MODELS

VCDK090

I

• VCDK130

I

• VCDK170

I

TYPICAL INSTALLATION

MOUNTING

(New Frame Construction)

12” ROUND DUCT

(OUTLET)

Ventilator 

Factory-Shipped

In Straight-Through
Discharge Position.

9-3/8” x 12-3/4” TO
12” ROUND TRANSITIONS

MOUNTING
BRACKETS

CEILING

JOIST

(24” Centers

Shown)

Factory-shipped unit installed in new construction.

12” ROUND DUCT

(Inlet)

12” ROUND DUCT

(Outlet)

Ventilator  Factory-Shipped

In Straight-Through
Discharge Position.

9-3/8” x 12-3/4” TO

12” ROUND 

TRANSITIONS

MOUNTING

SCREWS

CEILING

JOIST

(24” Centers

Shown)

Factory-shipped unit installed in existing construction.

MOUNTING

(Existing Frame Construction)

FINISHED

CEILING

MATERIAL

IMPORTANT:

Remove shipping tape from damper.

Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork.
Use duct tape to make ductwork connections secure and air-tight.

2

DUCTING OPTIONS

BLOWER DISCHARGE POSITIONS

Horizontal discharge

position.  (Factory shipped)

Vertical discharge 

position.

DUCT CONNECTOR

(Outlet)

DUCT 

CONNECTOR

(Outlet)

DUCT 
CONNECTOR
(Intake)

DUCT 
CONNECTOR 
(Intake)

Housing
Disassembled
& Rotated To Be
Assembled With
Opening As
Shown

TYPICAL INSTALLATION

WIRING - 115V, 60 Hz., 1 Phase

Use U.L. approved connectors to wire per local codes.  Connect
ground wire to bottom of conduit box.

UNIT SIZE

WIRE CONNECTION

YELLOW TO L1, ORANGE TO L2
SEPARATE BROWN AND INSULATE
SEPARATE BLUE AND INSULATE
YELLOW TO L1, BROWN TO L2
SEPARATE ORANGE AND INSULATE
SEPARATE BLUE AND INSULATE
YELLOW TO L1, BLUE TO L2
SEPARATE ORANGE AND INSULATE
SEPARATE BROWN AND INSULATE
INSTALL INLINE BETWEEN L2
AND ORANGE, BROWN OR BLUE
CORRESPONDING TO UNIT
SIZE

170

130

090

Speed

Control