background image

 #2 Chootoo Road, South Aranguez, San Juan, Trinidad 

Page 3

MODELS • VCDD210

I

 • VCDD330

I

®

WARNING: To reduce the risk of electric shock,

disconnect from power supply before servicing.

To clean grille:

 Use appropriate vacuum attachment or remove

grille  and clean with a soft cloth and mild soap or detergent. Dry

grille thoroughly before reinstalling.

To clean blower assembly:

 Remove either access panel or ceil-

ing grille. Unplug blower assembly. Provide safe support for blower

assembly. Remove blower mounting screws and lift blower assem-

bly out of housing. Gently vacuum housing and blower motor.

Vacuum or gently wash blower wheels and housings. DO NOT AL-

LOW WATER TO ENTER MOTOR. Make sure blower assembly is

completely dry before reinstalling. Replace blower assembly in hous-

ing and plug assembly in. Replace grille and/or access panel.
Motor is permanently lubricated. Do not oil or disassemble motor.

USE AND CARE

Ventilator is designed for continuous operation. If desired, it may be

controlled using an on/off switch or a solid-state, variable speed

control. Follow wiring instructions packed with control, and adhere

to all local and state codes, and the National Electrical Code.

MOUNTING OPTIONS

EXHAUST

ACCESS

PANEL

INTAKE

SLEEPER

1-1/4”

Typical wall mounting with 3/8” threaded fasteners

(by others) through mounting brackets.

Connect electrical power cable to housing with proper connector

for type of cable used. Provide 6” leads inside wiring box.

ELECTRICAL CONNECTIONS

MOTOR

MOTOR

MOTOR

MODEL

VCDD330

I

MODEL

VCDD210

I

SPEED CONTROL

OR SWITCH

SPEED CONTROL

OR SWITCH

LINE IN

120 VAC

60 HZ

LINE IN

240 VAC

60 HZ

1 PHASE

WHITE

GND

BLK

RED

GND

BLK

ACCESSORY INSTALLATIONS

Install damper flap using rod provided.

Snap screw bushings into square openings around intake

opening. Install grille with screws provided.

NOTE:

 If duct flanges around intake opening interfere with installa-

tion, remove them. Make sure that housing is flush with finished

ceiling when ventilator is mounted.

OUTSIDE

DAMPER BUSHING

(Snaps over rod)

INSIDE DAMPER

BUSHING

(Inside of frame)

DAMPER FLAP

(Should open freely)

CABINET FLUSH

CEILING

GRILLE

NUTS

GRILLE

SCREWS

If ventilator will discharge directly outside, install adamper kit to

prevent backdrafts. A grille kit is available for applications where

ventilator is installed with direct or remote room air intake.

ROD

(Inserts into inside bushing)

DUCT FLANGES

DAMPER

GRILLE

SPEED

VIBRATION

MODEL

KIT

KIT

CONTROL HANGER

VCDD210

I

D100

G102

72V / 72W

V104

VCDD330

I

D101

G103

75V

V104

ACCESSORIES

Carnes VCDD210I-330I Inline Cabinet Fan 

Operation & Instructions Manual

Page 3

MODELS • VCDD210

I

 • VCDD330

I

®

WARNING: To reduce the risk of electric shock,
disconnect from power supply before servicing.

To clean grille: Use appropriate vacuum attachment or remove
grille  and clean with a soft cloth and mild soap or detergent. Dry
grille thoroughly before reinstalling.

To clean blower assembly: Remove either access panel or ceil-
ing grille. Unplug blower assembly. Provide safe support for blower
assembly. Remove blower mounting screws and lift blower assem-
bly out of housing. Gently vacuum housing and blower motor.
Vacuum or gently wash blower wheels and housings. DO NOT AL-
LOW WATER TO ENTER MOTOR. Make sure blower assembly is
completely dry before reinstalling. Replace blower assembly in hous-
ing and plug assembly in. Replace grille and/or access panel.

Motor is permanently lubricated. Do not oil or disassemble motor.

USE AND CARE

Ventilator is designed for continuous operation. If desired, it may be
controlled using an on/off switch or a solid-state, variable speed
control. Follow wiring instructions packed with control, and adhere
to all local and state codes, and the National Electrical Code.

MOUNTING OPTIONS

EXHAUST

ACCESS

PANEL

INTAKE

SLEEPER

1-1/4”

Typical wall mounting with 3/8” threaded fasteners

(by others) through mounting brackets.

Connect electrical power cable to housing with proper connector
for type of cable used. Provide 6” leads inside wiring box.

ELECTRICAL CONNECTIONS

MOTOR

MOTOR

MOTOR

MODEL

VCDD330

I

MODEL

VCDD210

I

SPEED CONTROL

OR SWITCH

SPEED CONTROL

OR SWITCH

LINE IN

120 VAC

60 HZ

LINE IN

240 VAC

60 HZ

1 PHASE

WHITE

GND

BLK

RED

GND

BLK

ACCESSORY INSTALLATIONS

Install damper flap using rod provided.

Snap screw bushings into square openings around intake

opening. Install grille with screws provided.

NOTE: If duct flanges around intake opening interfere with installa-
tion, remove them. Make sure that housing is flush with finished
ceiling when ventilator is mounted.

OUTSIDE

DAMPER BUSHING

(Snaps over rod)

INSIDE DAMPER

BUSHING

(Inside of frame)

DAMPER FLAP

(Should open freely)

CABINET FLUSH

CEILING

GRILLE

NUTS

GRILLE

SCREWS

If ventilator will discharge directly outside, install adamper kit to
prevent backdrafts. A grille kit is available for applications where
ventilator is installed with direct or remote room air intake.

ROD

(Inserts into inside bushing)

DUCT FLANGES

DAMPER

GRILLE

SPEED

VIBRATION

MODEL

KIT

KIT

CONTROL

HANGER

VCDD210

I

D100

G102

72V / 72W

V104

VCDD330

I

D101

G103

75V

V104

ACCESSORIES

Carnes VCDD210I-330I Inline Cabinet Fan 

Operation & Instructions Manual

Отзывы: