BT2 Quick start operational guide
P a g e |
12
When the probe reaches the end of the hole, the last deployment interval will rarely equal the
full, user-defined
Segment length
. In this case, while the probe is at the end of the hole,
measure the distance from the hole collar back along the cable to the next measurement point,
i.e. the next interval / nodule / rod joint to which you would deploy if the hole were longer.
Recover the probe from the hole. A Bluetooth link is automatically re-established when the probe
is within range of the tablet. You may see some data being downloaded from the probe to
Carlson Boretrak
.
Enter the
Final Offset
.
The displayed
Length
is
adjusted accordingly.
Tap
Finish
to end
the deployment
Final Offset
Hole collar
The next nodule to
which you would
have deployed