PARTS IDENTIFICATION
Toggle 1
JOB number selected:
69
GUNs Masked to accept JOB #69:
1,3
Toggle 2
JOB number selected:
26
GUNs Masked to accept JOB #26:
2,5,8
Toggle 3
JOB number selected:
63
GUNs Masked to accept JOB #63:
NONE
Toggle 4
JOB number selected:
22
GUNs Masked to accept JOB #22:
4
Figure 6 shows 4 Toggle Signals. By following the dashed
line down you can determine the states of the various sig-
nals for each example. Maintained inputs that are high are
“active”. Pulsed signals that go high at that instance are
also active. The list to the left will help explain what JOB
number is selected, and to which of the 8 GUN queues the
JOB is entered into.
4 EXAMPLES OF SIGNAL SEQUENCING
Figure 6: JOB Selection Timing Diagram Sample
LN-9400-00-R11 (08/2018)
47 / 96
www.carlisleft.com