MODELS
VCDK090
I
• VCDK130
I
• VCDK170
I
TYPICAL INSTALLATION
MOUNTING
(New Frame Construction)
12” ROUND DUCT
(OUTLET)
Ventilator
Factory-Shipped
In Straight-Through
Discharge Position.
9-3/8” x 12-3/4” TO
12” ROUND TRANSITIONS
MOUNTING
BRACKETS
CEILING
JOIST
(24” Centers
Shown)
Factory-shipped unit installed in new construction.
12” ROUND DUCT
(Inlet)
12” ROUND DUCT
(Outlet)
Ventilator Factory-Shipped
In Straight-Through
Discharge Position.
9-3/8” x 12-3/4” TO
12” ROUND
TRANSITIONS
MOUNTING
SCREWS
CEILING
JOIST
(24” Centers
Shown)
Factory-shipped unit installed in existing construction.
MOUNTING
(Existing Frame Construction)
FINISHED
CEILING
MATERIAL
IMPORTANT:
Remove shipping tape from damper.
Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork.
Use duct tape to make ductwork connections secure and air-tight.
2
DUCTING OPTIONS
BLOWER DISCHARGE POSITIONS
Horizontal discharge
position. (Factory shipped)
Vertical discharge
position.
DUCT CONNECTOR
(Outlet)
DUCT
CONNECTOR
(Outlet)
DUCT
CONNECTOR
(Intake)
DUCT
CONNECTOR
(Intake)
Housing
Disassembled
& Rotated To Be
Assembled With
Opening As
Shown
TYPICAL INSTALLATION
WIRING - 115V, 60 Hz., 1 Phase
Use U.L. approved connectors to wire per local codes. Connect
ground wire to bottom of conduit box.
UNIT SIZE
WIRE CONNECTION
YELLOW TO L1, ORANGE TO L2
SEPARATE BROWN AND INSULATE
SEPARATE BLUE AND INSULATE
YELLOW TO L1, BROWN TO L2
SEPARATE ORANGE AND INSULATE
SEPARATE BLUE AND INSULATE
YELLOW TO L1, BLUE TO L2
SEPARATE ORANGE AND INSULATE
SEPARATE BROWN AND INSULATE
INSTALL INLINE BETWEEN L2
AND ORANGE, BROWN OR BLUE
CORRESPONDING TO UNIT
SIZE
170
130
090
Speed
Control