background image

Control the bag of used powders every 4/5 days and replace it before completely full (max 
to approximately 2/3 of its capacity). Do not  re-use and do not  empty out the used filters. 
When the filter is exausted  close it with a proper adhesive tape and waste appropiately in 
compliance with your country rules.  

Check every two weeks the motor protection filter and clean it by blowing compressed air 
in the same way of passage of the sucked air. The filter must be replaced with a new one 
at  least  every    4  months.  This  preserves  the  motor  and  the  perfect  operating  of  the 
apparatus.  

1. Control that the power cord plug (rif. 13) is properly connected to the electrical outlet.

1. Replace the recovery dust filter (rif.10), and/or replace the motor protection filter (rif.7-

8-9).

Carried out these controls, in case the apparatus still presents disadvantages, contact the 
customers’ technical service.  

Operating voltage V/Hz 230/50-60 (see nameplate on the apparatus) 
Weight Kg. 3,5 

Height cm. 25 Width cm. 29 Depth cm. 25 