Carmanah 502 Скачать руководство пользователя страница 9

Owner’s Manual | Model 502 

© 2008 Carmanah Technologies Corporation 

Revised: August 2008 

3.5 

Automatic Light Control 

The Automatic Light Control (ALC) function of the Model 502 light monitors the battery voltage and 
reduces the light’s intensity level if the light is not receiving sufficient solar charging to maintain the 
battery voltage. 

If a light is set at the correct intensity setting for the available solar illumination, ALC is not required 
except in unusual circumstances of poor solar illumination. 

If the light is manually set at a higher intensity it will operate at that higher intensity during the summer 
months, but may turn itself down during the winter months in definable steps. If you do not want the 
intensity level reduced automatically, you must turn ALC off; see section 

3.5.1 Turning ALC off or on

 

Disabling ALC while also increasing the light's intensity beyond a sustainable level will 
cause the battery to over-discharge and the light will fail. 

 

3.5.1 

Turning ALC off or on 

Turning ALC off prevents the light from automatically adjusting the intensity level of the programmed flash 
pattern based on the available battery voltage. If ALC is turned off, you must set the required intensity 
level for the light. 

Turning ALC on allows the light to automatically adjust the intensity level of the programmed flash pattern 
based on the available battery voltage. 

Turning ALC Off: 

1.  Transition the light (if required). 

2.  Enter the security code (if required). 

3.  Enter the flash code (if required). 

4.  Enter code 8 0 0 to turn ALC off. 

 

 

 

0

 

0

 

 

 

 

Turning ALC On: 

1.  Transition the light (if required). 

2.  Enter the security code (if required). 

3.  Enter the flash code (if required). 

4.  Enter code 8 0 1 to turn ALC on. 

 

 

 

0

 

1

 

 

 

 

 

Содержание 502

Страница 1: ...OWNER S MANUAL Model 502 Solar LED Light ...

Страница 2: ......

Страница 3: ... 4 Changing the Flash Pattern 8 3 5 Automatic Light Control 9 3 5 1 Turning ALC off or on 9 4 0 Storing a Light 10 4 1 Storage Mode 10 4 2 Sleep Mode 10 4 3 Turn the Light On Manually 10 5 0 Testing the Battery 11 6 0 Recharging a Light 12 7 0 Appendices 13 Appendix A Original Infrared Programmer 13 A 1 Setting up the Programmer 13 Appendix B Frequently Asked Questions 14 Appendix C Glossary of Te...

Страница 4: ...e or check the following settings flash pattern light intensity automatic light control state of charge for the battery In addition to this basic functionality the light also includes the following features Ship mode Conserves power while the product is sealed in a box 24 hour shutdown mode The light turns off after more than 24 hours of darkness has been detected as may happen if the light is pla...

Страница 5: ...4 hours All the previously programmed settings become active when the light is removed from the box Table 2 1 Programmer Buttons describes the buttons for the programmer Table 2 1 Programmer Buttons Button or Symbol Description Use the Start button to initiate a programming sequence Use the Enter button to complete a programming sequence This symbol indicates that a numerical entry is required Tab...

Страница 6: ...ramming instructions for the required function Transition a new light 1 Remove the light from the shipping box and place it in full sunlight or under an incandescent light for at least 3 seconds 2 Move the light into darkness and wait 3 seconds 3 Move the light back into the light 4 While the light is exposed to the light point the programmer at the light and press the Start button when the light ...

Страница 7: ... Single flash from the light Press Enter Single flash from the light Do not press the buttons on the programmer too fast and do not proceed until you see a flash from the light One of the flash patterns described in Table 3 2 Programming Completion displays after the programming sequence is complete The flash pattern indicates whether or not the programming was successful Table 3 2 Programming Com...

Страница 8: ...ogram the new flash pattern by entering the required flash code see Table 3 3 Model 502 Flash Codes where is a number of the flash code Table 3 3 Model 502 Flash Codes Table 3 3 Model 502 Flash Codes Flash Code Flash Character FL1 EC1 FL2 EC2 FL3 EC3 FL4 EC4 FL5 EC5 Effective Intensity cd 000 Off 0 0 001 Fixed 1 0 0 25 055 Fl 2s 0 5 1 5 0 70 064 Fl 4s 0 5 3 5 0 70 066 Fl 4s 1 3 0 80 072 Fl 6s 0 5 ...

Страница 9: ...y you must turn ALC off see section 3 5 1 Turning ALC off or on Disabling ALC while also increasing the light s intensity beyond a sustainable level will cause the battery to over discharge and the light will fail 3 5 1 Turning ALC off or on Turning ALC off prevents the light from automatically adjusting the intensity level of the programmed flash pattern based on the available battery voltage If ...

Страница 10: ...sh pattern using the programmer The storage code is 0 0 0 Use the storage code when the light is being shipped to a location where there is an available programmer for turning the light on the light will be exposed to intermittent light for example it is not sealed in a box the light is being recharged using daylight turning the light off prevents it from turning on at night and using the charge g...

Страница 11: ... needed and enter code 8 1 0 the light will respond with a series of flashes Single flash the state of charge is less than 30 Two flashes the state of charge is greater than 30 but less than 75 Three flashes the state of charge is greater than 75 For information on recharging the light see section 6 0 Recharging a Light Testing the light battery 1 Transition the light if required 2 Enter the secur...

Страница 12: ...ging Alternatives Following the guidelines ensures that the light is charged safely and the battery is kept fully charged over extended storage periods Table 6 1 Battery Storage and Charging Storage Temperature C F Recharge Interval Months 20 or lower 68 or lower 9 25 77 6 30 86 4 35 95 2 5 40 104 1 5 45 or higher 113 or higher 1 To recharge a light turn it off using the storage code and follow th...

Страница 13: ... programming sequence S Use the Channel Up button to end a programming sequence This symbol indicates that a numerical entry is required A 1 Setting up the Programmer The light is not required to be present when setting up the programmer Perform the following steps to setup the infrared programmer 1 Install two AAA batteries 2 Press and hold the Code Search button until the red indicator light lig...

Страница 14: ...nsumed is converted to light rather than heat Q It s been raining a lot here Will my light stop working A A Carmanah light is a solar light and it does require solar energy to work However it can run for 150 hours at full intensity or 600 hours at low intensity without recharging Q My light has stopped working What do I do A If the light does not respond to the programmer does not flash or emits v...

Страница 15: ...dela s brightness at 1 meter s distance 1 lux Nominal Range The luminous range of a light when the meteorological visibility is 18 nm T 0 74 Peak Intensity The maximum brightness a light emits Signal Color The color of the light exiting the light for example red green white defined by its charted chromaticity coordinates or the wavelength of the light in nanometers Vertical Divergence Angle over w...

Страница 16: ...nah Technologies Corporation carmanah com Technical Support customerservice carmanah com Toll Free in Canada and U S 1 877 722 8877 International 1 250 380 0052 Fax 1 250 380 0062 Number 502_53510_Manual_vB 53510 ...

Отзывы: