3. Wiring diagrams
3 BU
2 WH
4 BK
1 BN
V
V
PIN
Color
Signal
Description
1
Brown
10 … 30 VDC
Sensor Supply
2
White
Load
Output 2 / SIO mode / External input / External Teach
3
Blue
GND
Ground
4
Black
Load
IO-Link /Output 1 /SIO mode
4. Commissioning
150 ms after the power supply is switched on, the sensor will be operational.
If it is connected to an IO-link master, no additional setting is needed and the IO-Link communication will start
automatically after the IO-Link master sends a wake-up request to the sensor.
2
3
1
4
NOTE!
The temperature measured by the sensor will always be higher than the ambient temperature, due to internal
heating.
The difference between ambient temperature and internal temperature is influenced by how the sensor is
installed in the application. If the sensor is installed in a metal bracket the difference will be lower than if the
sensor is mounted in a plastic one.