background image

3

SECTION 2:  

Congratulations on choosing our product! Please  read all of this  instruction manual carefully and 

keep it safe for future reference.This manual contains all the necessary information for safe 

installation and operation of this product.

This equipment is produced in accordance with CE standards and conforms to international 

standard DMX512.  It can be operated in Master or Slave in phase control. This product is ideal for 

use with large architectural applications,entertainment, theatre,indoor or outdoor stages, etc.

On receiving this product, please carefully check that there has been no damage caused in 

transportation and that the following are enclosed: 

Signal   line  ----------------------- two pieces             User Manual----------------------- one copy

SECTION  3:  SAFETY INSTRUCTIONS

Every person involved with installation and maintenance of this device must be qualified 

and  follow the instructions of this manual

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY

BEFORE OPERATION

CAUTION:

Ø

K

eep this device away from rain and moisture!

Ø

U

nplug mains lead before opening the housing!

Ø

A

lways operate the equipment as described in the user manual

Ø

W

ith a high voltage you can suffer a dangerous electric shock when touching the 

wires!

Ø

T

his device has left our premises in absolutely perfect condition. In order to maintain this 

condition and to ensure safe operation, it is absolutely necessary for the user to follow 

the safety instructions and warning notes in this manual.

IMPORTANT:

Ø

T

he manufacturer will not accept liability for any resulting damages caused by the non-

observance of this manual or any unauthorized modification to the device.

Ø

Please consider that damages caused by manual modifications to the device are not 

subject to warranty.

Ø

Never allow the power-cable to come into contact with other cables! Always handle the 

power-cable and all electrical wiring and connections particular caution!

Ø

Make sure that the supplied voltage is not higher than stated on the rear panel.

Ø

Always ensure that the power-plug is securely connected. Make sure that the power-

switch is set to OFF-position before you connect the device to the mains. The power-

INTRODUCTION

www.carlosmendoza.com.mx

Содержание Showco Arc-Lite 575

Страница 1: ...Showco Arc Lite 575 www carlosmendoza com mx ...

Страница 2: ...TY INSTRUCTIONS Pg 3 5 LAMP REPLACEMENT Pg 5 6 SECURING THE FIXTURE Pg 5 7 POWERCONNECTIONS Pg 6 8 DMX512 CONNECTIONS Pg 6 9 CONTROLDIP SWITCH SETTINGS Pg 7 10 DMX512 MODE CHANNELASSIGNMENT Pg 9 13 ELECTRICALWIRING DIAGRAM Pg 11 15 MAINAINING AND CLEANING NOTICE Pg 13 4 11 TECNICAL SPECIFICATIONS Pg 10 12 PHOTOMETRIC DATA Pg 10 www carlosmendoza com mx ...

Страница 3: ...2 SECTION 1 PRODUCT DIAGRAM FRONT VIEW 446 410 445 7 289 2 SIDE VIEW 528 VERTICAL VIEW 126 POSITION ANGLE 428 289 2 326 396 80 150 344 254 100 100 BASE www carlosmendoza com mx ...

Страница 4: ...p this device away from rain and moisture Ø Unplug mains lead before opening the housing Ø Always operate the equipment as described in theuser manual Ø With a high voltage you can suffer adangerous electric shock when touching the wires Ø This device has leftour premises in absolutely perfect condition In order to maintainthis condition and to ensure safe operation it isabsolutely necessary for t...

Страница 5: ...mes very hot Ø When replacing lamps and fuses always use the same type and rating as specified in this user manual CAUTION AVOID EYE DAMAGE POWERFUL LIGHT SOURCE SECTION 4 GETTING STARTED Ø DO NOT turn onthe equipmentwithout thelamp Ø Prevent shaking Avoid strong vibration whenthe equipmentis installed Ø The minimum distance from the equipment to the illuminated object must be over 2 meters and ov...

Страница 6: ...directly at lamp when lit Warning INSIDE POWER SWITCH POWER SWITCH ON ON OFF OFF A B C D E Remove the lamp cover by turning screws D E Turn screws A B C anti clockwise to reduce the diameter of the light beam Turn screws A B C clockwise to increase the diameter of the light beam Turn screw C to adjust vertical position Turn screws A B to adjust horizontal position Fig 2 A B D E C Fig 3 SECTION 6 S...

Страница 7: ...earth wire must always be connected during operation of this unit Ø Wiring connections should be done correctly and in accordance with the standard in your local area COMMON WIRING CONNECTIONS DMX512 CONTROLLER 120 Attention Ø The last equipment sDMX signal output mustbe connectedwith acircuit plug Ø Connect one 120 Ohm resistor to the 3 pin plug s signal and signal Connect to the last equipment s...

Страница 8: ...H SETTINGS DMX512 MODE Switch 11 12 are OFF MASTER MODE Switch 11 is ON switch 12 is OFF SLAVE MODE Switch 11 is OFF switch 12 is ON When used with DMX512 the DMX ADDRESS is set using the first 10 DIP switches 1 2 3 4 1 7 13 19 1000000000 1110000000 1011000000 1100100000 LOOP ADDR BINARY USAGE OF DIP SWITCH 1 2 3 4 5 6 7 8 9 10 ON OFF 1 2 3 4 5 6 7 8 9 10 ON OFF 1 2 3 4 5 6 7 8 9 10 ON OFF 1 2 3 4...

Страница 9: ...0 10sec CH 21 30sec CH 22 60sec Red Orange Green Sky Blue Light Blue Dark Blue Purple Rose Red Pink Smooth Color Change CH 23 5sec CH 24 10sec CH 25 30sec CH 26 60sec White Red Orange Green Blue Light Blue Rose Red Rapid Color Change CH 27 5sec CH 28 10sec CH 29 30sec CH 30 60sec White Red Orange Green Blue Light Blue Rose Red Smooth Color Change CH 31 5sec CH 32 10sec CH 33 30sec CH 34 60sec Whit...

Страница 10: ...w Green Blue Light Blue Rose Red 10sec Smooth Color Change White Red Yellow Green Blue Light Blue Rose Red 5sec Rapid Color Change White Red Yellow Green Blue Light Blue Rose Red 60sec Rapid Color Change White Red Yellow Green Blue Light Blue Rose Red 30sec Rapid Color Change White Red Yellow Green Blue Light Blue Rose Red 10sec Rapid Color Change White Red Yellow Green Blue Light Blue Rose Red 5s...

Страница 11: ...MY Color mix System CMY color mixing withspeed control DIMMER 0 100 Linear Dimmer IP 54 4 5A 230V 40 Beampath SECTION 12 PHOTOMETRIC DATA 1 1 2 2 3 3 0 2900 7200 1250 500 400 320 620 LUX 5 3 10 15 20 25 30 3 64 2 18 7 28 10 92 14 56 18 20 21 84 40 4 4 5 5 6 6 Distance m Diameter m 7 Beampath 1 1 2 2 0 8200 23000 2300 800 620 560 1200 LUX 5 3 10 15 20 25 30 0 61 0 37 1 22 1 83 2 45 3 06 3 67 7 Dist...

Отзывы: