background image

Specifications are subject to change without notice (19.09.2016) 

Bottom part: mounted in ceiling

GP62x0 22xx 724-US

Programmable connector

for GP 7380 0080

Power

D+

D-

Power

D+
D-

X
Y

To other 

sensors

To other 

sensors

Wiring Diagram

Note: The 2 x 3 pin connector are internally connected on 

the PCB.

Note: X and Y is not in use for model number GP6220 2201 

724-US and GP6220 2202 724-US

NOTE:

 The wiring of the sensors must always be made with 

1.5 mm

2

 single core wire

Only in use for 

GP6240 2224 724-US

Programmable connector

for GP 7380 0080

Pow

D+

D-

Pow

D+ D-

X
Y

Not in use

X
Y

GP6240 2224 724-US

GP6289 000x-US

Connection diagram

EXIT

ENTRANCE

A1

A2

A4

A3

Two sensor option

Example of a sensor in a count installation

Содержание GP62x022xx724-US Series

Страница 1: ...lable for parking A red LED indicates that the Product Description Ordering key GP 62x0 22xx 724 US RJ12 connector for address programming with Carpark Configurator GP7380 0080 2x3 pin connector Printed dot on the sensor is Dupline D or Gnd POW power from DMM or Coupler See drawing on page 3 System diagram 1x2 pin connector Not in use for Carpark sensors GP6220 220x 724 US Only in use for GP6240 2...

Страница 2: ... apply for the assignment Calibration Dupline address This address is used to trig ger the sensor to perform a self calibration Several sen sors can be given the same calibration address thereby making it possible to cal ibrate multiple sensors at once by sending a single trig ger signal on that address The programming unit GP73800080 is used to send out the trigger signal Modes The sensor has two...

Страница 3: ...calibration of the single sensor Push the button on the out side of the sensor The LED flashes green for 30 seconds with 1 Hz The electrician has time to get clear of the sensor before the calibration starts The calibration starts when the LED flashes green for 6 seconds with 4 Hz If the calibration is OK the LED will respond with a constant green light Automatic calibration with the Carpark Confi...

Страница 4: ... DMM GP34960005700 System Diagram NOTE The DMM on L1 must be the type GP3496 0005 700 The DMM on L2 must be an another type We recommend the G3496 0005 700 because of the modbus RTU protocol Parking bay Sensor 1 Lane Parking bay Sensor 2 Parking bay Sensor 3 Fig 1 Parking bay Sensor 1 Lane Parking bay Sensor 2 Parking bay Sensor 3 Fig 2 Lane senor LED indicator Fig 1 and Fig 2 The sensors can be u...

Страница 5: ...or are internally connected on the PCB Note X and Y is not in use for model number GP6220 2201 724 US and GP6220 2202 724 US NOTE The wiring of the sensors must always be made with 1 5 mm2 single core wire Only in use for GP6240 2224 724 US Programmable connector for GP 7380 0080 Pow D D Pow D D X Y Not in use X Y GP6240 2224 724 US GP6289 000x US Connection diagram EXIT ENTRANCE A1 A2 A4 A3 Two s...