background image

READ AND SAVE  

THESE INSTRUCTIONS

RESIDENTIAL HUMIDISTAT

OWNERS MANUAL AND  

QUICK REFERENCE GUIDE

MODEL HXHAF

FORM 16763

ISSUED: 07-31-20

Содержание HXHAF

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS RESIDENTIAL HUMIDISTAT OWNERS MANUAL AND QUICK REFERENCE GUIDE MODEL HXHAF FORM 16763 ISSUED 07 31 20...

Страница 2: ...al has been completely read and understood Important Note Disconnect electrical power to the furnace and humidifier before servicing or starting installation Liability Carnes does not accept any liabi...

Страница 3: ...ring ODT 10 Heat Signal Wiring W 10 Automatic External Fan Control Wiring G GF 10 Humidifier Control Wiring H1 H2 10 Wiring Notes Cautions 11 Operation 12 Screen and Menu 12 Home Screen 12 Fan Heat Si...

Страница 4: ...to Heat Only Mode and ON OFF control These settings are the basic setup for most homes and no adjustment is needed to function with your Carnes humidifier out of the box In winter climates it is highl...

Страница 5: ...unt sensor indicate the direction the airflow should pass over the sensor for optimal readings Figure 1 3 Mount the humidistat to a wall or duct in a convenient location that allows easy adjustment to...

Страница 6: ...UMIDISTAT 6 Form 16763 Figure 2 Duct Sensor Location Figure 3 Duct Sensor Connection Hook Up Away From Circuit Board Wire Colors Return Duct Locations for Duct Sensor Outdoor Air Intake Too Close To O...

Страница 7: ...h the humidistat back cover to the wall using 2 screws anchors E Note The duct sensor is not needed for this installation option Outdoor Temperature Sensor When outdoor air temperature is very low con...

Страница 8: ...ation wire distance between sensor and humidistat is less than 200 feet it can measure true outdoor ambient air temperature it is above the expected snow line Do NOT mount the sensor in direct sunligh...

Страница 9: ...pulled out See Figure 4 for example installation CAUTION electrical interference can cause erratic system operation Donotroutetemperaturesensorwiringwithbuildingpowerwiring next to control contactors...

Страница 10: ...d be completed when possible If the fan control wiring is not possible then the humidistat should only be ran in Heat Only Mode as described in the Operation section of this document The wire running...

Страница 11: ...R REMOVE Figure 5 Humidistat Wiring Diagram Wiring Notes Cautions Do not connect duct sensor backwards Always verify the correct placement of the duct sensor terminal to the main humidistat board Veri...

Страница 12: ...rnal duct sensor is unconnected and the on board room sensor is active DUCT The external duct sensor is connected and active Outdoor air temperature sensor is connected and active if unconnected outdo...

Страница 13: ...ll be displayed when the outdoor temperature sensor is installed External fan and heat signals will also be displayed in the top right hand corner of the screen when active Fan Heat Signal Indicators...

Страница 14: ...navigate the menu and the Enter button to select and confirm an option The Setpoint Adjustment option on the Settings screen shown in Figure 7 allows the user to adjust the desired relative humidity s...

Страница 15: ...ing on user preference To save the value press the enter button again The new humidity setpoint should now be shown on the main screen Figure 7 Mode Selection Page While on the Mode Selection Page pre...

Страница 16: ...l ON OFF control turns the humidifier on when the humidity level drops 10 below setpoint and turns the humidifier off 10 above setpoint Modulating control sends a 010 VDC signal to the humidifier to p...

Страница 17: ...t The humidistat fan signal will turn on the furnace fan for three minutes to check the humidity level If below the setpoint the humidistat fan signal will stay on and humidify the space for a maximum...

Страница 18: ...1 WireControlmodeallowstheuserto utilize the humidistat as a control bypass from a smart thermostat This functiongivescontrolofthehumidifiertoasmartthermostatthathasaonewire humidifier control output...

Страница 19: ..._______________________________ ___________________________________________________________ ___________________________________________________________ ________________________________________________...

Страница 20: ...owing two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 448 S Main St PO...