background image

Serie
Models

Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 090409 

1

Product Description

Ordering Key

• 12VDC, 24VDC, 48VDC system voltage
• 10A, 20A and 30A battery current ratings
• 8 automatic charging programs (bulk, float, equal)
• Charge LED status
• Load LED status
• Light / Load control
• Lighting set-up mode
• Battery Temperature Sensor (BTS)
• Manual / Auto Equalization

Type Selection

SBCLC 10A

SunBright

Solar Battery Charger

with Load Control

Electrical Data

SunBright is a solar battery
charger and a load/light control
device with an advanced design
using a microcontroller for
digital accuracy and fully
automatic operation. Each model
unit can be used for 12V, 24V and
48V system and can be operated
at three major functions including
solar charging, load control and
lighting control. 

The PWM battery charging has
been optimized for longer
battery life and the state-of-
the-art auto detector of day
and night has been precisely
applied to log the different
length of night hours for lighting
control no matter where and
when (the North or the South,
winter or summer) SunBright is
installed. 

Approvals

SBCLC 10A

Serie

SBCLC

Solar Battery Charger and
Load/Light Control

Models

10A

10A Current rating battery charge

20A

20A Current rating battery charge

30A

30A Current rating battery charge

Model

SBCLC 10A

SBCLC 20A

SBCLC 30A

System voltage ratings

12, 24, 48VDC

Current ratings - 
Battery Charge Control

10A

20A

30A

Current ratings - 
Load Control/Lighting Control

10A

20A

30A

Accuracy

12/24V: 0.1% ± 50mV - 48V: 0.1% ± 100mV

Min. / Max operating voltage

9V / 68V

Max. solar array Voc

140V

Current consumption

-25mA, (idle -3mA)

High temp shutdown

90ºC disconnect solar

90ºC disconnect load / diversion load

70ºC reconnect solar / load / diversion load

LVD 
(Low Voltage Disconnection)

11.1V (default), 10.5V, 11.3V, 11.5V, 11.7V, 11.9V, 12.1V, 12.3V for 

12V

system

22.2V (default), 20.1V, 22.6V, 23.0V, 23.4V, 23.8V, 24.2V, 24.6V for 

24V 

system

44.4V (default), 42.0V, 45.2V, 46.0V, 46.8V, 47.6V, 48.4V, 49.2V for 

48V 

system

LVR
(Low Voltage Reconnection)

12.6V (default), 12.0, 12.8V, 13.0V, 13.2V, 13.4V, 13.6V, 13.8V for 

12V 

system

25.2V (default), 24.0, 25.6V, 26.0V, 26.4V, 26.8V, 27.2V, 27.6V for 

24V 

system

50.4V (default), 48.0, 51.2V, 52.0V, 52.8V, 53.6V, 54.4V, 55.2V for 

48V 

system

Overload Capacity

150% of rated current for transient surge

Battery Charging/Built-in BTS Data

Model

SBCLC 10A

SBCLC 20A

SBCLC 30A

Charge algorithm

PWM (Pulse Width Modulation), constant voltage

Temp comp. coefficient

-5mV/ºC / cell (25ºC ref)

Temp comp. range

0ºC to +50ºC

Temp comp. setpoints

PWM, float, equalize (with BTS)

Отзывы: