DUCTING (Vertical blower discharge)

WARRANTY

ROOF CAP

10” ROUND

DUCT

10” ROUND

DUCT

7-1/2” x 11-1/4” TO
10” ROUND TRANSITION

Typical ductwork connection to a ventilator converted to

right-angle discharge.

Ventilator is designed for continuous operation. If desired, it may
be controlled using an on/off switch or a solid-state, variable
speed control. Follow wiring instructions packed with control, and
adhere to all local and state codes, and the National Electrical
Code.

To clean blower assembly:  

Disassemble two cabinet halves,

unplug blower from housing, remove blower mounting nuts, and
carefully remove blower from housing. Use appropriate vacuum
attachment or a soft cloth and mild soap or detergent to clean
blower discharge area and wheel. DO NOT ALLOW WATER TO
ENTER THE MOTOR. Make sure blower assembly is complete-
ly dry before reinstalling.

Motor is permanently lubricated. Do not oil or disassemble motor.

WARNING:  To reduce the risk of electric shock,
disconnect from power supply before servicing.

3

Seller warrants products manufactured by it and supplied here-
under to be free from defects in materials and workmanship
under normal use and proper maintenance for a period of twelve
months from date of shipment. If within such period any such
products shall be proved to Seller’s reasonable satisfaction to be
defective, such products shall be repaired or replaced at Seller’s
option. Seller's obligation and Buyer’s exclusive remedy hereun-
der shall be limited to such repair and replacement and shall be
conditioned upon Seller’s receiving written notice of any alleged
defects no later than 10 days after its discovery within the war-
ranty period and, at Seller’s option, the return of such products to
Seller, f.o.b. its factory, when such return is feasible. Seller
reserves the right to satisfy its warranty obligation in full by reim-
bursing Buyer for all payments it makes hereunder, and Buyer
shall thereupon return the products to Seller. Seller shall have the
right to remedy such defects.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND

IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WAR-
RANTIES (EXCEPT TO TITLE) INCLUDING BUT NOT LIMITED
TO IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS
FOR A PARTICULAR PURPOSE, PERFORMANCE, OR OTH-
ERWISE, and in no event shall the Seller be liable for claims
(based upon breach of express or implied warranty, negligence,
product liability, or otherwise) for any other damages, whether
direct, immediate, incidental, foreseeable, consequential, or 
special.

Two ways to connect ductwork to a factory-shipped unit.

DUCTING (Straight-through blower discharge)

7-1/2” x 11-1/4” TO

10” ROUND 

TRANSITIONS

10” ROUND 

DUCT

10” ROUND 

ELBOW

WALL 

CAP

10” 

ROUND 

DUCT

ROOF CAP

MODELS

VCDK040

I

• VCDK050

I

• VCDK070

I

USE AND CARE