siren Sounds
•
Fire: Short burst tone
•
Burglar: Yelp siren
Understanding Your Keypad Control Lights
•
ARMED Turns on (red)
when system is armed; off otherwise. Will keep blinking if your alarm was activated
while you were away.
•
READY Turns on (green)
when all zones are good (or bypassed) and the system is ready to arm; off otherwise.
•
INSTANT Turns on (red)
when the entry/exit zones are instant; off otherwise; work with STAY button.
•
POWER Turns on (red)
when the AC power is on; flashes when battery power is low; off otherwise.
•
FIRE (Red light) Turns on (red)
when a smoke or heat detector is activated; is reset by pressing the RESET
button [*]; flashes/blinks when there is trouble with your fire equipment; off otherwise.
•
SERVICE Turns on (yellow) when your system has detected equipment trouble; otherwise off.
•
ZONES 1-8 Turns on (yellow)
solid when bypassed; blinks when faulted; blinks rapidly if in trouble; off
otherwise.
•
STAY Turns on (green) when interior (motion detector) zones are bypassed.
•
CHIME Turns on (green) when "chime" is on; off otherwise.
•
EXIT Turns on (green) during exit delay; NOTE: light flashes warning during last 10 seconds before arming
•
BYPASS LIGHT Turns on (green) when any zone is bypassed; otherwise off. (Zones bypassed will light solid)
•
CANCEL Use to cancel the previous button you pressed on keypad control panel.
Understanding Your Keypad Control Tones (Beeps)
A sounder is built into the keypad and will sound for the following reasons:
•
One Beep any time any key is pressed.
•
Continuous Beep during entry delay.
•
Pulsing Beep when (a) fire TROUBLE light is lit, or (b) you arm (or disarm) your alarm when the FIRE (or fire
TROUBLE light) is lit, or (c) the “POWER” light is off. To stop the pulsing, enter your code.
•
Three (3) Beeps when trying to arm alarm with a faulted zone (ex: a door is still open).
•
Single, Long Beep A one (1) second beep at the end of the exit delay (to warn you the alarm is now armed).
NOTE: You can change the tone of your keypad. Press
star then zero
[* 0] to enter "tone adjust" mode. Press the one
button [1] for higher sounds, or two [2] for lower. Press the pound button [#] to set your final tone and exit this
mode.
Operating Your Door Chime
To turn your door "chime" on (or off) press the CHIME button. When your chime feature is on, the CHIME button
will be lit (green). The chime feature makes your keypads sound a "chime" each time a perimeter zone (e.g. door) is
opened.
Zone List
Zone 1:
Zone 9:
Zone 2:
Zone 10:
Zone 3:
Zone 11:
Zone 4:
Zone 12:
Zone 5:
Zone 13:
Zone 6:
Zone 14:
Zone 7:
Zone 15:
Zone 8:
Zone 16: