COMPRESSOR ACCESSORIES

See Tables 18-26 for compressor accessory usage.

Oil Separators

Accessory Kits

NOTE: One (1) kit required per compressor.

Economizers

PCM Controller

NOTES:

1. One Compressor Protection Module package required per

compressor.

2. The interface cable is required to connect the controller module to

a PC or laptop for setup and configuration. The cable is also

required for Field Service to read information from the module.

Compressor Oil

VFD Drive

See Table 23 for VFD Electrical and Physical Data.

Table 17 — Resistance/Temperature Characteristics

TEMPERATURE

RESISTANCE

(OHMS)

C

±C

F

–30

.35

–22

88,480.0

–25

.33

–13

65,205.0

–20

.30

–4

48,536.0

–15

.28

5

36,476.0

–10

.20

14

27,663.0

–5

.20

23

16,325.0

5

.20

41

12,696.0

10

.20

50

9,949.5

15

.20

59

7,855.5

20

.20

68

6,246.0

25

.20

77

5,000.0

30

.20

86

4,028.4

35

.20

95

3,265.7

40

.20

104

2,663.2

45

.20

113

2,184.2

50

.20

122

1,801.2

55

.20

131

1,493.1

60

.20

140

1,243.9

65

.20

149

1,041.4

70

.20

158

875.8

75

.23

167

739.7

80

.26

176

627.6

85

.29

185

534.9

90

.32

194

457.7

95

.35

203

393.3

100

.38

212

339.3

105

.41

221

293.8

110

.44

230

255.3

115

.47

239

222.6

120

.50

248

194.8

Table 18 — Oil Separator Usage

COMPRESSOR

MODEL

PART

NUMBER

TYPE

INLET

DIAMETER

 OIL

CHARGE

(GPM)

06ZC

30XV50092301 Vertical

3.125"

7

06ZF

30XV50122601 Vertical

4.125"

7

06ZJ

30XV80004301 Horizontal

4.50"

8

Table 19 — Accessory Package

PART NUMBER

COMPRESSOR USAGE

06ZC

06ZF

06ZJ

06ZC660001

X

06ZF660001

X

06ZJ660001

X

Table 20 — Economizer Usage

PART NUMBER

COMPRESSOR USAGE

06ZC

06ZF

06ZJ

LL015B044

X

LL015B050

X

LL01SB056

X

Table 21 — PCM Controller Application

PART NUMBER

DESCRIPTION

APPLICATION

6BSB000929

Medium/High Temp. 

Controller Kit

R-134a, R-1234ze,

or R-513A

USB-L

PCM Interface Cable

Cable interface between 

controller and laptop

Table 22 — Compressor Oil Usage

PART NUMBER

USAGE

QUANTITY

P903-2301

Medium/High Temperature — 06Z

1-Gallon

Container

P903-2305

Medium/High Temperature — 06Z

5-Gallon

Container

Table 23 — VFD Drive Electric and Physical Data

PART NUMBER

VFD

OUTPUT

VOLTAGE

VFD (kW)

MCC OUTPUT

AT 45C

 (AMPS)

ENCLOSURE

RATING

WEIGHT (LBS)

DANFOSS

FUSE P/N

FUSE RATING

HR46ZY014

208/230

160

564

IP54

275

176F3174

800A 700V

HR46ZY030

IP20

HR46ZY006 & 027

380/460

110

212/190

IP54 & IP20

135

176F3171

350A 700V

HR46ZY006 & 028

132

260/240

IP54 & IP20

135

176F3171

350A 700V

HR46ZY008 & 031

160

315/302

IP54 & IP20

135

176F3172

400A 700V

HR46ZY010 & 021

200

395/361

IP54 & IP20

275

176F3173

550A 700V

HR46ZY011 & 022

250

480/443

IP54 & IP20

275

176F8335

630A 700V

HR46ZY019

315

588/535

IP20

275

176F3174

800A 700V

HR46ZY016

400

745/678

IP20

600

176F8592

900A 700V

HR46ZY018

450

800/730

IP20

600

176F8592

900A 700V

Содержание 06ZCE1H3AA06013

Страница 1: ...J Carlyle offers distinct versions of the vari able screw compressor for Medium High Temperature applica tions qualified with R 134a R 1234ze or R 513A refrigerants The following compressor features a...

Страница 2: ...capacity may be varied continuously to a lower limit of 22 of the economized compressor s full load capacity for air cooled applications VI CONTROL All 06Z models are supplied with a Vi control valve...

Страница 3: ...3 Fig 2 Compressor Physical Data and Connections 06ZC Frame 1...

Страница 4: ...4 Fig 2 Compressor Physical Data and Connections 06ZC Frame 1 cont...

Страница 5: ...5 Fig 3 Compressor Physical Data and Connections 06ZF Frame 2...

Страница 6: ...6 Fig 3 Compressor Physical Data and Connections 06ZF Frame 2 cont...

Страница 7: ...7 Fig 4 Compressor Physical Data and Connections 06ZJ Frame 3...

Страница 8: ...ISO 220 ASSEMBLY GREASE On occasion it may be necessary to use an assembly grease to re tain an O ring within its groove The following assembly grease is approved for use with the 06Z screwcompressor...

Страница 9: ...Reverse rotation is most likely to occur at initial start up or whenever the wiring to the compressor terminals is disturbed To minimize the possibility for reverse rotation operation Carlyle recommen...

Страница 10: ...Module package P N 6BSB000929 which provides the follow ing safety control functionality Discharge Temperature Monitoring Oil Level Monitoring Oil Flow Rate Supply Monitoring Table 3 Control Points S...

Страница 11: ...he a 500 watt flexible strip heater is recommended The heater should be wired to oper ate when the compressor is OFF This minimizes the migration of refrigerant to the oil stored in the sump Figure 6...

Страница 12: ...ith the following protocol networks BACnet1 Modbus2 N2 Open LonWorks3 requires optional card RS485 Communication Port If applying the Carlyle PCM module the accessories listed in Ta ble 5 are required...

Страница 13: ...13 PCM INPUTS OUTPUTS See Fig 9 for descriptions of the PCM Inputs and Outputs Fig 9 PCM Inputs and Outputs...

Страница 14: ...ssor off Motor Temperature Tm will have the following functions Control a motor cooling valve to provide liquid injection to the motor compartment Turn the compressor off on an overheated motor temper...

Страница 15: ...ON LED INDICATION OUTPUT 4 OUTPUT 5 COMPRESSOR MANUAL RESET REQUIRED HIGH DISCHARGE TEMPERATURE TRIP Solid red Opens De energized OFF Yes HIGH MOTOR TEMPERATURE TRIP Constant blinking Opens De energiz...

Страница 16: ...ERATURE 1 Compressor must be forced to Nominal Voltage as stated in Compressor Input Voltage 2 If operating at max speed reducing speed will allow motor to run on the rated V F curve if motor temperat...

Страница 17: ...17 Fig 13 Compressor Connection Details Fig 14 Sample Compressor Motor Voltage Curves...

Страница 18: ...95 Hz 25 Hz 98 Hz 618 787 865 380V 3 95 Hz 25 Hz 98 Hz 325 414 455 460V 3 95 Hz 25 Hz 98 Hz 269 342 377 06ZJ 325 Hp 380V 3 95 Hz 25 Hz 98 Hz 566 720 792 460V 3 95 Hz 25 Hz 98 Hz 468 596 655 Table 13 A...

Страница 19: ...of the compressor motor The thermistors are an NTC type with a standard resistance of 5000 ohms at 77 F 25 C All 06Z compressor motors are supplied with a spare thermistor to be used if the primary th...

Страница 20: ...GPM 06ZC 30XV50092301 Vertical 3 125 7 06ZF 30XV50122601 Vertical 4 125 7 06ZJ 30XV80004301 Horizontal 4 50 8 Table 19 Accessory Package PART NUMBER COMPRESSOR USAGE 06ZC 06ZF 06ZJ 06ZC660001 X 06ZF66...

Страница 21: ...store the compressors in doors where they are shielded from the weather Outdoor storage is permissible as long as temperatures stay within a temperature range of 40 F to 176 F 40 C to 80 C Weights an...

Страница 22: ......

Страница 23: ......

Страница 24: ...and without incurring obligations CARLYLE COMPRESSOR DIVISION 2022 Carrier P O Box 4808 Syracuse New York 13221 Phone 1 800 532 5031 Fax 1 315 432 3274 In U S and Puerto Rico 1 800 GO CARLYLE 1 800 46...

Отзывы: