2
Specifications are subject to change without notice (06.08.2008)
+
-
1 BN
3 BU
4 BK
Teach-in
5 PK
(GY)
5
3
2
1
4
M18 and M30
Analogue Output Adjustment
1
2
3
4
5
Echo P1 P2
Green Yellow Yellow
Teach in of P1 position
Teach in of P2 position
Teach-In for
8 sec
14 sec
Normal function:
The Echo LED is ON when the echo is received (this is the
alignment LED confirming that the target is properly aligned).
The LED P1 is ON, when the target is between the sensor
face and P1. The LED P2 is ON when Target is farther than
P2.
Wiring Di a gram
Teach-In for
14 sec
Linearity error
< 0.5%
Repeat accuracy
(R)
UA....D05/08 0.2%; 1 mm
UA....D20/35 0.2%: 2 mm
Rated operating distance/
Resolution*
UA18CLD05 60-500 mm: 0.25 mm
UA18CLD08 100-800 mm: 0.25 mm
UA18CLD20 200-2000 mm: 1.0 mm
UA30CLD35 300-3500 mm: 1.0 mm
Load
4-20 mA max. 500 Ω
0-10 V min. 1 kΩ
Carrier frequency
UA....D05 330 KHz
UA....D08 300 KHz
UA....D20 180 KHz
UA....D35 130 KHz
Response time
UA18CLD05/08 100 ms
UA18CLD20 200 ms
UA30CLD35 400 ms
Technical Data (cont.)
Indication
Set points, 2 LEDs yellow
Echo, 1 LED green
Rated operating distance
60 - 3500 mm
Temperature compensation
Yes
Beam angle
8°
Ambient temperature
Operating and Storage -15° to +70°C (5° to +158°F)
Degree of protection
IP 67 (Nema 1, 3, 4, 6, 13)
Housing material
Polyester, PBTP
Connection
Cable
2 m, 5 x 0.25 mm
2
Plug
M12, 5-pin
Cables for plug (M1)
CONM15 series
WeightWeight
UA 18 ...A. 96 g
UA 18 ...A.M1 57 g
UA 30 ...A. 199 g
UA 30 ...A.M1 140 g
Tightening torque
M18 2.6 Nm
M30 7.5 Nm
CE-marking
Yes